ELE03-00279
| ELE-Aging Inspection | 9/19/2003 | 9/19/2003 | 9/19/2003 12:00:00 AM | | PASS |
|
|
lea elect 9/24/2003 7:43:24 AM
|
ELE02-03343
| Electrical Rough-In | 9/16/2003 | 9/19/2003 | 9/19/2003 12:00:00 AM | A | CANC |
|
|
GARY; Phone #: ###-#### Internet Inspection Request from: Marc Lileks wrong type insp 9/19/2003 10:39:50 AM
|
ELE03-02359
| Final | 9/17/2003 | 9/19/2003 | 9/19/2003 12:00:00 AM | A | NH |
|
|
dennis; Phone #: ###-#### Internet Inspection Request from: Marc Lileks n/h per432 9/19/2003 10:45:29 AM
|
ELE03-02923
| Temporary Service | 9/18/2003 | 9/19/2003 | 9/19/2003 12:00:00 AM | A | PASS |
|
|
###-#### kevin t/s u/g n ok per 432 9/19/2003 10:43:05 AM
|
ELE03-02836
| Permanent Service | 9/18/2003 | 9/19/2003 | 9/19/2003 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 9/18/2003 at 8:56:12 AM. Contact: ###-####.
p/s u/g rec ok survey nec300.5(d)4. 9/19/2003 10:45:00 AM
|
ELE03-00438
| Final | 9/18/2003 | 9/19/2003 | 9/19/2003 12:00:00 AM | A | NH |
|
|
GUY; Phone #: ###-#### Internet Inspection Request from: Annette Moore n/h per432 9/19/2003 10:45:59 AM
|
ELE03-02656
| Electrical Rough-In | 9/18/2003 | 9/19/2003 | 9/19/2003 12:00:00 AM | P | PART |
|
|
scott; Phone #: ###-#### Internet Inspection Request from: Barbara Moore note: the home owner said that with your phone conversation, all he needed was to have the trench inspected, without the conduit in it. the trench was not ready. i told him to go ahead put conduit in the ground, and leave eight potholes open. one on each end, and six in the middle. per 432 9/19/2003 4:21:26 PM
|
ELE03-01493
| Final | 9/19/2003 | 9/19/2003 | 9/19/2003 12:00:00 AM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 9/19/2003 at 7:24:11 AM. Contact: ###-####. no record of concrete encasement insp for ufer, upstairs closet not finished per 432 9/19/2003 4:29:01 PM
|
ELE03-02946
| Rough-In Permanent Service | 9/19/2003 | 9/19/2003 | 9/19/2003 12:00:00 AM | P | PASS |
|
|
dennis; Phone #: ###-#### Internet Inspection Request from: Marc Lileks roughin survey, 334.30 secure nm cable.
p/s u/g new ok per 432 9/19/2003 4:31:46 PM
|
ELE03-02332
| Final | 9/19/2003 | 9/19/2003 | 9/19/2003 12:00:00 AM | P | FAIL |
|
|
ALAN; Phone #: ###-#### Internet Inspection Request from: Marc Lileks fail 300.15, 110.3 (b) cabinet and lights per 432 9/19/2003 4:23:40 PM
|
ELE03-02359
| Final | 9/19/2003 | 9/19/2003 | 9/19/2003 12:00:00 AM | P | PASS |
|
|
DALE OR DOREEN; Phone #: ###-#### Internet Inspection Request from: Marc Lileks
final ok 432 9/19/2003 4:32:48 PM
|
ELE03-02897
| Permanent Service | 9/19/2003 | 9/19/2003 | 9/19/2003 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 9/19/2003 at 10:32:36 AM. Contact: ###-####.
p/s u/g rec. ok 9/19/2003 4:25:22 PM
|