Inspections for the day of: Friday, September 2, 2011.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE11-02036 Temporary Service9/2/20119/2/20119/2/2011 2:57:01 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Rowdy Monroe t/s u/g n ok
ELE11-02037 Temporary Service9/2/20119/2/20119/2/2011 2:56:28 PMPPASS
Phone #: ###-#### >> Inspection requested via web by Rowdy Monroe t/s u/g n ok
ELE11-01463 Final9/2/20119/2/20119/2/2011 2:51:10 PMPPASS
We have completed the installation to the Heat Pump. Our Electrician that performed the installation is Jose (Can Speak Spanish if needed) @ ###-####. Thank you. The Tenant, Mary Rogue can be reached at ###-#### Phone #: ###-#### >> Inspection requested via web by Clint Tate ok final
ELE11-01929 Electrical Rough-In9/2/20119/2/20119/2/2011 2:33:09 PMPPASS
Jared-Underground upher inspection Phone #: ###-#### ok cover concrete encased electrode
ELE10-01991 Electrical Rough-In9/2/20119/2/20119/2/2011 1:26:44 PMPPASS
Valerie Phone #: ###-#### corrections made, ri ok
ELE08-02423 Electrical Rough-In9/2/20119/2/20119/2/2011 12:36:44 PMPPASS
Underground---Jason Phone #: ###-#### ok cover u/g south of pool road, west side driveway, both sides
ELE11-01922 Final9/1/20119/2/20119/2/2011 11:37:38 AMAPASS
see notes 09-01-11 PM request for info ok final
ELE11-01867 Rough-In Permanent Service9/1/20119/2/20119/2/2011 11:36:55 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by Therrin Robertson called, left correction notice, NEC 334.23 shall protect cables within 6' of attic accesses, 362.30 shall secure ent within 3' of termination, 312.5 shall provide abrasion protection for cables in lv cabinet, 300.4(A) edge of hole shall be 1 14" from edge of framing member, or provide nailplate, BCC approved set of plans shall be on job
ELE11-01681 Final9/1/20119/2/20119/2/2011 9:41:53 AMAPASS
Phone #: ###-#### >> Inspection requested via web by mike brown ok final, signed card
ELE11-01988 Permanent Service9/1/20119/2/20119/2/2011 9:04:55 AMAPASS
code is 4907, house is vacant. service is on side of house in the backyard Phone #: ###-#### >> Inspection requested via web by Brad Girard corrections made, p/s o/h rec ok
ELE11-02026 Rough-In Permanent Service9/1/20119/2/20119/2/2011 8:43:11 AMAPASS
Jason will be the contact for today Phone #: ###-#### >> Inspection requested via web by Rick Beckman ri ok, p/s o/h n ok, 2 meters req'd
ELE11-01448 Final9/2/20119/2/20119/2/2011 7:52:02 AMAPASS
Call Dene with access code
Thank you Phone #: ###-#### >> Inspection requested via web by kim grundhauser ok final
ELE11-00463 Final9/2/20119/2/20119/2/2011 7:24:14 AMAPASS
ok final
ELE11-00477 ELE-Aging Inspection9/2/20119/2/20119/2/2011 7:23:15 AM DONE
still under construction
ELE10-02823 ELE-Aging Inspection9/2/20119/2/20119/2/2011 7:22:11 AM DONE
still under construction