Inspections for the day of: Monday, September 22, 2008.
Number of inspections: 12
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-02585 Conference9/22/20089/22/20089/22/2008 3:22:24 PMPDONE
jerod Note: please call 1/2 hr prior to inspection Phone #: ###-#### - units 755 &
correct box fill outlet spacing remove range hood from SABC, connectors for all boxes
ELE08-02585 Electrical Rough-In9/22/20089/22/20089/22/2008 3:21:11 PMPFAIL
jerod Note: please call 1/2 hr prior to inspection Phone #: ###-#### corr for service shall grd and bond u/g pipe, hot and cold, jumpers around isolated metal pipe,, calc service
ELE08-02267 Permanent Service9/22/20089/22/20089/22/2008 2:05:36 PMPPASS
Added house panel on exterior. Phone #: ###-#### Internet Inspection Request from: Joe Thomas p/s u/g new for house meter ok
ELE08-02587 Electrical Rough-In9/22/20089/22/20089/22/2008 2:05:09 PMPPART
Cover for walls and ceilings. All ceilings to be drop accoustical except (2) high ceilings with barrel arches. Phone #: ###-#### Internet Inspection Request from: Joe Thomas walls hard ceiling , u/g
ELE08-01677 Final9/22/20089/22/20089/22/2008 1:05:17 PMPPASS
ELE08-02029 Final9/22/20089/22/20089/22/2008 12:45:19 PMPPASS
roger Phone #: ###-#### ok card signed
ELE08-02029 Electrical Rough-In9/22/20089/22/20089/22/2008 12:44:58 PMPPASS
roger Phone #: ###-#### grid ceiling ok
ELE07-02663 DOC - Permit Expired9/22/20089/22/20089/22/2008 11:53:14 AMPPASS
contr said corrections made
ELE07-02663 ELE-Aging Inspection9/22/20089/22/20089/22/2008 11:52:45 AM DONE
ESC08-00571 General Inspection9/22/20089/22/20089/22/2008 9:58:02 AMAPART
ok
ELE08-02581 Rough-In Permanent Service9/19/20089/22/20089/22/2008 9:49:15 AMAPART
john Phone #: ###-#### r/i only ok corr posted needs other systems grd bus, staple cables within 8" and u/g from house too shop installed no permit or inspection by owner
ELE08-01952 Final9/19/20089/22/20089/22/2008 8:46:18 AMAFAIL
Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack called left message, corr. BCC ans 110.2 listing of equip. , electric gates, field evaluated sticker no record of it to J Schmer, looks like someone just stuck the sticker on equip, 314.3 metallic raceway and fitting not allowed at sprinkler time clock