PLM17-03550
| Final | 9/18/2017 | 9/18/2017 | 9/18/2017 3:17:39 PM | P | CANC |
|
|
Michael-water softner Phone #: ###-####-Contractor who installed softner needs to pull permit.
|
PLM17-03185
| Plumbing Rough-in | 9/15/2017 | 9/18/2017 | 9/18/2017 3:04:19 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Brian Johansen-DWV & water test fail.
|
PLM17-03553
| Sprinkler (Final) | 9/18/2017 | 9/18/2017 | 9/18/2017 2:48:52 PM | P | PASS |
|
|
Genaro Phone #: ###-####
|
PLM17-03553
| DOC - Permit Finaled | 9/18/2017 | 9/18/2017 | 9/18/2017 2:48:42 PM | P | PASS |
|
|
|
PLM17-03468
| Plumbing Rough-in | 9/18/2017 | 9/18/2017 | 9/18/2017 2:28:45 PM | P | PASS |
|
|
Call Kevin ###-#### Phone #: ###-#### Inspection requested via web by Kevin Smith
|
PLM17-03546
| Plumbing Rough-in | 9/18/2017 | 9/18/2017 | 9/18/2017 2:23:13 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Samuel Drake-Need to fix backgraded vent in laundry room. Trap arm for toilet can only be 6'. Need to finish rough-in. Need to replace mission band with no-hub band.
|
MEC17-03161
| Rough-in | 9/15/2017 | 9/18/2017 | 9/18/2017 1:42:26 PM | P | PASS |
|
|
Field Super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
|
MEC17-03161
| Pressure Test | 9/15/2017 | 9/18/2017 | 9/18/2017 1:42:13 PM | P | CANC |
|
|
Field Super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
|
MEC17-02581
| Final | 9/18/2017 | 9/18/2017 | 9/18/2017 1:21:37 PM | P | FAIL |
|
|
Will Phone #: ###-####-Need to provide access to gas valve to fireplace so it is not concealed and has access for operation. Need UV protection on linesets at A/C'c.
|
PLM17-03525
| Final | 9/18/2017 | 9/18/2017 | 9/18/2017 12:43:02 PM | P | NH |
|
|
Call Donna Woods at ###-#### x 2905 for directions if needed Phone #: ###-#### Inspection requested via web by Mary LaFayette-No access, left notice.
|
PLM16-03063
| Final | 9/18/2017 | 9/18/2017 | 9/18/2017 11:25:24 AM | A | PART |
|
|
Condos on north side are ready for final inspection Phone #: ###-#### Inspection requested via web by Brent Lacy-All T&P's require an air gap above hub drains.
|
PLM17-03455
| Final | 9/13/2017 | 9/18/2017 | 9/18/2017 11:07:20 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Mary LaFayette
|
MEC17-04179
| Pressure Test | 9/15/2017 | 9/18/2017 | 9/18/2017 10:10:47 AM | A | FAIL |
|
|
Call Jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek-5 lb flue test for furnace fail. 5 lb flue test for w/h pass. 20 lb gas test pass.
|
MEC17-04179
| Rough-in | 9/15/2017 | 9/18/2017 | 9/18/2017 10:09:20 AM | A | PASS |
|
|
Call Jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek
|
PLM17-00980
| Final | 9/16/2017 | 9/18/2017 | 9/18/2017 9:50:05 AM | A | PASS |
|
|
Garage code 1001 lock button. Phone #: ###-#### Inspection requested via web by David Stephenson
|
MEC17-04093
| Rough-in | 9/15/2017 | 9/18/2017 | 9/18/2017 9:01:57 AM | A | PASS |
|
|
mechanical fireplace rough in inspection Phone #: ###-#### Inspection requested via web by Dan Otero
|
PLM17-02690
| Final | 9/15/2017 | 9/18/2017 | 9/18/2017 8:52:25 AM | A | PASS |
|
|
Garage code 1001 lock button. Phone #: ###-#### Inspection requested via web by David Stephenson
|
PLM17-03468
| Plumbing Rough-in | 9/15/2017 | 9/18/2017 | 9/18/2017 8:16:10 AM | A | FAIL |
|
|
Call Kevin ###-#### Phone #: ###-#### Inspection requested via web by Kevin Smith-Need to fix backgraded vent in wall between back to back baths and missing nailplates.
|
PLM17-03468
| Plumbing Rough-in | 9/15/2017 | 9/18/2017 | 9/18/2017 6:21:15 AM | A | CANC |
|
|
|
PLM16-02693
| PLM-Aging Inspection | 9/18/2017 | 9/18/2017 | 9/18/2017 6:18:23 AM | | PART |
|
|
No calls
|