Inspections for the day of: Tuesday, September 18, 2007.
Number of inspections: 11
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-01919 Final9/18/20079/18/20079/18/2007 3:37:00 PMPPASS
CONTACT JACK
Phone #: ###-#### Internet Inspection Request from: Emmet Bushman ok
ELE07-03228 Electrical Rough-In9/17/20079/18/20079/18/2007 2:53:49 PMPPART
POOL BONDING Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack pool re-bar only no u/g or Egrid
ELE07-03069 Rough-In Permanent Service9/18/20079/18/20079/18/2007 2:25:29 PMPPASS
underground-3 sections and p/s --roger Phone #: ###-#### u/g ok make sure nothing foreign to electrical not allowed under panels p/s u/g new ok
ELE07-03244 Electrical Rough-In9/18/20079/18/20079/18/2007 1:29:06 PMPPART
emmett - pool bonding Phone #: ###-####
bottom of pool re-bar and stainless side panels bonded only no u/g or E grid, or pool light
ELE07-02309 Electrical Rough-In9/17/20079/18/20079/18/2007 1:13:59 PMPPART
Roger Reynolds contact ###-#### Thank You Phone #: ###-#### Internet Inspection Request from: Debby Ellis walls and hard ceilings anop ok
ELE07-03064 Electrical Rough-In9/18/20079/18/20079/18/2007 10:51:05 AMAFAIL
CONTACT JACK Phone #: ###-#### Internet Inspection Request from: Emmet Bushman corr. 250.122 20 amp #12 circuit needs #12 grd pigtail 3gang bottom stairs, 314.43 remove nails outside back outlet from inside of box, 300.4(A)(1) nail plates inside outside edges BCC install recept box upstairs bath by sink
ELE07-01569 Final9/17/20079/18/20079/18/2007 10:14:39 AMAFAIL
garage door jayo-enter Phone #: ###-#### Internet Inspection Request from: Joseph Zumwalt corr 110.3(B) shall follow manufacture's instructions for j tub 15m amp max breaker and 24"x24" minimum access 406.4 loose recepts baht rm mirror outlets, 314.20 M bed rm outlet by door needs box extension, 314.17(A&B) install flex conn into box island counter
ELE07-02529 Final9/17/20079/18/20079/18/2007 9:02:25 AMAPASS
Final Inspection. Please call Pete @ ###-#### or AJ @ ###-#### Phone #: ###-#### Internet Inspection Request from: todd hall 2 rms locked ok card signed
ELE07-03147 Electrical Rough-In9/17/20079/18/20079/18/2007 8:35:26 AMAPASS
Phone #: ###-#### Internet Inspection Request from: BRENDA HURST ok
ELE07-03147 Final9/18/20079/18/20079/18/2007 8:35:12 AMAPASS
Phone #: ###-#### Internet Inspection Request from: BRENDA HURST ok
ELE07-02104 Final9/18/20079/18/20079/18/2007 8:03:30 AMAPASS
ok