ELE17-03192
| ELE-Aging Inspection | 9/20/2019 | 9/20/2019 | 9/25/2019 7:22:03 AM | | FAIL |
|
|
no access...homeowner needs to schedule
|
ELE19-02534
| Electrical Rough-In | 9/20/2019 | 9/20/2019 | 9/20/2019 2:35:33 PM | P | PASS |
|
|
Can you come at 3:30 or after. I have a pressure test and mechanical inspection around 2:30. Phone #: ###-#### Inspection requested via web by Daniel Grover...ok to cover rough and ceiling...requiring 2nd rough inspection for make-up before any final
|
ELE17-03275
| ELE-Aging Inspection | 9/20/2019 | 9/20/2019 | 9/20/2019 1:54:06 PM | | FAIL |
|
|
contractor needs to schedule final and get access
|
ELE19-03177
| Conference | 9/20/2019 | 9/20/2019 | 9/20/2019 1:22:03 PM | P | PASS |
|
|
John Phone #: ###-####....mst bath...re-designing layout using existing circuits...adding outlets for 2nd vanity and lights...homeowner competent...pamphlet given
|
ELE19-03165
| Electrical Rough-In | 9/20/2019 | 9/20/2019 | 9/20/2019 12:16:18 PM | P | PASS |
|
|
Ceiling Inspection, Chad Vanorden is contact at ###-####. Phone #: ###-#### Inspection requested via web by Debby Pierce... grid ok to cover
|
ELE19-02997
| Final | 9/20/2019 | 9/20/2019 | 9/20/2019 12:06:24 PM | P | PASS |
|
|
Contact: Damonn Barr Phone #: ###-#### Inspection requested via web by Deb Gooden...ok to final
|
ELE19-03547
| Electrical Rough-In | 9/19/2019 | 9/20/2019 | 9/20/2019 11:20:28 AM | A | PASS |
|
|
Please call ahead Phone #: ###-#### Inspection requested via web by Kyle Dillon.. new walls for offices ok to cover ceiling grid staying as is lighting in warehouse ok no floor outlet required no conference room as per print
|
ELE19-02326
| Final | 9/20/2019 | 9/20/2019 | 9/20/2019 10:31:24 AM | P | PASS |
|
|
Requesting 10:00 am inspection. Replace 3 wall signs with new signs reading Extra Mile. Phone #: ###-#### Inspection requested via web by Ken Olsen...ok to final
|
ELE19-02326
| Electrical Rough-In | 9/13/2019 | 9/20/2019 | 9/20/2019 10:31:04 AM | A | PASS |
|
|
Requesting 10:00 am inspection. Replace 3 wall signs with new signs reading Extra Mile. Phone #: ###-#### Inspection requested via web by Ken Olsen...UL listing verified...LED... existing circuit used replacing old signage
|
ELE19-02349
| Electrical Rough-In | 9/20/2019 | 9/20/2019 | 9/20/2019 10:03:22 AM | P | PASS |
|
|
We need a uffer inspection for Bld. 3 Please. As early as possible would be great. Thank you Phone #: ###-#### Inspection requested via web by Tom Jenkins... ok to cover...uffer and conduit stubs
|
ELE19-03389
| Final | 9/19/2019 | 9/20/2019 | 9/20/2019 9:42:03 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by kendall bender...ok to final
|
ELE19-03569
| Rough-In Permanent Service | 9/20/2019 | 9/20/2019 | 9/20/2019 9:20:55 AM | A | CANC |
|
|
Phone #: ###-#### Inspection requested via web by JENNY EMEL...wrong inspection scheduled...rough in done
|
ELE19-03569
| Electrical Rough-In | 9/20/2019 | 9/20/2019 | 9/20/2019 9:20:01 AM | P | PASS |
|
|
This is the correct inspection for this morning. My apologies
Have a nice day! Phone #: ###-#### Inspection requested via web by JENNY EMEL... ok to cover dropped ceiling and bakery service back wall...discussed mini cans being cut in after sheetrock installed in drop ceiling...junctions for mini cans are non IC rated...no insulation can be on top of drop ceiling
|
ELE19-03564
| Electrical Rough-In | 9/19/2019 | 9/20/2019 | 9/20/2019 8:32:44 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Joseph Yergensen... building permit required before any work can start...approval needed by city of Boise to begin work
|
ELE19-03504
| Rough-In Permanent Service | 9/19/2019 | 9/20/2019 | 9/20/2019 8:30:18 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Jeremiah Mitchell... p/s u/g new ok
|
ELE19-03552
| Temporary Service | 9/19/2019 | 9/20/2019 | 9/20/2019 8:14:39 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by ron spen cer.... t/s u/g new ok
|
ELE17-02310
| ELE-Aging Inspection | 9/20/2019 | 9/20/2019 | 9/20/2019 7:19:14 AM | | FAIL |
|
|
contractor is aware and making no attempt to make corrections and schedule inspections
|
ELE17-03288
| ELE-Aging Inspection | 9/20/2019 | 9/20/2019 | 9/20/2019 7:16:08 AM | | PASS |
|
|
permit expired as with building permit
|
ELE17-03288
| DOC - Permit Expired | 9/20/2019 | 9/20/2019 | 9/20/2019 7:15:37 AM | A | PASS |
|
|
building permit expired no inspections scheduled
|
ELE17-03289
| ELE-Aging Inspection | 9/20/2019 | 9/20/2019 | 9/20/2019 7:13:15 AM | | PASS |
|
|
final scheduled
|
ELE17-03289
| Final | 9/20/2019 | 9/20/2019 | 9/20/2019 7:12:58 AM | A | PASS |
|
|
ok to final
|