Inspections for the day of: Friday, September 21, 2007.
Number of inspections: 10
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-01896 Final9/21/20079/21/20079/21/2007 4:08:49 PMPPART
chris Note: please call 1/2 hr prior to inspection Phone #: ###-#### t/o ok card signed 314.27(D) shall use listed ceiling fan box, or support fan independent of box to structure, 250.148 grd all metal boxes with grd screws, 210.8(B)(2) all recepts in kit shall be gfci protected, 110.2 BCC exhaust fan over over, shall be listed or contr. can field wire light fixtures
ELE07-01691 Final9/21/20079/21/20079/21/2007 1:58:55 PMPPASS
bud ###-#### ok card signed
ELE07-03287 Electrical Rough-In9/21/20079/21/20079/21/2007 1:28:37 PMPFAIL
jo - underground Phone #: ###-#### corr u/g covered before inspection , was not contr fault
ELE07-02083 Final9/21/20079/21/20079/21/2007 12:58:31 PMPPASS
Dan, reinspection; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt ok
ELE07-03071 Conference9/21/20079/21/20079/21/2007 12:36:26 PMPCANC
Requested conference with Bob R. for 12-noon as per Bob''s request with Todd Hall (###-####) Phone #: ###-#### Internet Inspection Request from: Tracy Robertson 315 talked with contr about making corrections as on correction notice, contractor called, said would cancel conference until contractor talked with 324
ELE07-03206 Electrical Rough-In9/20/20079/21/20079/21/2007 11:03:08 AMAFAIL
RON Phone #: ###-#### met owner 14 on 20 amp circuit and box fill
ELE07-03187 Rough-In Permanent Service9/20/20079/21/20079/21/2007 10:31:00 AMAPASS
final on new service and partial rough in on kitchen, any questions call George @ ###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose
partial kit r/i ok for new walls, p/s o/h rec ok
ELE07-02173 Final9/20/20079/21/20079/21/2007 10:04:04 AMAFAIL
DAVE Phone #: ###-#### corr. fee due called 210.52(A) needs outlet liv. rm by fireplace and eating bar wall space, 410.8 clearence for all bed rm closet fixtures, box fill old metal box basement W H drain pump
called left message
ELE06-00711 Electrical Rough-In9/20/20079/21/20079/21/2007 8:55:53 AMAPART
###-#### 5th floor ceilings not ready, 3rd floor booms
ELE07-02016 Final9/20/20079/21/20079/20/2007 2:43:02 PMACANC
Randys cell ###-#### Phone #: ###-#### Internet Inspection Request from: Randy Fletcher Inspection cancelled from web by: Randy Fletcher