Inspections for the day of: Thursday, September 20, 2007.
Number of inspections: 13
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-00711 ELE-Aging Inspection9/20/20079/20/20079/20/2007 4:05:21 PMACANC
ELE06-00711 Electrical Rough-In9/19/20079/20/20079/20/2007 4:04:57 PMPCANC
Scheduled by a contractor via Hello! on 9/19/2007 at 7:13:34 AM. Contact: ###-####. see added AM for 09-21-07, contractor not at job site quit at 4:00 PM called no response left message
ELE07-03071 Permanent Service9/20/20079/20/20079/20/2007 3:53:11 PMPPART
Please inspect main service outside and sub-panel inside. Water pipe is bonded to at the sub-panel (could not locate water main within 5'' of entrance). Todd Hall spoke with Jim Schmear on 9-19 regarding approval to bond to water pipe inside of residence. Customer is building a soffit for protection of SER and NMBs ran along ceiling in bedroom where sub-panel is located. 3-wire range and dryer are extended to main panel outside. Home owner moved cable TV aside on soffit above main service. Home owner needs IDPCO reconnection in afternoon. Call Todd Hall if any questions. ###-#### Phone #: ###-#### Internet Inspection Request from: Tracy Robertson see added t/s, corr. posted on what is required for p/s Bob R has copy of corr.
ELE07-03071 Temporary Service9/20/20079/20/20079/20/2007 3:49:37 PMPPART
Please inspect main service outside and sub-panel inside. Water pipe is bonded to at the sub-panel (could not locate water main within 5'' of entrance). Todd Hall spoke with Jim Schmear on 9-19 regarding approval to bond to water pipe inside of residence. Customer is building a soffit for protection of SER and NMBs ran along ceiling in bedroom where sub-panel is located. 3-wire range and dryer are extended to main panel outside. Home owner moved cable TV aside on soffit above main service. Home owner needs IDPCO reconnection in afternoon. Call Todd Hall if any questions. ###-#### Phone #: ###-#### Internet Inspection Request from: Tracy Robertson p/s is on a temp basis for now t/s o/h rec ok
ELE07-02706 Final9/20/20079/20/20079/20/2007 2:17:47 PMPPASS
###-#### Internet Inspection Request from: Todd Holbrook ok no card
ELE07-03221 Electrical Rough-In9/20/20079/20/20079/20/2007 1:45:59 PMPPART
mike Note;t rench Phone #: ###-####
u/g for parking lot lights feed from red barn ok note this is behind business N side of fairview, west of cloverdale
ELE07-02083 Final9/20/20079/20/20079/20/2007 1:14:10 PMPFAIL
dan Phone #: ###-#### 110.3(B) shall follow manufacture's instructions needs 16'x20' access and 20 amp configuration recept called corr. posted
ELE07-03143 Permanent Service9/20/20079/20/20079/20/2007 12:30:38 PMPCANC
Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer called no access wet concrete
ELE07-03143 Final9/19/20079/20/20079/20/2007 10:32:09 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Jarrod Clymer called job not ready for final contr will reschedule for p/s ?
ELE07-01636 Permanent Service9/19/20079/20/20079/20/2007 10:14:00 AMACANC
please contact Darin Stubbs at ###-#### to meet for access.
Phone #: ###-#### Internet Inspection Request from: BRENDA HURST
owner called said no t to come out he needs to talk to ele contr I
ELE07-03262 Electrical Rough-In9/19/20079/20/20079/20/2007 10:01:19 AMANH
james Phone #: ###-#### called
ELE07-03263 Rough-In Permanent Service9/19/20079/20/20079/20/2007 9:21:37 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Joe Thomas corr called300.4 needs nail plates everywhere, 314.17(A&C) replace outside recept boxes with broken out factory clamps, 334.23 protect cables within 6ft of attic accesses, BCC complete all makeup and grd boxes (outside lights and recepts)
ELE07-03145 Electrical Rough-In9/19/20079/20/20079/20/2007 8:17:50 AMAPASS
ed Note: please call 1/2 hr prior to inspection Phone #: ###-#### floor heat ok