Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-00671 Electrical Rough-In9/20/20069/20/20069/20/2006 4:15:02 PMPPASS
tye Note: underground; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles sit lighting u/g ok to cover
ELE06-03469 Electrical Rough-In9/18/20069/20/20069/20/2006 4:01:57 PMPFAIL
Work performed by Steve Johnson.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz called, left corr notice, nec 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 210.52(A)(1) recpts shall be installed so that no point along wall space is over 6' from an outlet, 314.20 boxes in combustible walls shall be flush with the finished surface, BCC all make-up shall be done, and boxes added
ELE06-03441 Electrical Rough-In9/20/20069/20/20069/20/2006 3:22:09 PMPPASS
TOBY WALLS; Phone #: ###-#### Internet Inspection Request from: Sean DeLacy walls only ok to cover
ELE06-02254 Electrical Rough-In9/20/20069/20/20069/20/2006 2:46:14 PMPPART
Scheduled by a contractor via Hello! on 9/20/2006 at 7:11:46 AM. Contact: ###-####. u/g so side new bldg ok to cover, will be between bldgs
ELE06-01438 Rough-In Permanent Service9/20/20069/20/20069/20/2006 1:43:00 PMPPASS
daniel - call prior for access (outside insp only); Phone #: ###-#### Internet Inspection Request from: Barbara Buckley p/s o/h n ok
ELE06-03261 Rough-In Permanent Service9/20/20069/20/20069/20/2006 1:06:58 PMPPASS
brian - ceiling & service; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley hard lid clgs ok to cover, p/s exst meter pak, 2 meters, n ok
ELE06-02059 Permanent Service9/20/20069/20/20069/20/2006 12:30:53 PMPPASS
This was called in incorrect before -should have been a RI/PERMANENT SERVICE NOT A PERMANET SERVICE SO IT IS NOW READY FOR A PERMANENT SERVICE PER JIM S. p/s o/h rec ok ok'd by 324 6-15-06, called ipco to confirm power apparently is on
ELE06-02621 Final9/20/20069/20/20069/20/2006 10:42:17 AMAPASS
If no answer at door call jason starner at 484 0180 he is the general contractor that said he was going to be there to day .Thank you and have a great day.; Phone #: ###-#### Internet Inspection Request from: steven sewell called contr, survey, nec 210.52(C)(1) recpt shall be installed in counter space 12" or wider, 406.5 recpt faceplates shall seat against mounting surface, Bcc range hood shall be listed and labelled, ok to final
ELE06-02588 Final9/19/20069/20/20069/20/2006 9:55:04 AMAPASS
Scheduled by a contractor via Hello! on 9/19/2006 at 1:25:30 PM. Contact: ###-####. ok to final
ELE06-02613 Final9/19/20069/20/20069/20/2006 9:21:36 AMAPART
any questions please call James Lingelbaugh; Phone #: ###-#### Internet Inspection Request from: Jeff Radford down stairs ok except floor boxes, no mezzanine access- need to check, need to check elev, told needed showroom recpts
ELE06-00113 Final9/19/20069/20/20069/20/2006 8:54:37 AMAPART
gregg - partial final on 9th floor; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley 9th fl recpts and clg except anop ok
ELE06-03478 Final9/20/20069/20/20069/20/2006 6:27:52 AMAPASS
ok to final