Inspections for the day of: Thursday, September 20, 2012.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE12-02227 Electrical Rough-In9/20/20129/20/20129/20/2012 2:47:06 PMPPASS
underground conduit in kitchen Phone #: ###-#### >> Inspection requested via web by Joe Thomas ok
ELE12-02229 Electrical Rough-In9/20/20129/20/20129/20/2012 2:46:22 PMPPASS
underground conduit in kitchen Phone #: ###-#### >> Inspection requested via web by Joe Thomas ok
ELE12-02228 Electrical Rough-In9/20/20129/20/20129/20/2012 2:45:39 PMPPASS
underground conduit in kitchen Phone #: ###-#### >> Inspection requested via web by Joe Thomas ok
ELE12-02074 Electrical Rough-In9/19/20129/20/20129/20/2012 2:42:29 PMPFAIL
michael Phone #: ###-#### shall provide 6" free conductor length in boxes, shall provide outlet within 6' of door entering room
ELE12-02359 Rough-In Permanent Service9/20/20129/20/20129/20/2012 1:56:36 PMPPASS
Phone #: ###-#### >> Inspection requested via web by kevin blackmon ri ok, p/s u/g n ok
ELE12-02355 Final9/20/20129/20/20129/20/2012 12:53:07 PMPPASS
vacant - key under mat Phone #: ###-#### >> Inspection requested via web by Mitch Whited ok final
ELE12-02355 Permanent Service9/20/20129/20/20129/20/2012 12:52:47 PMPPASS
vacant - key under mat Phone #: ###-#### >> Inspection requested via web by Mitch Whited p/s, exst meter pak, rec, ok
ELE12-01847 Final9/20/20129/20/20129/20/2012 12:44:18 PMPPASS
Garage entrance code 1968E Phone #: ###-#### >> Inspection requested via web by Alan Lusk ok final
ELE12-02254 Final9/20/20129/20/20129/20/2012 12:11:19 PMPPASS
call steve with any questions or concerns thanks
Phone #: ###-#### >> Inspection requested via web by Don Lustig ok final, signed card
ELE11-02855 Electrical Rough-In9/20/20129/20/20129/20/2012 11:42:43 AMPPASS
steve Phone #: ###-#### walls ok anop
ELE12-01960 Final9/19/20129/20/20129/20/2012 11:14:18 AMPCANC
Please call me at ###-#### so I can meet and let you in. Thanks Richard Phone #: ###-#### >> Inspection requested via web by Richard Corn called, will recall
ELE12-02340 Electrical Rough-In9/20/20129/20/20129/20/2012 11:06:57 AMPPASS
Key lockbox code 5343 or 5588 Phone #: ###-#### >> Inspection requested via web by David Nelson ri ok, p/s u/g rec ok
ELE12-02128 Electrical Rough-In9/19/20129/20/20129/20/2012 10:18:29 AMAPASS
call on arrival so I can let you in. Please don''t show up before 9 am. Phone #: ###-#### >> Inspection requested via web by Brian Hughes ri ok
ELE12-02347 Final9/19/20129/20/20129/20/2012 9:46:27 AMAPASS
wiring for new heat pump, any questions call Jake @ ###-#### Phone #: ###-#### >> Inspection requested via web by Andy Rose ok final
ELE12-02068 Final9/20/20129/20/20129/20/2012 9:27:19 AMACANC
Phone #: ###-#### >> Inspection requested via web by kevin blackmon called, wrong house and request, wants to call another for pm
ELE11-01514 Electrical Rough-In9/19/20129/20/20129/20/2012 9:19:36 AMANR
carl Phone #: ###-#### shall do make-up and recall
ELE12-02323 Rough-In Permanent Service9/19/20129/20/20129/20/2012 8:51:20 AMAPASS
Phone #: ###-#### >> Inspection requested via web by Joe Thomas ri ok, u/g ok, p/s u/g n ok
ELE12-02221 Final9/19/20129/20/20129/20/2012 8:12:28 AMAPASS
Contact Steve Panzella Phone #: ###-#### >> Inspection requested via web by Deb Gooden ok cover ceilings, ok final, no card
ELE12-01839 Final9/20/20129/20/20129/20/2012 7:53:13 AMAFAIL
Phone #: ###-#### >> Inspection requested via web by kevin blackmon called, left message, shall check garage rear door light, shall add receptacle at rear of dwelling per NEC 210.52(E)