Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-00657 Electrical Rough-In9/22/20059/22/20059/22/2005 9:21:54 PMPFAIL
Scheduled by a contractor via Hello! on 9/22/2005 at 8:53:31 AM. Contact: ###-####.
1. 210.52- 2' 6' 12' rule in all the rooms
2. 300.14- 6'' of free conductor in most boxes
3. 334.30- securing and supporting of cables.
4. 300.4- 1 1/4" protection against physical damage.
5. 314.17- conductors shall be fastened within 8" of box.
ELE05-03471 Conference9/22/20059/22/20059/22/2005 9:15:33 PMPDONE
please call prior to inspection don ###-####
had confrence about the service with the homeowner. He will finish the in and then call for a p/s ri inspection.
ELE05-03457 Permanent Service9/22/20059/22/20059/22/2005 3:05:46 PMPNR
mark; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
ELE04-01545 Final9/21/20059/22/20059/22/2005 2:50:21 PMPPASS
mike; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
ELE05-03135 Electrical Rough-In9/21/20059/22/20059/22/2005 1:52:59 PMPPASS
EQUIPOTENTAL GRID; Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack
grid ok for concrete
ELE05-03281 Electrical Rough-In9/22/20059/22/20059/22/2005 1:34:34 PMPCANC
jack; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
ELE05-03471 Rough-In Permanent Service9/22/20059/22/20059/22/2005 1:06:32 PMPNR
please call prior to inspection don ###-####
ELE05-01294 Final9/22/20059/22/20059/22/2005 12:37:44 PMPCANC
###-####
ELE05-03462 Final9/21/20059/22/20059/22/2005 12:21:00 PMPCANC
###-#### - dave Note: trench for exterior fountain
wrong type insp
ELE05-03236 Permanent Service9/21/20059/22/20059/22/2005 10:28:18 AMAPASS
New service inspection only at this time.; Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot
p/s u/g n/r ok
ELE05-02233 Rough-In Permanent Service9/21/20059/22/20059/22/2005 10:06:48 AMAPASS
bob; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
ri ok
p/s o/h n ok
ELE05-02233 Electrical Rough-In9/21/20059/22/20059/22/2005 9:55:50 AMACANC
bob; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
ELE05-03431 Temporary Service9/22/20059/22/20059/22/2005 9:48:09 AMAPASS
Scheduled by a contractor via Hello! on 9/22/2005 at 6:38:42 AM. Contact: ###-####.
t/s o/h n ok
ELE05-03457 Permanent Service9/21/20059/22/20059/22/2005 9:46:26 AMANH
mark ###-####
no access to see what the new service is feeding
ELE05-01470 Final9/21/20059/22/20059/22/2005 9:27:49 AMAPASS
ron; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
ELE05-03462 Electrical Rough-In9/22/20059/22/20059/22/2005 12:00:00 AMPPASS
###-#### - dave Note: trench for exterior fountain
ok for cover
ELE05-03281 Conference9/22/20059/22/20059/22/2005 12:00:00 AMPDONE
jack; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
had confrence with home owner, he agreed that he needs to hire a contractor to do the work. He has a book and has read it but has no idea what he is doing. To many violations to even think about.