Inspections for the day of: Thursday, September 18, 2014.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-01385 ELE-Aging Inspection9/18/20149/18/20149/18/2014 4:29:23 PM DONE
waiting on owner
ELE14-02614 Rough-In Permanent Service9/17/20149/18/20149/18/2014 4:18:54 PMAPASS
Phone #: ###-#### Inspection requested via web by TOM BICANDI Rough in ok cover p/s u/g n ok
ELE14-01828 Final9/18/20149/18/20149/18/2014 3:39:49 PMPPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
ELE14-01747 Final9/18/20149/18/20149/18/2014 3:16:15 PMPPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn Final ok
ELE14-02573 Permanent Service9/17/20149/18/20149/18/2014 2:26:14 PMPPASS
please call before arrival much work to be done thank you very much Phone #: ###-#### Inspection requested via web by shane miller p/s o/h rec ok
ELE14-01452 Final9/18/20149/18/20149/18/2014 2:02:09 PMPFAIL
code 1998, if needed box is on side door Phone #: ###-#### Inspection requested via web by cal crosby 356.30 Securing and Supporting. Type LFNC-B shall be
securely fastened and supported in accordance with one of
the following:
(1) Where installed in lengths exceeding 1.8 m (6 ft), the
conduit shall be securely fastened at intervals not exceeding
900 mm (3 ft) and within 300 mm (12 in.) on each
side of every outlet box, junction box, cabinet, or fitting. AC whip.
200.7(C) Circuits of 50 Volts or More. The use of insulation
that is white or gray or that has three continuous white or
gray stripes for other than a grounded conductor for circuits
of 50 volts or more shall be permitted only as in (1) and (2).
(1) If part of a cable assembly that has the insulation permanently
reidentified to indicate its use as an ungrounded
conductor by marking tape, painting, or other
effective means at its termination and at each location
where the conductor is visible and accessible.
440.4 Marking on Hermetic Refrigerant Motor-
Compressors and Equipment. (C) Branch-Circuit Selection Current. A hermetic refrigerant
motor-compressor, or equipment containing such a
compressor, having a protection system that is approved for
use with the motor-compressor that it protects and that permits
continuous current in excess of the specified percentage
of nameplate rated-load current given in 440.52(B)(2)
or (B)(4) shall also be marked with a branch-circuit selection
current that complies with 440.52(B)(2) or (B)(4). This
marking shall be provided by the equipment manufacturer
and shall be on the nameplate(s) where the rated-load current(
s) appears.
110.12 Mechanical Execution of Work. Electrical equipment
shall be installed in a neat and workmanlike manner.
Informational Note: Accepted industry practices are described
in ANSI/NECA 1-2010, Standard Practice of Good
Workmanship in Electrical Construction, and other ANSIapproved
installation standards.
(A) Unused Openings. Unused openings, other than those
intended for the operation of equipment, those intended for
mounting purposes, or those permitted as part of the design
for listed equipment, shall be closed.
ELE14-01391 Electrical Rough-In9/18/20149/18/20149/18/2014 1:29:59 PMPPASS
In the back of the house we ran a conduit for the pond. Phone #: ###-#### Inspection requested via web by Neal Rumsey Underground back of house to pond rough in ok cover
ELE14-02616 Electrical Rough-In9/18/20149/18/20149/18/2014 12:57:43 PMPPASS
Soffits only Phone #: ###-#### Inspection requested via web by Jay Symonds Soffits only rough in ok cover
ELE14-02595 Permanent Service9/17/20149/18/20149/18/2014 12:31:16 PMPPASS
If you have any questions, please call our office. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan Panel outdoors next to meter in back of house. change and upgrade grounding. water pipe in basement front of house. p/s o/h rec ok
ELE14-02237 Final9/17/20149/18/20149/18/2014 12:06:38 PMANH
Phone #: ###-#### Inspection requested via web by Matthew White Door locked no answer call will reschedule
ELE14-01894 Final9/17/20149/18/20149/18/2014 10:13:09 AMAPASS
15-20 min notice to meet // Ron Alexander Phone #: ###-#### Final ok
ELE14-02484 Electrical Rough-In9/17/20149/18/20149/18/2014 9:24:20 AMAPASS
Todd Phone #: ###-#### Unser slab around perimeter of foundation rough in ok cover
ELE14-02537 Final9/17/20149/18/20149/18/2014 8:58:56 AMAFAIL
Need inspection for power to be restored after being off more than 1 year. Door code is 2229. Home is vacant Phone #: ###-#### Inspection requested via web by Randy Fletcher
250.53 Grounding Electrode System Installation (2) Supplemental Electrode Required. A single rod, pipe,
or plate electrode shall be supplemented by an additional
electrode of a type specified in 250.52(A)(2) through
(A)(8). The supplemental electrode shall be permitted to be
bonded to one of the following:
(1) Rod, pipe, or plate electrode
(2) Grounding electrode conductor
(3) Grounded service-entrance conductor
(4) Nonflexible grounded service raceway
(5) Any grounded service enclosure
Section 4-05-32 CODE VIOLATION NOT TO BE RETAINED. For final exposed wiring on west side of house shall be removed or replaced.
An AC disconnedt shall be installed.
Called number provided, no answer, voice mail has not been set up yet.