Inspections for the day of: Tuesday, September 18, 2018.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Reynolds
TitleMEC INSPECTOR
Phone #208-803-2395
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-04193 Final9/18/20189/18/20189/18/2018 4:22:38 PMPFAIL
Final - call RJ 30 minutes before arrival Phone #: ###-#### Inspection requested via web by Brandon Sorensen- 20lb gas pressure test ok- wet switch ok- co detectors ok- lineset penetration ok- electrical conduit for A/C ok-
- need to add other to permit for duct work in addition
MEC18-04367 Final9/18/20189/18/20189/18/2018 3:42:01 PMPPASS
INSTALLER AL ###-#### Inspection requested via web by Aaron Alandt- furnace ac coil co ok
MEC18-04233 Final9/17/20189/18/20189/18/2018 2:45:02 PMPPASS
Please call journeyman Bob Herndon ###-#### when in route-- unit will be under test Phone #: ###-#### Inspection requested via web by Justin Osterhout- furnace ac coil co ok
MEC18-04233 Pressure Test9/17/20189/18/20189/18/2018 2:44:42 PMPPASS
Please call journeyman Bob Herndon ###-#### when in route-- unit will be under test Phone #: ###-#### Inspection requested via web by Justin Osterhout- 5lb flue pressure test ok
MEC18-02476 Final9/18/20189/18/20189/18/2018 2:43:52 PMPFAIL
105,106,205,206,305,306 Phone #: ###-#### Inspection requested via web by Gary Reeves- all duct blasts ok- 106 has a hole in the return duct work that needs sealed- back draft damper outside is broken- 205- lineset insulation needs fixed and a transfer grille is missing- 206 lineset insulation needs fixed- 305 lineset insulation needs fixed-
MEC18-04522 Rough-in9/18/20189/18/20189/18/2018 1:56:03 PMPFAIL
Shaun: ###-#### Phone #: ###-#### Inspection requested via web by Frank Marturello
-duct seal on return 1st floor needs sealed on vertical seams- one flex run upstairs in bonus room is pinched between framing
MEC18-04522 Pressure Test9/18/20189/18/20189/18/2018 1:54:53 PMPPASS
Shaun: ###-#### Phone #: ###-#### Inspection requested via web by Frank Marturello
-20lb gas pressure test ok- 5lb flue pressure test ok
MEC18-01752 Final9/18/20189/18/20189/18/2018 1:54:53 PMPPASS
Field super: Daryl Thomas Phone #: ###-#### Inspection requested via web by Lisa Whitney
- final ok
MEC18-04482 Rough-in9/17/20189/18/20189/18/2018 12:01:25 PMAFAIL
Anytime! Inspection requested via web by Floyd Floyd Peek- pressure test fail- water heater b vent needs 1" clearances- equipment was not set at R/I need to check at final
MEC18-04482 Pressure Test9/17/20189/18/20189/18/2018 11:59:07 AMAFAIL
Anytime! Inspection requested via web by Floyd Floyd Peek- no pressure on the gas line and the gauge was stuck on 30lb
MEC18-04347 Rough-in9/17/20189/18/20189/18/2018 11:58:03 AMAFAIL
Phone #: ###-#### Inspection requested via web by Gary Reeves- pressure test not ready- supply trunk needs sealed at furnace- supply trunk upstairs needs sealed- seal all exhaust fans- water heater b vent upstairs needs 1" clearances on the roof
MEC18-04347 Pressure Test9/17/20189/18/20189/18/2018 11:56:41 AMANR
Phone #: ###-#### Inspection requested via web by Gary Reeves- not ready
MEC18-04430 Rough-in9/17/20189/18/20189/18/2018 11:15:12 AMAPASS
Phone #: ###-#### Inspection requested via web by Ashley Stegemann- fireplace R/I ok
MEC18-04367 Pressure Test9/11/20189/18/20189/18/2018 10:14:19 AMAPASS
installer Al ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt
- 20lb gas pressure test ok
MEC18-03260 Final9/11/20189/18/20189/18/2018 9:48:12 AMAFAIL
Please call Rachel prior to inspection. ###-#### Phone #: ###-#### Inspection requested via web by Mary LaFayette- need to install co detectors in home- need to seal line set penetration through vent- need to seal vent at condensate penetration and place a 90 elbow turned down on condensate line
MEC18-04428 Rough-in9/17/20189/18/20189/18/2018 9:24:19 AMAPASS
Phone #: ###-#### Inspection requested via web by Ashley Stegemann- fireplace R/I ok
MEC18-02147 Final9/14/20189/18/20189/18/2018 8:50:07 AMAPASS
Call jason with any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- final ok
MEC18-02145 Final9/14/20189/18/20189/18/2018 8:49:52 AMAPASS
Call Jason wtih any issues @ 412.6696 Phone #: ###-#### Inspection requested via web by Dawn Kalsbeek- final ok
MEC17-03119 Mec-Aging Inspection9/18/20189/18/20189/18/2018 8:06:11 AM FAIL
need to call this permit in for a final inspection
MEC17-04511 Mec-Aging Inspection9/18/20189/18/20189/18/2018 8:04:49 AM FAIL
- still no plumbing permit for water heater
MEC17-04486 Mec-Aging Inspection9/18/20189/18/20189/18/2018 8:02:33 AM CANC
MEC18-02476 Final9/17/20189/18/20189/18/2018 8:01:21 AMACANC
105,106,205,206,305,306 Phone #: ###-#### Inspection requested via web by Gary Reeves
- rescheduled for PM