MEC18-04343
| Pressure Test | 9/19/2018 | 9/19/2018 | 9/19/2018 4:04:15 PM | P | PASS |
|
|
Pvc flue Phone #: ###-#### Inspection requested via web by Jon VanderStelt- 5lb flue test pass x 2
|
MEC18-02241
| Final | 9/19/2018 | 9/19/2018 | 9/19/2018 3:39:20 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Benny Arreola-need to firecaulk all penetrations in garage- single wall pipe needs 6" clearance to arma flex and flue needs grade running up hill- need sediment traps on gas line between shut off valves on gas to furnace and water heater- need to support secondary drain off coil- need to seal exterior gasline at meter, seal lineset and condensate drain exterior of building and install 3/4" pvc 90 degree outside to ground
|
MEC18-02377
| Final | 9/19/2018 | 9/19/2018 | 9/19/2018 3:33:31 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kim Evans- final ok
|
MEC18-02620
| Final | 9/19/2018 | 9/19/2018 | 9/19/2018 3:33:15 PM | P | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Kim Evans- need to fix tape in insulation coming off- need to support gas line to structure in garage- fire caulk all penetrations has holes and missing some- seal lineset at exterior open hole- need make up air register installed in dryer closet-
|
MEC18-04537
| Final | 9/18/2018 | 9/19/2018 | 9/19/2018 3:07:11 PM | P | PASS |
|
|
Please call homeowner will be home after 1:00 pm Phone #: ###-#### Inspection requested via web by Teresa Costello- FURNACE A/C COIL CO OK
|
MEC18-04486
| Final | 9/14/2018 | 9/19/2018 | 9/19/2018 2:10:59 PM | P | NH |
|
|
Please call John to ensure install is complete. Thank you! ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg- no access
|
MEC18-04235
| Rough-in | 9/18/2018 | 9/19/2018 | 9/19/2018 1:34:00 PM | P | PART |
|
|
Zach Phone #: ###-####- ok to cover new addition only- need man j onsite- need to run range hood duct and add to permit and pay fee- recall in when gas is under test and man j is insite
|
MEC18-04531
| Final | 9/19/2018 | 9/19/2018 | 9/19/2018 10:43:54 AM | A | PASS |
|
|
|
MEC18-04531
| Pressure Test | 9/18/2018 | 9/19/2018 | 9/19/2018 10:43:16 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by PATTY KIRK- 60lb gas pass underground-
|
MEC18-03629
| Final | 9/18/2018 | 9/19/2018 | 9/19/2018 9:19:58 AM | A | FAIL |
|
|
Final Fire Place Final Garage Code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- need to seal gas line penetration at meter location- need to hook up gas flexes to furnace and water heater and fire off- secondary drain off coil need to discharge to concrete need to add 45 degree fitting runs onto wood now- dryer penetration in laundry room needs sealed off open to wood structure- range hood needs finished and sealed- fireplace needs gas hooked up- left correction notice on side of furnace
|
MEC18-03630
| Final | 9/18/2018 | 9/19/2018 | 9/19/2018 9:16:14 AM | A | FAIL |
|
|
Garage Code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- needs gas hooked up and fired up
|
MEC18-04546
| Final | 9/19/2018 | 9/19/2018 | 9/19/2018 9:10:07 AM | P | CANC |
|
|
Please Call and make sure this time works with owner at. ###-#### name is Robert Frazier Phone #: ###-#### >> Inspection requested via web by Jose Rodriguez Inspection cancelled from web by: Jose Rodriguez
|
MEC17-03123
| Mec-Aging Inspection | 9/19/2018 | 9/19/2018 | 9/19/2018 9:08:27 AM | | CANC |
|
|
|
MEC17-05665
| Mec-Aging Inspection | 9/19/2018 | 9/19/2018 | 9/19/2018 9:07:44 AM | | CANC |
|
|
|
MEC17-03123
| DOC - Permit Expired | 9/19/2018 | 9/19/2018 | 9/19/2018 9:07:38 AM | A | PASS |
|
|
no calls
|
MEC17-03108
| Mec-Aging Inspection | 9/19/2018 | 9/19/2018 | 9/19/2018 9:06:20 AM | | CANC |
|
|
|
MEC17-03108
| DOC - Permit Expired | 9/19/2018 | 9/19/2018 | 9/19/2018 9:06:14 AM | A | PASS |
|
|
no calls
|