ELE12-01385
| ELE-Aging Inspection | 9/18/2014 | 9/18/2014 | 9/18/2014 4:29:23 PM | | DONE |
|
|
waiting on owner
|
ELE14-02614
| Rough-In Permanent Service | 9/17/2014 | 9/18/2014 | 9/18/2014 4:18:54 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI Rough in ok cover p/s u/g n ok
|
ELE14-01828
| Final | 9/18/2014 | 9/18/2014 | 9/18/2014 3:39:49 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
ELE14-01747
| Final | 9/18/2014 | 9/18/2014 | 9/18/2014 3:16:15 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
|
ELE14-02573
| Permanent Service | 9/17/2014 | 9/18/2014 | 9/18/2014 2:26:14 PM | P | PASS |
|
|
please call before arrival much work to be done thank you very much Phone #: ###-#### Inspection requested via web by shane miller p/s o/h rec ok
|
ELE14-01452
| Final | 9/18/2014 | 9/18/2014 | 9/18/2014 2:02:09 PM | P | FAIL |
|
|
code 1998, if needed box is on side door Phone #: ###-#### Inspection requested via web by cal crosby 356.30 Securing and Supporting. Type LFNC-B shall be securely fastened and supported in accordance with one of the following: (1) Where installed in lengths exceeding 1.8 m (6 ft), the conduit shall be securely fastened at intervals not exceeding 900 mm (3 ft) and within 300 mm (12 in.) on each side of every outlet box, junction box, cabinet, or fitting. AC whip. 200.7(C) Circuits of 50 Volts or More. The use of insulation that is white or gray or that has three continuous white or gray stripes for other than a grounded conductor for circuits of 50 volts or more shall be permitted only as in (1) and (2). (1) If part of a cable assembly that has the insulation permanently reidentified to indicate its use as an ungrounded conductor by marking tape, painting, or other effective means at its termination and at each location where the conductor is visible and accessible. 440.4 Marking on Hermetic Refrigerant Motor- Compressors and Equipment. (C) Branch-Circuit Selection Current. A hermetic refrigerant motor-compressor, or equipment containing such a compressor, having a protection system that is approved for use with the motor-compressor that it protects and that permits continuous current in excess of the specified percentage of nameplate rated-load current given in 440.52(B)(2) or (B)(4) shall also be marked with a branch-circuit selection current that complies with 440.52(B)(2) or (B)(4). This marking shall be provided by the equipment manufacturer and shall be on the nameplate(s) where the rated-load current( s) appears. 110.12 Mechanical Execution of Work. Electrical equipment shall be installed in a neat and workmanlike manner. Informational Note: Accepted industry practices are described in ANSI/NECA 1-2010, Standard Practice of Good Workmanship in Electrical Construction, and other ANSIapproved installation standards. (A) Unused Openings. Unused openings, other than those intended for the operation of equipment, those intended for mounting purposes, or those permitted as part of the design for listed equipment, shall be closed.
|
ELE14-01391
| Electrical Rough-In | 9/18/2014 | 9/18/2014 | 9/18/2014 1:29:59 PM | P | PASS |
|
|
In the back of the house we ran a conduit for the pond. Phone #: ###-#### Inspection requested via web by Neal Rumsey Underground back of house to pond rough in ok cover
|
ELE14-02616
| Electrical Rough-In | 9/18/2014 | 9/18/2014 | 9/18/2014 12:57:43 PM | P | PASS |
|
|
Soffits only Phone #: ###-#### Inspection requested via web by Jay Symonds Soffits only rough in ok cover
|
ELE14-02595
| Permanent Service | 9/17/2014 | 9/18/2014 | 9/18/2014 12:31:16 PM | P | PASS |
|
|
If you have any questions, please call our office. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan Panel outdoors next to meter in back of house. change and upgrade grounding. water pipe in basement front of house. p/s o/h rec ok
|
ELE14-02237
| Final | 9/17/2014 | 9/18/2014 | 9/18/2014 12:06:38 PM | A | NH |
|
|
Phone #: ###-#### Inspection requested via web by Matthew White Door locked no answer call will reschedule
|
ELE14-01894
| Final | 9/17/2014 | 9/18/2014 | 9/18/2014 10:13:09 AM | A | PASS |
|
|
15-20 min notice to meet // Ron Alexander Phone #: ###-#### Final ok
|
ELE14-02484
| Electrical Rough-In | 9/17/2014 | 9/18/2014 | 9/18/2014 9:24:20 AM | A | PASS |
|
|
Todd Phone #: ###-#### Unser slab around perimeter of foundation rough in ok cover
|
ELE14-02537
| Final | 9/17/2014 | 9/18/2014 | 9/18/2014 8:58:56 AM | A | FAIL |
|
|
Need inspection for power to be restored after being off more than 1 year. Door code is 2229. Home is vacant Phone #: ###-#### Inspection requested via web by Randy Fletcher 250.53 Grounding Electrode System Installation (2) Supplemental Electrode Required. A single rod, pipe, or plate electrode shall be supplemented by an additional electrode of a type specified in 250.52(A)(2) through (A)(8). The supplemental electrode shall be permitted to be bonded to one of the following: (1) Rod, pipe, or plate electrode (2) Grounding electrode conductor (3) Grounded service-entrance conductor (4) Nonflexible grounded service raceway (5) Any grounded service enclosure Section 4-05-32 CODE VIOLATION NOT TO BE RETAINED. For final exposed wiring on west side of house shall be removed or replaced. An AC disconnedt shall be installed. Called number provided, no answer, voice mail has not been set up yet.
|