Inspections for the day of: Wednesday, September 21, 2005.
Number of inspections: 22
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-03349 Final9/20/20059/21/20059/21/2005 3:59:17 PMPNR
mitch; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles conference ok
ELE05-03408 Temporary Service9/21/20059/21/20059/21/2005 3:42:13 PMPFAIL
Scheduled by a contractor via Hello! on 9/21/2005 at 8:17:50 AM. Contact: ###-####. cor. posted called 312.5 needs conn for GEC,406.8 inuse covers, 110.3(B) use manufactures breakers only, 590.6(B)(1) gfci for all 240 V recepts, 110.3 (A) secure all boxes nipples, lock nuts fee due posted
ELE05-03375 Permanent Service9/21/20059/21/20059/21/2005 2:52:06 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Dana Moyer p/s o/h rec. ok
ELE05-03224 Rough-In Permanent Service9/21/20059/21/20059/21/2005 2:05:43 PMPFAIL
henry; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
met contractor needs gfci for fan over shower, needs to bond water system to p/s not sub panel , size 1/0, needs inuse covers
ELE05-03442 Rough-In Permanent Service9/21/20059/21/20059/21/2005 1:54:53 PMPFAIL
jack ###-#### stop work posted by structural called left message
ELE05-03424 Temporary Service9/21/20059/21/20059/21/2005 12:12:49 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Dana Moyer t/s o/h new ok
ELE05-03435 Temporary Service9/20/20059/21/20059/21/2005 11:43:50 AMPCANC
temp pole inspection for afternoon, please; Phone #: ###-#### Internet Inspection Request from: Tawnya McKinney was done in the AM
ELE05-02715 Final9/20/20059/21/20059/21/2005 11:40:15 AMANH
Final reinspection; Phone #: ###-#### Internet Inspection Request from: Radon Elaina called
ELE05-03435 Temporary Service9/20/20059/21/20059/21/2005 10:50:41 AMAFAIL
inspection for temp power pole; Phone #: ###-#### Internet Inspection Request from: Tawnya McKinney 110.3 no 1 pole breakers allowed in Milbank called
ELE05-02959 Electrical Rough-In9/20/20059/21/20059/21/2005 10:29:52 AMAPASS
Scheduled by a contractor via Hello! on 9/20/2005 at 2:10:33 PM. Contact: ###-####. ok anop
ELE05-03375 Final9/21/20059/21/20059/21/2005 9:58:24 AMPCANC
Phone #: ###-#### Internet Inspection Request from: Dana Moyer Inspection cancelled from web by: Dana Moyer
ELE05-03376 Electrical Rough-In9/20/20059/21/20059/21/2005 9:50:38 AMAPASS
###-#### ok
ELE05-03424 Final9/21/20059/21/20059/21/2005 9:47:22 AMPCANC
Phone #: ###-#### Internet Inspection Request from: Dana Moyer Inspection cancelled from web by: Dana Moyer
ELE05-03417 Rough-In Permanent Service9/20/20059/21/20059/21/2005 9:24:50 AMAPASS
jim; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa r/i ok
p/s u/g new ok
ELE05-03422 Rough-In Permanent Service9/20/20059/21/20059/21/2005 8:41:19 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack r/i ok
p/s u/g new ok
ELE05-02555 Electrical Rough-In9/20/20059/21/20059/21/2005 8:40:38 AMAFAIL
underground inspection for light post//jim; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa do not cover posted over 360 degrees of bends in conduit talked to contractor on site, remove romex from conduit
ELE05-03408 Temporary Service9/20/20059/21/20059/21/2005 8:08:11 AMANR
###-#### no t/s at site
ELE05-03376 Permanent Service9/21/20059/21/20059/21/2005 12:00:00 AMAPASS
###-#### r/i ok p/s u/g new ok
ELE05-02959 Final9/21/20059/21/20059/21/2005 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 9/20/2005 at 2:10:33 PM. Contact: ###-####. ok no card
ELE05-03375 Final9/21/20059/21/20059/21/2005 12:00:00 AMPPASS
Phone #: ###-#### Internet Inspection Request from: Dana Moyer ok
ELE05-03433 Permanent Service9/20/20059/21/20059/20/2005 4:43:53 PMAPASS
glenn ###-#### p/s u/g new ok
ELE05-03432 Permanent Service9/20/20059/21/20059/20/2005 1:44:36 PMAPASS
###-#### glenn p/s u/g new ok