Inspections for the day of: Thursday, September 22, 2016.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJim Storey
TitleBLD-COM/RES INSPECTOR
Phone #794-9490
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
BLD16-02042 BLD-Final9/22/20169/22/20169/23/2016 4:19:59 PMPDONE
We are complete with this re-roof project. Contact Micron if you need to inspect. Phone #: ###-#### Inspection requested via web by Leslee Shuter
BLD16-02385 BLD-Framing/Rough-in9/22/20169/22/20169/22/2016 3:20:51 PMPFAIL
Phil Phone #: ###-#### Phil Phone #: ###-####CUTTING, NOTCHING AND DRILLING

R502.8.1 Sawn lumber.
Notches in solid lumber joists, rafters and beams shall not exceed one-sixth of the depth of the member, shall not be longer than one-third of the depth of the member and shall not be located in the middle one-third of the span. Notches at the ends of the member shall not exceed one-fourth the depth of the member. The tension side of members 4 inches (102 mm) or greater in nominal thickness shall not be notched except at the ends of the members. The diameter of holes bored or cut into members shall not exceed one-third the depth of the member. Holes shall not be closer than 2 inches (51 mm) to the top or bottom of the member, or to any other hole located in the member. Where the member is also notched, the hole shall not be closer than 2 inches (51 mm) to the notch.
truss engineering
BLD16-02382 BLD-Framing/Rough-in9/22/20169/22/20169/22/2016 3:20:24 PMPFAIL
Phil Phone #: ###-####CUTTING, NOTCHING AND DRILLING

R502.8.1 Sawn lumber.
Notches in solid lumber joists, rafters and beams shall not exceed one-sixth of the depth of the member, shall not be longer than one-third of the depth of the member and shall not be located in the middle one-third of the span. Notches at the ends of the member shall not exceed one-fourth the depth of the member. The tension side of members 4 inches (102 mm) or greater in nominal thickness shall not be notched except at the ends of the members. The diameter of holes bored or cut into members shall not exceed one-third the depth of the member. Holes shall not be closer than 2 inches (51 mm) to the top or bottom of the member, or to any other hole located in the member. Where the member is also notched, the hole shall not be closer than 2 inches (51 mm) to the notch.
truss engineering
BLD16-03088 BLD-Framing/Rough-in9/22/20169/22/20169/22/2016 2:43:32 PMPPASS
Lockbox is at front door, home is vacant, plans are on fireplace hearth. Additional framing completed due to rotted wood found not on plans in master. If possible please call at least 30 mins before arriving so I can meet you there for any issues. Thanks!! Phone #: ###-#### Inspection requested via web by Andrew George
BLD16-02267 BLD-Conference9/22/20169/22/20169/22/2016 2:24:26 PMPPASS
Building Final-afternoon Please, Thank You Phone #: ###-#### Inspection requested via web by Ron Oswald need unlock door sign
BLD16-01301 BLD-Final9/21/20169/22/20169/22/2016 11:22:37 AMAPASS
Scott Phone #: ###-####
BLD16-01301 DOC - Permit Finaled9/22/20169/22/20169/22/2016 11:22:26 AMPPASS
BLD16-02042 DOC - Permit Finaled9/22/20169/22/20169/22/2016 11:21:46 AMPPASS
BLD16-00004 BLD-Final9/21/20169/22/20169/22/2016 11:03:10 AMAPASS
Daniel Phone #: ###-####
BLD16-00004 DOC - Permit Finaled9/22/20169/22/20169/22/2016 11:02:57 AMPPASS
BLD16-00978 BLD-Final9/20/20169/22/20169/22/2016 10:46:10 AMAFAIL
Phone #: ###-#### Inspection requested via web by Franz Witte no ele permit or insp
BLD16-02438 BLD-Final9/21/20169/22/20169/22/2016 10:01:59 AMAPASS
Call prior to going Phone #: 4071413 >> Inspection requested via mobile web by Joe Atalla
BLD16-02438 DOC - Permit Finaled9/22/20169/22/20169/22/2016 10:01:19 AMPPASS
BLD15-01997 BLD-Energy code compliance9/22/20169/22/20169/22/2016 9:32:08 AMAPASS
As early as possible Phone #: 3852260488 >> Inspection requested via mobile web by Arn Kniffen foam insulation at grade ok to cover exterior permiter of building
BLD15-01997 BLD-Conference9/22/20169/22/20169/22/2016 6:40:10 AMACANC
>> Inspection requested via mobile web by Arn Kniffen Inspection cancelled via mobile web on Thursday, September 22, 2016.