Inspections for the day of: Thursday, September 18, 2008.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Sly
TitleBLD-COM/RES INSPECTOR
Phone #794-9465
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD08-00424 BLD-Energy code compliance9/17/20089/18/20089/18/2008 5:37:13 PMPPASS
jake Phone #: ###-####
ESC08-00713 Site Final9/18/20089/18/20089/18/2008 5:36:29 PMPPASS
BLD08-01822 BLD-Final9/18/20089/18/20089/18/2008 5:36:03 PMPPASS
Curt- call 30 mins prior to going Phone #: ###-####
BLD08-01822 DOC - Permit Finaled9/18/20089/18/20089/18/2008 5:35:49 PMPPASS
BLD08-01987 BLD-Footing9/17/20089/18/20089/18/2008 5:35:26 PMPPASS
chancey Phone #: ###-####
BLD08-01863 BLD-Conference9/18/20089/18/20089/18/2008 4:46:24 PMPDONE
Cindy ###-####
Met with Mike (owner)....Mike had concerns about a 16" x 16" x 8" pier block installed in crawlspace under new beam point load. Mike feels that it might be too small so I advised to have a design specialist or Struct Engineer calc out the load and install new footing per their specifications. Mike and I pulled a string line across ceiling (approx 18') in the area of the point load and it appeared to be sagging 1/4"
BLD08-01958 BLD-Foundation9/18/20089/18/20089/18/2008 2:13:14 PMPPASS
Dylan Phone #: ###-####
BLD08-01945 BLD-Concrete9/18/20089/18/20089/18/2008 1:36:08 PMPPASS
dan Phone #: ###-####
BLD08-01263 BLD-Final9/17/20089/18/20089/18/2008 12:03:55 PMAPASS
Madison ###-####
BLD08-01263 DOC - Permit Finaled9/18/20089/18/20089/18/2008 12:03:34 PMPPASS
BLD08-01064 BLD-Final9/17/20089/18/20089/18/2008 12:03:12 PMAPASS
Ken ###-####
BLD08-01064 DOC - Permit Finaled9/18/20089/18/20089/18/2008 12:03:00 PMPPASS
BLD08-00932 BLD-Framing/Rough-in9/17/20089/18/20089/18/2008 12:02:27 PMAPART
Bob Phone #: ###-####
C/N Duct through 1hr wall
BLD06-02320 BLD-Wall cover9/17/20089/18/20089/18/2008 11:24:55 AMAFAIL
I would like to inspect 1st floor bldg 3 units to insulate and sheetrock. Phone #: ###-#### Internet Inspection Request from: Bob Thornton
Looked at 4 unit in Bldg #3.....Need all UL listings for all trade.... ceiling and wall penitrations...... Need listing for protection pads on plumbing washer boxes.....Dryer box and ducting in 1hr wall....Architect to address......OK to insulate and add channel to ceiling only......Check for fireblocking at double walls (at ceiling line).
BLD08-00567 BLD-Other9/18/20089/18/20089/18/2008 9:26:16 AMADONE
Scheduled by a contractor via Hello! on 9/18/2008 at 6:47:48 AM. Contact: ###-####.
Talked to Contr....Need detail and UL listing from Architect for 1hr wall / roof deck to maintain 1hr rating.