ELE12-02592
| ELE-Aging Inspection | 9/21/2015 | 9/21/2015 | 9/22/2015 2:37:12 PM | | DONE |
|
|
Waiting on owner
|
ELE12-02616
| ELE-Aging Inspection | 9/21/2015 | 9/21/2015 | 9/22/2015 2:35:46 PM | | DONE |
|
|
Waiting on owner
|
ELE15-02553
| Final | 9/21/2015 | 9/21/2015 | 9/21/2015 2:38:35 PM | P | PASS |
|
|
Final inspection please. Contact is David Forbes ###-####. Please call if you have any questions as he will not be on site. Thank you and have a super day! Phone #: ###-#### Inspection requested via web by Laura Longshaw Final ok
|
ELE15-02974
| Rough-In Permanent Service | 9/21/2015 | 9/21/2015 | 9/21/2015 2:22:03 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Brad Girard Full house rough in ok cover p/s o/h rec ok
|
ELE15-03010
| Electrical Rough-In | 9/21/2015 | 9/21/2015 | 9/21/2015 1:44:45 PM | P | PASS |
|
|
Please provide wall cover inspection in suite 115. Call Sean at ###-#### about 1/2 an hour prior to inspection, so I can meet you there. Thanks, Sean Phone #: ###-#### Inspection requested via web by Kevin Perez Wall separating offices 228 and 229, walls for new office 234 rough in ok cover
|
ELE15-03009
| Electrical Rough-In | 9/21/2015 | 9/21/2015 | 9/21/2015 1:20:45 PM | P | PASS |
|
|
Please provide wall cover inspection in suite 107. Call Sean at ###-#### about 1/2 an hour prior to inspection, so I can meet you there. Thanks, Sean Phone #: ###-#### Inspection requested via web by Kevin Perez Wall seperating offices 304 and 305 rough in ok cover
|
ELE15-02615
| Electrical Rough-In | 9/21/2015 | 9/21/2015 | 9/21/2015 12:49:49 PM | P | FAIL |
|
|
Electrical rough in for relocated walls Phone #: ###-#### Inspection requested via web by Zane Robertson 400.8(2)- Flexible cords shall not be ran through holes in walls. 517.13- Branch circuits serving patient care areas shall be provided with and effective ground fault path by installation in a metal raceway system, or cable having a metal armor or sheath assembly.
|
ELE15-02985
| Electrical Rough-In | 9/17/2015 | 9/21/2015 | 9/21/2015 10:42:29 AM | A | PART |
|
|
Part rough in // Mark Phone #: ###-#### Demizing wall only rough in ok cover
|
ELE15-03003
| Temporary Service | 9/20/2015 | 9/21/2015 | 9/21/2015 9:44:51 AM | A | PASS |
|
|
Overhead service pole is in the back yard fire damaged house Phone #: ###-#### Inspection requested via web by Don Conley t/s o/h n ok
|
ELE15-02331
| Final | 9/20/2015 | 9/21/2015 | 9/21/2015 9:27:50 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by daniel bibikov Final ok
|
ELE15-02993
| Final | 9/18/2015 | 9/21/2015 | 9/21/2015 8:21:20 AM | A | PASS |
|
|
Tom Phone #: ###-#### All wiring fished in to new outlets. Final ok
|
ELE15-03000
| Electrical Rough-In | 9/21/2015 | 9/21/2015 | 9/21/2015 12:00:00 AM | P | PASS |
|
|
|