Inspections for the day of: Wednesday, September 19, 2018.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-04343 Pressure Test9/19/20189/19/20189/19/2018 4:04:15 PMPPASS
Pvc flue Phone #: ###-#### Inspection requested via web by Jon VanderStelt- 5lb flue test pass x 2
MEC18-02241 Final9/19/20189/19/20189/19/2018 3:39:20 PMPFAIL
Phone #: ###-#### Inspection requested via web by Benny Arreola-need to firecaulk all penetrations in garage- single wall pipe needs 6" clearance to arma flex and flue needs grade running up hill- need sediment traps on gas line between shut off valves on gas to furnace and water heater- need to support secondary drain off coil- need to seal exterior gasline at meter, seal lineset and condensate drain exterior of building and install 3/4" pvc 90 degree outside to ground
MEC18-02377 Final9/19/20189/19/20189/19/2018 3:33:31 PMPPASS
Phone #: ###-#### Inspection requested via web by Kim Evans- final ok
MEC18-02620 Final9/19/20189/19/20189/19/2018 3:33:15 PMPFAIL
Phone #: ###-#### Inspection requested via web by Kim Evans- need to fix tape in insulation coming off- need to support gas line to structure in garage- fire caulk all penetrations has holes and missing some- seal lineset at exterior open hole- need make up air register installed in dryer closet-
MEC18-04537 Final9/18/20189/19/20189/19/2018 3:07:11 PMPPASS
Please call homeowner will be home after 1:00 pm Phone #: ###-#### Inspection requested via web by Teresa Costello- FURNACE A/C COIL CO OK
MEC18-04486 Final9/14/20189/19/20189/19/2018 2:10:59 PMPNH
Please call John to ensure install is complete. Thank you! ###-#### Phone #: ###-#### Inspection requested via web by Rick Borg- no access
MEC18-04235 Rough-in9/18/20189/19/20189/19/2018 1:34:00 PMPPART
Zach Phone #: ###-####- ok to cover new addition only- need man j onsite- need to run range hood duct and add to permit and pay fee- recall in when gas is under test and man j is insite
MEC18-04531 Final9/19/20189/19/20189/19/2018 10:43:54 AMAPASS
MEC18-04531 Pressure Test9/18/20189/19/20189/19/2018 10:43:16 AMAPASS
Phone #: ###-#### Inspection requested via web by PATTY KIRK- 60lb gas pass underground-
MEC18-03629 Final9/18/20189/19/20189/19/2018 9:19:58 AMAFAIL
Final
Fire Place Final
Garage Code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- need to seal gas line penetration at meter location- need to hook up gas flexes to furnace and water heater and fire off- secondary drain off coil need to discharge to concrete need to add 45 degree fitting runs onto wood now- dryer penetration in laundry room needs sealed off open to wood structure- range hood needs finished and sealed- fireplace needs gas hooked up- left correction notice on side of furnace
MEC18-03630 Final9/18/20189/19/20189/19/2018 9:16:14 AMAFAIL
Garage Code 2468 Phone #: ###-#### Inspection requested via web by Randy Hart- needs gas hooked up and fired up
MEC18-04546 Final9/19/20189/19/20189/19/2018 9:10:07 AMPCANC
Please Call and make sure this time works with owner at. ###-#### name is Robert Frazier Phone #: ###-#### >> Inspection requested via web by Jose Rodriguez Inspection cancelled from web by: Jose Rodriguez
MEC17-03123 Mec-Aging Inspection9/19/20189/19/20189/19/2018 9:08:27 AM CANC
MEC17-05665 Mec-Aging Inspection9/19/20189/19/20189/19/2018 9:07:44 AM CANC
MEC17-03123 DOC - Permit Expired9/19/20189/19/20189/19/2018 9:07:38 AMAPASS
no calls
MEC17-03108 Mec-Aging Inspection9/19/20189/19/20189/19/2018 9:06:20 AM CANC
MEC17-03108 DOC - Permit Expired9/19/20189/19/20189/19/2018 9:06:14 AMAPASS
no calls