ELE05-03482
| Temporary Service | 9/23/2005 | 9/23/2005 | 9/23/2005 2:58:51 PM | P | PASS |
|
|
###-#### - tharon t/s u/g new ok
|
ELE05-03481
| Temporary Service | 9/23/2005 | 9/23/2005 | 9/23/2005 2:58:22 PM | P | PASS |
|
|
###-#### - tharon t/s u/g new ok
|
ELE05-03215
| Rough-In Permanent Service | 9/23/2005 | 9/23/2005 | 9/23/2005 2:05:06 PM | P | PART |
|
|
Underground Inspection ; Phone #: ###-#### Internet Inspection Request from: Cathy Felin u/g for pole lights ok, and bases
|
ELE02-02940
| ELE-Request for Extension | 9/23/2005 | 9/23/2005 | 9/23/2005 1:22:03 PM | P | PART |
|
|
###-#### - dave Note: ran out of money finally able to plum, elect, bldg and mech this is the last time permit can be extented,talked with owner about the electrical contractor he going to have take over job, note there may be more work , and if owner does work he will have to update his permit
|
ELE05-03484
| Electrical Rough-In | 9/23/2005 | 9/23/2005 | 9/23/2005 12:42:11 PM | P | FAIL |
|
|
trench inspection//gayle; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa conference ok only owner needs concrete encased electrode at new shop, and u/g, has over 360 degrees of bends, and shall be 18" below grade where not under concrete
|
ELE05-03384
| Electrical Rough-In | 9/23/2005 | 9/23/2005 | 9/23/2005 12:15:09 PM | P | FAIL |
|
|
shawn; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles cor. called needs approved fittings for LFNC, 356.42
|
ELE05-03226
| Permanent Service | 9/22/2005 | 9/23/2005 | 9/23/2005 10:42:02 AM | A | PASS |
|
|
between 9:00 and 11:30 p/s o/h rec. ok
|
ELE05-03021
| Final | 9/22/2005 | 9/23/2005 | 9/23/2005 10:09:35 AM | A | FAIL |
|
|
olga; Phone #: ###-#### Internet Inspection Request from: Barbara Moore cor. not made called left message 300.11 support wires for cables shall be secured at both ends
|
ELE05-03475
| Temporary Service | 9/22/2005 | 9/23/2005 | 9/23/2005 9:42:49 AM | A | PASS |
|
|
rock ###-#### t/s u/g new ok
|
ELE05-03444
| Temporary Service | 9/22/2005 | 9/23/2005 | 9/23/2005 9:42:26 AM | A | PASS |
|
|
rock; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa t/s u/g new ok
|
ELE05-03476
| Temporary Service | 9/22/2005 | 9/23/2005 | 9/23/2005 9:42:02 AM | A | PASS |
|
|
rock ###-####t/s u/g new ok
|
ELE05-01479
| Final | 9/22/2005 | 9/23/2005 | 9/23/2005 9:09:01 AM | A | FAIL |
|
|
steve ###-#### or ###-#### cor. posted met owner 408.4 label circuits in p/s 410.30 (C) discharge fixtures shall be located diectly below outlet, complete all wiring WH
|
ELE05-02267
| ELE-Aging Inspection | 9/23/2005 | 9/23/2005 | 9/23/2005 8:32:09 AM | | FAIL |
|
|
cor. posted 300.10&12 raceways shall be complete from u/g conduit to sign , needs permit and electrical contractor, and uncover all u/g covered before inspection
|
ELE05-03226
| Final | 9/23/2005 | 9/23/2005 | 9/23/2005 12:00:00 AM | A | PASS |
|
|
between 9:00 and 11:30 ###-#### ok
|