ELE16-01589
| Final | 9/19/2016 | 9/20/2016 | 9/20/2016 2:33:11 PM | P | PASS |
|
|
Final on building T 3rd and 4th floor. Call Doug with questions Phone #: ###-#### Inspection requested via web by Bob Stephens final ok as per notes.
|
ELE15-00589
| Electrical Rough-In | 9/19/2016 | 9/20/2016 | 9/20/2016 1:55:28 PM | P | NR |
|
|
Verrick-pleae call with an approx meet time-20 minutes if poss Phone #: ###-####
|
ELE16-03010
| Electrical Rough-In | 9/19/2016 | 9/20/2016 | 9/20/2016 1:38:35 PM | P | PASS |
|
|
Wall inspection. Shannon is the contact his cell no. is ###-#### Phone #: ###-#### Inspection requested via web by Shawna Gates ok cover
|
ELE16-02998
| Conference | 9/20/2016 | 9/20/2016 | 9/20/2016 1:25:29 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jarad Knudson talked about outlet placement for new dining rm addition
|
ELE16-02958
| Electrical Rough-In | 9/20/2016 | 9/20/2016 | 9/20/2016 1:10:49 PM | P | PASS |
|
|
Please call 30 min ahead. Phone #: ###-#### Inspection requested via web by William Andrews ok cover
|
ELE16-01965
| Electrical Rough-In | 9/20/2016 | 9/20/2016 | 9/20/2016 12:35:01 PM | P | FAIL |
|
|
would like call ahead; Marco Phone #: ###-#### boxes need changed out due to box fill, need connectors for wires entering cans, wires need stapled every 4-1/2', boxes need made up to ensure ground wire connection
|
ELE16-03049
| Final | 9/20/2016 | 9/20/2016 | 9/20/2016 12:01:59 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Darryn Coburn final ok
|
ELE15-03443
| Final | 9/19/2016 | 9/20/2016 | 9/20/2016 9:54:08 AM | A | PASS |
|
|
Kristina Phone #: ###-#### final ok
|
ELE16-02428
| Final | 9/19/2016 | 9/20/2016 | 9/20/2016 9:33:27 AM | A | FAIL |
|
|
Ron Phone #: ###-#### 1. smoke detectors need arc fault protection. 2. garbage disposal needs pigtail no longer than 3'. 3. Outlet down low in front of kitchen sink to left of cabinets needs GFI protection, it is within 6' of sink.
|
ELE16-01878
| Final | 9/19/2016 | 9/20/2016 | 9/20/2016 8:43:56 AM | A | PASS |
|
|
access 4878 Phone #: ###-#### Inspection requested via web by David Nelson final ok
|
ELE16-03041
| Rough-In Permanent Service | 9/19/2016 | 9/20/2016 | 9/20/2016 8:29:59 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Richard Gratiot p/s u/g n ok
|
ELE16-03042
| Rough-In Permanent Service | 9/19/2016 | 9/20/2016 | 9/20/2016 8:29:35 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Richard Gratiot p/s u/g n ok
|