ELE05-03349
| Final | 9/20/2005 | 9/21/2005 | 9/21/2005 3:59:17 PM | P | NR |
|
|
mitch; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles conference ok
|
ELE05-03408
| Temporary Service | 9/21/2005 | 9/21/2005 | 9/21/2005 3:42:13 PM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 9/21/2005 at 8:17:50 AM. Contact: ###-####. cor. posted called 312.5 needs conn for GEC,406.8 inuse covers, 110.3(B) use manufactures breakers only, 590.6(B)(1) gfci for all 240 V recepts, 110.3 (A) secure all boxes nipples, lock nuts fee due posted
|
ELE05-03375
| Permanent Service | 9/21/2005 | 9/21/2005 | 9/21/2005 2:52:06 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Dana Moyer p/s o/h rec. ok
|
ELE05-03224
| Rough-In Permanent Service | 9/21/2005 | 9/21/2005 | 9/21/2005 2:05:43 PM | P | FAIL |
|
|
henry; Phone #: ###-#### Internet Inspection Request from: Barbara Moore met contractor needs gfci for fan over shower, needs to bond water system to p/s not sub panel , size 1/0, needs inuse covers
|
ELE05-03442
| Rough-In Permanent Service | 9/21/2005 | 9/21/2005 | 9/21/2005 1:54:53 PM | P | FAIL |
|
|
jack ###-#### stop work posted by structural called left message
|
ELE05-03424
| Temporary Service | 9/21/2005 | 9/21/2005 | 9/21/2005 12:12:49 PM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Dana Moyer t/s o/h new ok
|
ELE05-03435
| Temporary Service | 9/20/2005 | 9/21/2005 | 9/21/2005 11:43:50 AM | P | CANC |
|
|
temp pole inspection for afternoon, please; Phone #: ###-#### Internet Inspection Request from: Tawnya McKinney was done in the AM
|
ELE05-02715
| Final | 9/20/2005 | 9/21/2005 | 9/21/2005 11:40:15 AM | A | NH |
|
|
Final reinspection; Phone #: ###-#### Internet Inspection Request from: Radon Elaina called
|
ELE05-03435
| Temporary Service | 9/20/2005 | 9/21/2005 | 9/21/2005 10:50:41 AM | A | FAIL |
|
|
inspection for temp power pole; Phone #: ###-#### Internet Inspection Request from: Tawnya McKinney 110.3 no 1 pole breakers allowed in Milbank called
|
ELE05-02959
| Electrical Rough-In | 9/20/2005 | 9/21/2005 | 9/21/2005 10:29:52 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 9/20/2005 at 2:10:33 PM. Contact: ###-####. ok anop
|
ELE05-03375
| Final | 9/21/2005 | 9/21/2005 | 9/21/2005 9:58:24 AM | P | CANC |
|
|
Phone #: ###-#### Internet Inspection Request from: Dana Moyer Inspection cancelled from web by: Dana Moyer
|
ELE05-03376
| Electrical Rough-In | 9/20/2005 | 9/21/2005 | 9/21/2005 9:50:38 AM | A | PASS |
|
|
###-#### ok
|
ELE05-03424
| Final | 9/21/2005 | 9/21/2005 | 9/21/2005 9:47:22 AM | P | CANC |
|
|
Phone #: ###-#### Internet Inspection Request from: Dana Moyer Inspection cancelled from web by: Dana Moyer
|
ELE05-03417
| Rough-In Permanent Service | 9/20/2005 | 9/21/2005 | 9/21/2005 9:24:50 AM | A | PASS |
|
|
jim; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa r/i ok p/s u/g new ok
|
ELE05-03422
| Rough-In Permanent Service | 9/20/2005 | 9/21/2005 | 9/21/2005 8:41:19 AM | A | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack r/i ok p/s u/g new ok
|
ELE05-02555
| Electrical Rough-In | 9/20/2005 | 9/21/2005 | 9/21/2005 8:40:38 AM | A | FAIL |
|
|
underground inspection for light post//jim; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa do not cover posted over 360 degrees of bends in conduit talked to contractor on site, remove romex from conduit
|
ELE05-03408
| Temporary Service | 9/20/2005 | 9/21/2005 | 9/21/2005 8:08:11 AM | A | NR |
|
|
###-#### no t/s at site
|
ELE05-03376
| Permanent Service | 9/21/2005 | 9/21/2005 | 9/21/2005 12:00:00 AM | A | PASS |
|
|
###-#### r/i ok p/s u/g new ok
|
ELE05-02959
| Final | 9/21/2005 | 9/21/2005 | 9/21/2005 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 9/20/2005 at 2:10:33 PM. Contact: ###-####. ok no card
|
ELE05-03375
| Final | 9/21/2005 | 9/21/2005 | 9/21/2005 12:00:00 AM | P | PASS |
|
|
Phone #: ###-#### Internet Inspection Request from: Dana Moyer ok
|
ELE05-03433
| Permanent Service | 9/20/2005 | 9/21/2005 | 9/20/2005 4:43:53 PM | A | PASS |
|
|
glenn ###-#### p/s u/g new ok
|
ELE05-03432
| Permanent Service | 9/20/2005 | 9/21/2005 | 9/20/2005 1:44:36 PM | A | PASS |
|
|
###-#### glenn p/s u/g new ok
|