ELE05-02060
| ELE-Aging Inspection | 9/19/2005 | 9/19/2005 | 9/20/2005 2:29:57 PM | | NR |
|
|
suc
|
ELE05-03403
| Permanent Service | 9/19/2005 | 9/19/2005 | 9/19/2005 4:08:30 PM | P | FAIL |
|
|
meter base/ main disconnect only due to damage from tree falling on IPCO triplex and destroying original meter/main.; Phone #: ###-#### Internet Inspection Request from: Rich Rice broken ground clamp in basement inproper and loose grounding clamps cover won't open 90deg. mast to support only service conductors mast not supported within 30 in. of weatherhead ground rod is over 1 ft above ground.
|
ELE05-03048
| Final | 9/19/2005 | 9/19/2005 | 9/19/2005 3:56:38 PM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 9/19/2005 at 9:43:44 AM. Contact: ###-####.
|
ELE05-03212
| Final | 9/19/2005 | 9/19/2005 | 9/19/2005 3:56:16 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: dennis mcneely signed card
|
ELE04-03978
| Final | 9/19/2005 | 9/19/2005 | 9/19/2005 3:55:47 PM | P | PASS |
|
|
corrections made and ready for reinspect. door open in front thanks pat; Phone #: ###-#### Internet Inspection Request from: joe wheeler no card
|
ELE05-01974
| Final | 9/19/2005 | 9/19/2005 | 9/19/2005 3:54:56 PM | P | PART |
|
|
Final on water features only; Phone #: ###-#### Internet Inspection Request from: Dana Moyer
|
ELE05-03217
| Final | 9/19/2005 | 9/19/2005 | 9/19/2005 1:08:26 PM | P | PASS |
|
|
tom; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
ELE05-03395
| Electrical Rough-In | 9/16/2005 | 9/19/2005 | 9/19/2005 12:56:08 PM | P | PART |
|
|
doug ###-#### back half of ceiling ok
|
ELE05-03401
| Temporary Service | 9/18/2005 | 9/19/2005 | 9/19/2005 10:05:02 AM | A | PASS |
|
|
Their are two power poles at this location, I have pulled a seperate permit for the other pole ; Phone #: ###-#### Internet Inspection Request from: steve sellers T/S U/G Ok
|
ELE05-03402
| Temporary Service | 9/18/2005 | 9/19/2005 | 9/19/2005 10:04:36 AM | A | PASS |
|
|
Their are two power poles at this location, I have pulled a seperate permit for the other pole ; Phone #: ###-#### Internet Inspection Request from: steve sellers T/S U/G Ok
|
ELE05-02010
| Rough-In Permanent Service | 9/16/2005 | 9/19/2005 | 9/19/2005 9:25:06 AM | A | FAIL |
|
|
james; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa 230.2 only one service 230.72 grouping of disconnects. 110.3 install factory MBJ GEC to connect to neutral
|
ELE05-03394
| Temporary Service | 9/16/2005 | 9/19/2005 | 9/19/2005 9:23:05 AM | A | FAIL |
|
|
###-#### bob connector on GEC Connect GEC to neutral
|
ELE05-02110
| ELE-Aging Inspection | 9/19/2005 | 9/19/2005 | 9/19/2005 7:50:44 AM | | NR |
|
|
suc
|
ELE04-04022
| ELE-Aging Inspection | 9/19/2005 | 9/19/2005 | 9/19/2005 7:49:04 AM | | NR |
|
|
suc
|