ELE05-00657
| Electrical Rough-In | 9/22/2005 | 9/22/2005 | 9/22/2005 9:21:54 PM | P | FAIL |
|
|
Scheduled by a contractor via Hello! on 9/22/2005 at 8:53:31 AM. Contact: ###-####. 1. 210.52- 2' 6' 12' rule in all the rooms 2. 300.14- 6'' of free conductor in most boxes 3. 334.30- securing and supporting of cables. 4. 300.4- 1 1/4" protection against physical damage. 5. 314.17- conductors shall be fastened within 8" of box.
|
ELE05-03471
| Conference | 9/22/2005 | 9/22/2005 | 9/22/2005 9:15:33 PM | P | DONE |
|
|
please call prior to inspection don ###-#### had confrence about the service with the homeowner. He will finish the in and then call for a p/s ri inspection.
|
ELE05-03457
| Permanent Service | 9/22/2005 | 9/22/2005 | 9/22/2005 3:05:46 PM | P | NR |
|
|
mark; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
ELE04-01545
| Final | 9/21/2005 | 9/22/2005 | 9/22/2005 2:50:21 PM | P | PASS |
|
|
mike; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
ELE05-03135
| Electrical Rough-In | 9/21/2005 | 9/22/2005 | 9/22/2005 1:52:59 PM | P | PASS |
|
|
EQUIPOTENTAL GRID; Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack grid ok for concrete
|
ELE05-03281
| Electrical Rough-In | 9/22/2005 | 9/22/2005 | 9/22/2005 1:34:34 PM | P | CANC |
|
|
jack; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
ELE05-03471
| Rough-In Permanent Service | 9/22/2005 | 9/22/2005 | 9/22/2005 1:06:32 PM | P | NR |
|
|
please call prior to inspection don ###-####
|
ELE05-01294
| Final | 9/22/2005 | 9/22/2005 | 9/22/2005 12:37:44 PM | P | CANC |
|
|
###-####
|
ELE05-03462
| Final | 9/21/2005 | 9/22/2005 | 9/22/2005 12:21:00 PM | P | CANC |
|
|
###-#### - dave Note: trench for exterior fountain wrong type insp
|
ELE05-03236
| Permanent Service | 9/21/2005 | 9/22/2005 | 9/22/2005 10:28:18 AM | A | PASS |
|
|
New service inspection only at this time.; Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot p/s u/g n/r ok
|
ELE05-02233
| Rough-In Permanent Service | 9/21/2005 | 9/22/2005 | 9/22/2005 10:06:48 AM | A | PASS |
|
|
bob; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ri ok p/s o/h n ok
|
ELE05-02233
| Electrical Rough-In | 9/21/2005 | 9/22/2005 | 9/22/2005 9:55:50 AM | A | CANC |
|
|
bob; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
ELE05-03431
| Temporary Service | 9/22/2005 | 9/22/2005 | 9/22/2005 9:48:09 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 9/22/2005 at 6:38:42 AM. Contact: ###-####. t/s o/h n ok
|
ELE05-03457
| Permanent Service | 9/21/2005 | 9/22/2005 | 9/22/2005 9:46:26 AM | A | NH |
|
|
mark ###-#### no access to see what the new service is feeding
|
ELE05-01470
| Final | 9/21/2005 | 9/22/2005 | 9/22/2005 9:27:49 AM | A | PASS |
|
|
ron; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
ELE05-03462
| Electrical Rough-In | 9/22/2005 | 9/22/2005 | 9/22/2005 12:00:00 AM | P | PASS |
|
|
###-#### - dave Note: trench for exterior fountain ok for cover
|
ELE05-03281
| Conference | 9/22/2005 | 9/22/2005 | 9/22/2005 12:00:00 AM | P | DONE |
|
|
jack; Phone #: ###-#### Internet Inspection Request from: Barbara Moore had confrence with home owner, he agreed that he needs to hire a contractor to do the work. He has a book and has read it but has no idea what he is doing. To many violations to even think about.
|