Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE18-03607 Electrical Rough-In9/21/20189/21/20189/21/2018 3:04:22 PMPPASS
Can you come toward the end of your rounds so I can finish making up some boxes thanks Phone #: ###-#### Inspection requested via web by Ron Zimmerman
Covered awning ceiling rough in ok cover
ELE17-03734 Conference9/21/20189/21/20189/21/2018 2:53:03 PMPPASS
Spoke with general foreman on site. All work performed after 9-14-18 must be done and permitted by a licenced contractor due to original contractor no longer in business.
ELE17-02862 Permanent Service9/21/20189/21/20189/21/2018 2:23:16 PMPPASS
Call Craig Phone #: ###-#### Inspection requested via web by Tom Betty
86,448 AIC value provided on print.
p/s u/g n ok
ELE18-03320 Electrical Rough-In9/21/20189/21/20189/21/2018 1:43:17 PMPPASS
Phone #: ###-#### Inspection requested via web by Kerri Hamilton
Level 4 interior walls rough in ok cover
ELE18-03048 Final9/20/20189/21/20189/21/2018 12:24:25 PMAFAIL
Please use side gate for entry if no one is home Phone #: ###-#### Inspection requested via web by Robert Carter
210.8(A)(2)- All receptacles located in hobby room shall have GFCI protection. Refer/ freezer.
406.9(A)- All receptacles installed outdoors in damp or wet locations shall be weather resistant type.
406.12- All receptacles installed in addition to residential garage shall be tamper resistant type.
ELE18-03320 Electrical Rough-In9/20/20189/21/20189/21/2018 11:06:38 AMPCANC
Phone #: ###-#### >> Inspection requested via web by Kerri Hamilton Inspection cancelled from web by: Kerri Hamilton
ELE18-03277 Final9/20/20189/21/20189/21/2018 10:53:54 AMAPASS
Phone #: ###-#### Inspection requested via web by BRS Permitting Final ok
ELE18-03202 Electrical Rough-In9/20/20189/21/20189/21/2018 10:22:52 AMAPASS
Request for cover Phone #: ###-#### Inspection requested via web by Tyler Ridley
Check notes on ELE18-03086. Underground in slab Phone #: ###-#### Inspection requested via web by Kotton Corder
Spoke with electrical contractor and owner as per NEC 511.3 to declassify minor repair garage and office areas minimum ventilation 4 or more air exchanges per hour with supply and outlet with in 12" of floor shall be provided by final so no electrical issues remain. Stamped Documentation must be provided. Under slab rough in for garage area rough in ok cover.
New contractor taking over job.
Office walls only rough in ok cover
ELE18-03562 Final9/20/20189/21/20189/21/2018 9:48:16 AMANH
Please call Brodie at ###-#### with any questions. Phone #: ###-#### Inspection requested via web by William Salts
No answer at door, left notice to call and reschedule
ELE18-01608 Electrical Rough-In9/20/20189/21/20189/21/2018 9:29:33 AMAPASS
Phone #: ###-#### Inspection requested via web by Jeremy Cloud
Underground E.O. Wilson common area rough in ok cover
ELE18-02584 Final9/20/20189/21/20189/20/2018 3:40:46 PMAPART
Contact Jon Novak
Thank you, Phone #: ###-#### Inspection requested via web by Tom Betty
Phase 1 TCO. No card posted. Temp final ok