ELE06-00711
| ELE-Aging Inspection | 9/20/2007 | 9/20/2007 | 9/20/2007 4:05:21 PM | A | CANC |
|
|
|
ELE06-00711
| Electrical Rough-In | 9/19/2007 | 9/20/2007 | 9/20/2007 4:04:57 PM | P | CANC |
|
|
Scheduled by a contractor via Hello! on 9/19/2007 at 7:13:34 AM. Contact: ###-####. see added AM for 09-21-07, contractor not at job site quit at 4:00 PM called no response left message
|
ELE07-03071
| Permanent Service | 9/20/2007 | 9/20/2007 | 9/20/2007 3:53:11 PM | P | PART |
|
|
Please inspect main service outside and sub-panel inside. Water pipe is bonded to at the sub-panel (could not locate water main within 5'' of entrance). Todd Hall spoke with Jim Schmear on 9-19 regarding approval to bond to water pipe inside of residence. Customer is building a soffit for protection of SER and NMBs ran along ceiling in bedroom where sub-panel is located. 3-wire range and dryer are extended to main panel outside. Home owner moved cable TV aside on soffit above main service. Home owner needs IDPCO reconnection in afternoon. Call Todd Hall if any questions. ###-#### Phone #: ###-#### Internet Inspection Request from: Tracy Robertson see added t/s, corr. posted on what is required for p/s Bob R has copy of corr.
|
ELE07-03071
| Temporary Service | 9/20/2007 | 9/20/2007 | 9/20/2007 3:49:37 PM | P | PART |
|
|
Please inspect main service outside and sub-panel inside. Water pipe is bonded to at the sub-panel (could not locate water main within 5'' of entrance). Todd Hall spoke with Jim Schmear on 9-19 regarding approval to bond to water pipe inside of residence. Customer is building a soffit for protection of SER and NMBs ran along ceiling in bedroom where sub-panel is located. 3-wire range and dryer are extended to main panel outside. Home owner moved cable TV aside on soffit above main service. Home owner needs IDPCO reconnection in afternoon. Call Todd Hall if any questions. ###-#### Phone #: ###-#### Internet Inspection Request from: Tracy Robertson p/s is on a temp basis for now t/s o/h rec ok
|
ELE07-02706
| Final | 9/20/2007 | 9/20/2007 | 9/20/2007 2:17:47 PM | P | PASS |
|
|
###-#### Internet Inspection Request from: Todd Holbrook ok no card
|
ELE07-03221
| Electrical Rough-In | 9/20/2007 | 9/20/2007 | 9/20/2007 1:45:59 PM | P | PART |
|
|
mike Note;t rench Phone #: ###-#### u/g for parking lot lights feed from red barn ok note this is behind business N side of fairview, west of cloverdale
|
ELE07-02083
| Final | 9/20/2007 | 9/20/2007 | 9/20/2007 1:14:10 PM | P | FAIL |
|
|
dan Phone #: ###-#### 110.3(B) shall follow manufacture's instructions needs 16'x20' access and 20 amp configuration recept called corr. posted
|
ELE07-03143
| Permanent Service | 9/20/2007 | 9/20/2007 | 9/20/2007 12:30:38 PM | P | CANC |
|
|
Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer called no access wet concrete
|
ELE07-03143
| Final | 9/19/2007 | 9/20/2007 | 9/20/2007 10:32:09 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer called job not ready for final contr will reschedule for p/s ?
|
ELE07-01636
| Permanent Service | 9/19/2007 | 9/20/2007 | 9/20/2007 10:14:00 AM | A | CANC |
|
|
please contact Darin Stubbs at ###-#### to meet for access. Phone #: ###-#### Internet Inspection Request from: BRENDA HURST owner called said no t to come out he needs to talk to ele contr I
|
ELE07-03262
| Electrical Rough-In | 9/19/2007 | 9/20/2007 | 9/20/2007 10:01:19 AM | A | NH |
|
|
james Phone #: ###-#### called
|
ELE07-03263
| Rough-In Permanent Service | 9/19/2007 | 9/20/2007 | 9/20/2007 9:21:37 AM | A | FAIL |
|
|
Phone #: ###-#### Internet Inspection Request from: Joe Thomas corr called300.4 needs nail plates everywhere, 314.17(A&C) replace outside recept boxes with broken out factory clamps, 334.23 protect cables within 6ft of attic accesses, BCC complete all makeup and grd boxes (outside lights and recepts)
|
ELE07-03145
| Electrical Rough-In | 9/19/2007 | 9/20/2007 | 9/20/2007 8:17:50 AM | A | PASS |
|
|
ed Note: please call 1/2 hr prior to inspection Phone #: ###-#### floor heat ok
|