Inspections for the day of: Thursday, September 21, 2006.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-02336 ELE-Aging Inspection9/21/20069/21/20069/27/2006 9:15:04 AM DONE
ELE06-03165 Electrical Rough-In9/21/20069/21/20069/21/2006 3:08:29 PMPPASS
gary; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles r/i ok called needs p/s and 4wire feeds to range and dryer from subpanel also 4wire recepts and pigtails
ELE06-03415 Final9/20/20069/21/20069/21/2006 2:20:25 PMPFAIL
We replaced the existing exterior 100 amp raintight main panel and circuit breakers. Thanks!!! (6090918v).; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell corr. called 250.24 (A)(1) or 104(A)(1) grd or bond water system, 250.64(E) use listed conn. for GEC or plastic conn. 200.6 shall not ID #6or smaller grounded conductor, 250.56 needs 2 grd rods, 250.28 (A&B) install bond screw, 408.4 circuit directory, 110.26 remove all foreign systems from below panel (TV) equip and cables
ELE06-03490 Electrical Rough-In9/21/20069/21/20069/21/2006 1:42:34 PMPPART
any questions please call Dan Wright; Phone #: ###-#### Internet Inspection Request from: Jeff Radford walls ok
ELE06-02491 Final9/21/20069/21/20069/21/2006 1:00:03 PMPFAIL
terry; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr. called 300.4(A)(1)&(D) for flex, 250.24(A)(1) & 110.3(B) shall terminate all GEC at neutral bus not equip grd bus, need power to building for final
ELE06-01294 Permanent Service9/21/20069/21/20069/21/2006 12:35:09 PMPPASS
ty; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles p/s u/g new ok house meter
ELE06-01022 Final9/20/20069/21/20069/21/2006 11:43:36 AMPPASS
jeff - call prior to meet there; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
ELE06-03537 Electrical Rough-In9/21/20069/21/20069/21/2006 11:42:59 AMPFAIL
john; Phone #: ###-#### Internet Inspection Request from: Cathy corr. called 300.4(A)(1)&(D), 314.20 outside boxes shall be flush, remove circ. pump from bath circuit, 334.30 staple romex within 8" of boxes
ELE06-03543 Rough-In Permanent Service9/21/20069/21/20069/21/2006 10:43:31 AMPPASS
rich; Phone #: ###-#### Internet Inspection Request from: Cathy Chilesr/i p/s u/g new ok
ELE05-03669 ELE-Aging Inspection9/21/20069/21/20069/21/2006 10:04:33 AM PART
wsuc
ELE06-03404 Electrical Rough-In9/20/20069/21/20069/21/2006 10:03:54 AMAPART
UFR Inspection; Phone #: ###-#### Internet Inspection Request from: Celinda Winters ok
ELE06-03403 Electrical Rough-In9/20/20069/21/20069/21/2006 10:03:35 AMAPART
Underground conduit inspection; Phone #: ###-#### Internet Inspection Request from: Celinda Winters
ELE06-03399 Rough-In Permanent Service9/21/20069/21/20069/21/2006 9:40:30 AMAPASS
Ceiling cover inspection.; Phone #: ###-#### Internet Inspection Request from: Kathy ok
ELE06-03528 Electrical Rough-In9/20/20069/21/20069/21/2006 9:15:06 AMAPASS
Call Daryl Pewtress 15 minutes before inspecting at ###-#### or ###-####. Work performed by Tom Wonacott.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz
ELE06-03528 DOC - Permit Finaled9/21/20069/21/20069/21/2006 9:14:56 AMAPASS
Call Daryl Pewtress 15 minutes before inspecting at ###-#### or ###-####. Work performed by Tom Wonacott.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz
ELE06-03232 Electrical Rough-In9/20/20069/21/20069/21/2006 8:47:58 AMAPASS
FLOOR COVER ROUGH-IN, PLEASE CONTACT BILL, THANK YOU; Phone #: ###-#### Internet Inspection Request from: Wendy Waters roof top units and pumps on 1st floor ok
ELE06-02685 Electrical Rough-In9/19/20069/21/20069/21/2006 8:03:19 AMAPART
lars - lights; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
spa light potting ok only