PLM14-01945
| PLM-Aging Inspection | 9/2/2015 | 9/2/2015 | 9/3/2015 3:30:17 PM | | PASS |
|
|
work completed
|
PLM14-00990
| PLM-Aging Inspection | 9/2/2015 | 9/2/2015 | 9/3/2015 8:24:49 AM | | PASS |
|
|
all med gas work was done under plm14--00573 and bld-14-00038
|
PLM15-02294
| Final | 9/2/2015 | 9/2/2015 | 9/2/2015 4:14:08 PM | P | FAIL |
|
|
JOB # 18065. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes >i. need a 1" air gap at prepiped softener drain. >ii.main upper bath flooded from wc leak, I turned water off at wc.
|
PLM15-01849
| Plumbing Rough-in | 9/2/2015 | 9/2/2015 | 9/2/2015 3:45:33 PM | P | FAIL |
|
|
Ready anytime Thanks Phone #: ###-#### Inspection requested via web by Erin Whiting >DWV test fail-leak at wb trap unit 102
|
PLM15-02814
| Plumbing Rough-in | 9/1/2015 | 9/2/2015 | 9/2/2015 3:24:45 PM | P | FAIL |
|
|
PAUL THOMPSON, JOB SUPERVISOR. Phone #: ###-#### Inspection requested via web by Chris Field 1>DWV test failed, below 5psi 2>missing nail plates throughout 3>need support at base of 3" stack 4>bow in hor vent from tub to lavs upstairs 5>rubber fernco in crawl needs to be a shielded coupling 6>water service connection does not appear to be an approved fitting for p.e. pipe. 7>strap water service up from resting on concrete edge.
|
PLM15-02959
| Plumbing Rough-in | 9/2/2015 | 9/2/2015 | 9/2/2015 2:35:19 PM | P | PASS |
|
|
CHARILE IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER
|
PLM15-02365
| Groundwork | 9/2/2015 | 9/2/2015 | 9/2/2015 2:12:09 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brent Lacy >sw bathroom ok >se bathroom ok and sink ok
|
PLM15-00697
| DOC - Permit Finaled | 9/2/2015 | 9/2/2015 | 9/2/2015 11:58:38 AM | P | PASS |
|
|
|
PLM15-00697
| PLM-Aging Inspection | 9/2/2015 | 9/2/2015 | 9/2/2015 11:58:18 AM | | PASS |
|
|
finaled by BV but never doc finaled.
|
PLM15-02220
| Final | 9/2/2015 | 9/2/2015 | 9/2/2015 11:52:50 AM | P | PASS |
|
|
JOB # 13189. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|
PLM15-01371
| Plumbing Rough-in | 9/1/2015 | 9/2/2015 | 9/2/2015 11:09:02 AM | A | PASS |
|
|
DAVID IS THE JOB CONTACT ###-#### Phone #: ###-#### Inspection requested via web by BECCA DUMMER > RD on sw side showroom ok, df ok, sink ok to cover. >add hangers on 6" o/h for rd's to support every 4' not 6'.
|
PLM15-01169
| PLM-Aging Inspection | 9/2/2015 | 9/2/2015 | 9/2/2015 10:38:38 AM | | CANC |
|
|
wip
|
PLM15-02984
| Water and/or Sewer | 9/1/2015 | 9/2/2015 | 9/2/2015 10:09:51 AM | A | PART |
|
|
OWNER, OLGA GOTRA, ###-####. NEW WATER MAIN. Phone #: ###-#### Inspection requested via web by Chris Field > ok to bury, sprinkler backflow needs certified for final.
|
PLM15-02990
| Water and/or Sewer | 9/1/2015 | 9/2/2015 | 9/2/2015 9:40:06 AM | A | PART |
|
|
new address for this is 1125 N Five Mile Phone #: ###-#### Inspection requested via web by Darren Wood >water ok >sewer ok to bury, but not complete, remainder needs to be inspected when ready.
|
PLM15-01444
| Final | 9/1/2015 | 9/2/2015 | 9/2/2015 9:17:51 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Aarin Van Curen >drain on garbage disposal back graded >need water softener permitted before final by installing contractor.
|
PLM15-02911
| Water Heater Final | 8/27/2015 | 9/2/2015 | 9/2/2015 8:45:26 AM | A | PASS |
|
|
water heater final. homeowner request am inspection. Please call en route. George Druzisky ###-#### Phone #: ###-#### Inspection requested via web by TERRY SIDWELL
|
PLM15-02134
| Final | 9/1/2015 | 9/2/2015 | 9/2/2015 8:23:17 AM | A | PASS |
|
|
JOB # 18047. Phone #: ###-#### Inspection requested via web by Ann Marie Reyes
|