Inspections for the day of: Thursday, September 20, 2018.
Number of inspections: 13
Percentage of inspections complete: 92 %
Percentage of inspections not complete: 8 %
Contact Information
InspectorMike Jordan
TitleBLD-COM/RES INSPECTOR
Phone #794-9473
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD17-04447 BLD-Concrete9/18/20189/19/2018 A 
Hey Mike, we are placing a slab on grade tomorrow at 4am, strata will b onsite for rebar and concrete testing. You could look at our slab prep today if you come out for the grout placement Phone #: ###-#### >> Inspection requested via web by Jim Carriveau
BLD18-02973 BLD-Final9/19/20189/20/20189/20/2018 4:40:01 PMPDONE
Phone #: ###-#### Inspection requested via web by BRS Permitting
BLD18-02973 DOC - Permit Finaled9/20/20189/20/20189/20/2018 4:39:52 PMPPASS
BLD17-01656 FIRE-Final Inspection9/20/20189/20/20189/20/2018 3:58:55 PMPPASS
Jack Phone #: ###-####. All issues have been resolved.
BLD18-01380 BLD-Framing/Rough-in9/20/20189/20/20189/20/2018 3:26:30 PMPPASS
Rick Phone #: ###-####. Air seal pak ok.
BLD18-03027 FIRE-Final Inspection9/19/20189/20/20189/20/2018 3:06:09 PMPNR
Steve Phone #: ###-####. No one site. No call back. Will need to rechedule.
BLD18-02483 BLD-Energy code compliance9/20/20189/20/20189/20/2018 2:56:13 PMPPASS
Phone #: ###-#### Inspection requested via web by Andy Thompson
BLD18-02713 FIRE-Final Inspection9/20/20189/20/20189/20/2018 2:41:04 PMPFAIL
Russ Phone #: ###-####. Provide fire extinguisher with current inspection tag. Contractor to schedule fire conferance in the am for fire sprinkler and fire alram concerns.
BLD17-01247 FIRE-Final Inspection9/20/20189/20/20189/20/2018 1:59:22 PMPFAIL
Tim Phone #: ###-####. Repair the functioning emergency lighting.
FIR18-00729 INSP-Sprinkler Rough-in9/20/20189/20/20189/20/2018 1:15:10 PMPNR
UG COVER INSP. ROY Phone #: ###-#### Inspection requested via web by Nathan Stenquist. Trench being excavated and lined with sand. Will need to recall when ready.
BLD17-03234 FIRE-Final Inspection9/19/20189/20/20189/20/2018 11:55:31 AMACANC
call for bike rack location-Chris Phone #: ###-####
BLD18-01425 BLD-Foundation9/19/20189/20/20189/20/2018 9:52:01 AMAPART
James Phone #: ###-####. Exterior perimeter footings for Area 2. Noted 4 F4B type column pad footings that require top and bottom mats of #4 rebar. Only one mat has been installed at this time. Special inspector to verify repair of these 4 F4B column pad footings prior to concrete placement.
BLD18-02483 BLD-Energy code compliance9/19/20189/20/20189/20/2018 8:50:24 AMAFAIL
Phone #: ###-#### Inspection requested via web by Andy Thompson. No vapor retarder installed. Non of the additional requirements have been met to use latex paint.