MEC18-04193
| Final | 9/18/2018 | 9/18/2018 | 9/18/2018 4:22:38 PM | P | FAIL |
|
|
Final - call RJ 30 minutes before arrival Phone #: ###-#### Inspection requested via web by Brandon Sorensen- 20lb gas pressure test ok- wet switch ok- co detectors ok- lineset penetration ok- electrical conduit for A/C ok- - need to add other to permit for duct work in addition
|
MEC18-04367
| Final | 9/18/2018 | 9/18/2018 | 9/18/2018 3:42:01 PM | P | PASS |
|
|
INSTALLER AL ###-#### Inspection requested via web by Aaron Alandt- furnace ac coil co ok
|
MEC18-04233
| Final | 9/17/2018 | 9/18/2018 | 9/18/2018 2:45:02 PM | P | PASS |
|
|
Please call journeyman Bob Herndon ###-#### when in route-- unit will be under test Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace ac coil co ok
|
MEC18-04233
| Pressure Test | 9/17/2018 | 9/18/2018 | 9/18/2018 2:44:42 PM | P | PASS |
|
|
Please call journeyman Bob Herndon ###-#### when in route-- unit will be under test Phone #: ###-#### Inspection requested via web by Justin Osterhout- 5lb flue pressure test ok
|
MEC18-02476
| Final | 9/18/2018 | 9/18/2018 | 9/18/2018 2:43:52 PM | P | FAIL |
|
|
105,106,205,206,305,306 Phone #: ###-#### Inspection requested via web by Gary Reeves- all duct blasts ok- 106 has a hole in the return duct work that needs sealed- back draft damper outside is broken- 205- lineset insulation needs fixed and a transfer grille is missing- 206 lineset insulation needs fixed- 305 lineset insulation needs fixed-
|
MEC18-04522
| Rough-in | 9/18/2018 | 9/18/2018 | 9/18/2018 1:56:03 PM | P | FAIL |
|
|
Shaun: ###-#### Phone #: ###-#### Inspection requested via web by Frank Marturello -duct seal on return 1st floor needs sealed on vertical seams- one flex run upstairs in bonus room is pinched between framing
|
MEC18-04522
| Pressure Test | 9/18/2018 | 9/18/2018 | 9/18/2018 1:54:53 PM | P | PASS |
|
|
Shaun: ###-#### Phone #: ###-#### Inspection requested via web by Frank Marturello -20lb gas pressure test ok- 5lb flue pressure test ok
|
MEC18-01752
| Final | 9/18/2018 | 9/18/2018 | 9/18/2018 1:54:53 PM | P | PASS |
|
|
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney - final ok
|
MEC18-04482
| Rough-in | 9/17/2018 | 9/18/2018 | 9/18/2018 12:01:25 PM | A | FAIL |
|
|
Anytime! Inspection requested via web by Floyd Floyd Peek- pressure test fail- water heater b vent needs 1" clearances- equipment was not set at R/I need to check at final
|
MEC18-04482
| Pressure Test | 9/17/2018 | 9/18/2018 | 9/18/2018 11:59:07 AM | A | FAIL |
|
|
Anytime! Inspection requested via web by Floyd Floyd Peek- no pressure on the gas line and the gauge was stuck on 30lb
|
MEC18-04347
| Rough-in | 9/17/2018 | 9/18/2018 | 9/18/2018 11:58:03 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- pressure test not ready- supply trunk needs sealed at furnace- supply trunk upstairs needs sealed- seal all exhaust fans- water heater b vent upstairs needs 1" clearances on the roof
|
MEC18-04347
| Pressure Test | 9/17/2018 | 9/18/2018 | 9/18/2018 11:56:41 AM | A | NR |
|
|
Phone #: ###-#### Inspection requested via web by Gary Reeves- not ready
|
MEC18-04430
| Rough-in | 9/17/2018 | 9/18/2018 | 9/18/2018 11:15:12 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ashley Stegemann- fireplace R/I ok
|
MEC18-04367
| Pressure Test | 9/11/2018 | 9/18/2018 | 9/18/2018 10:14:19 AM | A | PASS |
|
|
installer Al ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt - 20lb gas pressure test ok
|
MEC18-03260
| Final | 9/11/2018 | 9/18/2018 | 9/18/2018 9:48:12 AM | A | FAIL |
|
|
Please call Rachel prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- need to install co detectors in home- need to seal line set penetration through vent- need to seal vent at condensate penetration and place a 90 elbow turned down on condensate line
|
MEC18-04428
| Rough-in | 9/17/2018 | 9/18/2018 | 9/18/2018 9:24:19 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Ashley Stegemann- fireplace R/I ok
|
MEC18-02147
| Final | 9/14/2018 | 9/18/2018 | 9/18/2018 8:50:07 AM | A | PASS |
|
|
Call jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- final ok
|
MEC18-02145
| Final | 9/14/2018 | 9/18/2018 | 9/18/2018 8:49:52 AM | A | PASS |
|
|
Call Jason wtih any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- final ok
|
MEC17-03119
| Mec-Aging Inspection | 9/18/2018 | 9/18/2018 | 9/18/2018 8:06:11 AM | | FAIL |
|
|
need to call this permit in for a final inspection
|
MEC17-04511
| Mec-Aging Inspection | 9/18/2018 | 9/18/2018 | 9/18/2018 8:04:49 AM | | FAIL |
|
|
- still no plumbing permit for water heater
|
MEC17-04486
| Mec-Aging Inspection | 9/18/2018 | 9/18/2018 | 9/18/2018 8:02:33 AM | | CANC |
|
|
|
MEC18-02476
| Final | 9/17/2018 | 9/18/2018 | 9/18/2018 8:01:21 AM | A | CANC |
|
|
105,106,205,206,305,306 Phone #: ###-#### Inspection requested via web by Gary Reeves - rescheduled for PM
|