MIS06-00005
| MIS-Aging Inspection | 9/18/2006 | 9/18/2006 | 9/19/2006 10:25:57 AM | | CANC |
|
|
|
MIS06-00006
| MIS-Aging Inspection | 9/18/2006 | 9/18/2006 | 9/19/2006 10:25:45 AM | | CANC |
|
|
|
BLD06-01728
| BLD-Aging Inspection | 9/18/2006 | 9/18/2006 | 9/19/2006 10:25:17 AM | | NR |
|
|
Drove by, it appears that sighn has not yet been remmoved.
|
BLD04-03025
| BLD-Framing/Rough-in | 9/18/2006 | 9/18/2006 | 9/18/2006 4:44:37 PM | P | NR |
|
|
Scheduled by a contractor via Hello! on 9/18/2006 at 7:41:50 AM. Contact: ###-####.
|
BLD06-02588
| BLD-Footing | 9/18/2006 | 9/18/2006 | 9/18/2006 3:29:34 PM | P | PART |
|
|
Scheduled by a contractor via Hello! on 9/18/2006 at 9:08:07 AM. Contact: ###-####.wip.
|
BLD06-01463
| BLD-Conference | 9/18/2006 | 9/18/2006 | 9/18/2006 3:15:44 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 9/18/2006 at 8:21:46 AM. Contact: ###-####.
|
BLD06-01437
| BLD-Framing/Rough-in | 9/18/2006 | 9/18/2006 | 9/18/2006 2:40:30 PM | P | PASS |
|
|
ramiz; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. Homeowner has obtained engineering services and made the required repairs. ok to insul. airseal package not completed.
|
BLD06-02483
| BLD-Foundation | 9/18/2006 | 9/18/2006 | 9/18/2006 2:17:20 PM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 9/18/2006 at 9:31:01 AM. Contact: ###-####. Setbacks incorrect. Permit shows 15 ft setback required at rear. only has 9 ft. contractor on site and was notified. Also no footing schedule.
|
BLD06-02441
| BLD-Footing | 9/18/2006 | 9/18/2006 | 9/18/2006 1:51:48 PM | P | PART |
|
|
mike ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley. wip.
|
BLD06-01466
| BLD-Framing/Rough-in | 9/18/2006 | 9/18/2006 | 9/18/2006 1:42:32 PM | P | PASS |
|
|
dan - roof nailing; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley. Roof shear nailing ok. ( staples used at 4 & 6)
|
MIS06-00245
| BLD-Final | 9/15/2006 | 9/18/2006 | 9/18/2006 11:03:21 AM | A | PASS |
|
|
jerry -call prior for access (late am); Phone #: ###-#### Internet Inspection Request from: Barbara Buckley. ok for perm occ.
|
BLD05-02086
| BLD-Framing/Rough-in | 9/15/2006 | 9/18/2006 | 9/18/2006 10:28:44 AM | A | FAIL |
|
|
tom ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley. Needs to provide truss engineering, complete airseal package. Needs to provide additional header upstairs at truss bearing, add 2x6 at rafters, needed to be 2x10. provide straps at ml header and top plate at lineset. Also needs to install the additional 2x4 studs down stairs on either side of windows as noted on approved plans.
|
BLD06-01088
| BLD-Final | 9/15/2006 | 9/18/2006 | 9/18/2006 9:26:28 AM | A | NR |
|
|
jeff; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles. No accesss. tried to call contact number. no awnser.
|
BLD06-00956
| BLD-Final | 9/15/2006 | 9/18/2006 | 9/18/2006 9:19:45 AM | A | PASS |
|
|
jeff; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
BLD06-00956
| DOC - Permit Finaled | 9/18/2006 | 9/18/2006 | 9/18/2006 9:19:36 AM | P | PASS |
|
|
All items corrected.
|