Inspections for the day of: Thursday, September 20, 2018.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBrian Scoles
TitleMEC INSPECTOR
Phone #914-4915
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
MEC18-03460 Rough-in9/20/20189/20/20189/20/2018 3:55:25 PMPPASS
Second layer of fire wrap and roof top inpsector. We will be there by 2:30 finishing up some other things. Phone #: ###-#### Inspection requested via web by Drew Tverdy- second layer wrap ok on grease duct and smoker- roof ok- need to roof in curbs weater tight by final- need to install plywood in attic where ladder from serving area is- talked to owner about this- need equipment set into working place by final inspection and have air balance report onsite
MEC18-02620 Conference9/20/20189/20/20189/20/2018 3:42:29 PMACANC
meet Daniel at 8 to 815 am- i schedule for wrong date
MEC18-04440 Pressure Test9/20/20189/20/20189/20/2018 3:41:15 PMACANC
meet at 830 to 9 to for gas test- wrong date i will reschedule for tomorrow morning
MEC18-04440 Final9/19/20189/20/20189/20/2018 3:31:24 PMPCANC
installer Anas ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- n o final will be given until range hood is installed and hooked up- need to support 6" exhaust in attic before cover will be given- this should have been R/I inspection
MEC18-04440 Pressure Test9/19/20189/20/20189/20/2018 3:30:05 PMPNR
installer Anas ###-#### Phone #: ###-#### Inspection requested via web by Aaron Alandt- still installing- gas wasnt under pressure- need to reschedule for tomorrow morning and i will be there between 830 and 9 am
MEC18-04505 Final9/20/20189/20/20189/20/2018 3:12:56 PMPFAIL
Would like late PM and call on way. Thank you Phone #: ###-#### Inspection requested via web by Xanti Berria- single wall wye branch on flue is rotted out- need to replace with b vent wye and maintain 6" clearance to combustibles on single wall pipe to water heater and furnace-
MEC18-02620 Final9/20/20189/20/20189/20/2018 2:42:16 PMPNR
Phone #: ###-#### Inspection requested via web by Kim Evans- have clearance issues with water heater combustion per plumbing inspector- will get with Daniel in morning at 815 to go over quick fix
MEC18-04343 Rough-in9/20/20189/20/20189/20/2018 1:55:59 PMPPASS
Phone #: ###-#### Inspection requested via web by Jon VanderStelt- R/I ok- will look at equipment and linset at final- need to add other and 1 a/c to permit
MEC18-04470 Final9/18/20189/20/20189/20/2018 10:58:14 AMAPASS
after 1030am- 208 954 3097- furnace a/c coil co ok
MEC18-04486 Final9/19/20189/20/20189/20/2018 9:45:26 AMAPASS
Please call Joan when on the way ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Rick Borg- furnace co ok
MEC18-02965 Final9/19/20189/20/20189/20/2018 9:45:10 AMPCANC
Matt Phone #: ###-####- per phone call from matt- will reschedule
MEC17-05663 Mec-Aging Inspection9/20/20189/20/20189/20/2018 8:22:58 AM FAIL
contractor needs to schedule inspection if work was done