Inspections for the day of: Tuesday, September 23, 2008.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ESC07-00913 General Inspection9/23/20089/23/20089/23/2008 3:56:33 PMPPART
looked ok
ESC08-00518 General Inspection9/23/20089/23/20089/23/2008 3:55:46 PMPPART
looked ok
ESC08-00562 General Inspection9/23/20089/23/20089/23/2008 3:54:51 PMPPART
looked ok
ESC08-00549 General Inspection9/23/20089/23/20089/23/2008 3:54:02 PMAPART
looked ok
ELE08-00605 Final9/23/20089/23/20089/23/2008 3:53:14 PMPPASS
keith - please call for access Phone #: ###-#### ok to final, no esc this project
ELE08-02560 Electrical Rough-In9/23/20089/23/20089/23/2008 3:30:12 PMPPASS
Scheduled by a contractor via Hello! on 9/23/2008 at 10:15:30 AM. Contact: ###-####. ok to backfill gec
ELE08-02556 Rough-In Permanent Service9/23/20089/23/20089/23/2008 2:42:16 PMPFAIL
Phone #: ###-#### Internet Inspection Request from: Cevyn Recla called left correction notice, NEC 110.12(B) panel shall not be damaged, nor cable over sub-panel, 334.30 shall secure ser by approved means and also nm in up bath shall be secured witin 12 of box, 210.52(E)(1) shall provide receptacle at front of dwelling, 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing member-kitchen,BCC shall provide box for range, shall remove sub-panel from closet
ELE08-00026 Electrical Rough-In9/23/20089/23/20089/23/2008 1:19:40 PMPPART
Ken Phone #: ###-#### peninsula backsplash only ok to cover, kitchen
ELE08-02568 Electrical Rough-In9/23/20089/23/20089/23/2008 12:29:38 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Jim Williams walls only mok to cover, no esc this project
ELE08-02574 Temporary Service9/23/20089/23/20089/23/2008 10:38:21 AMPPASS
Tollie Phone #: ###-#### t/s u/g n ok
ELE08-02370 Electrical Rough-In9/22/20089/23/20089/23/2008 9:45:00 AMAPASS
Inspection called for ground ring/grounding.

Call if you have any questions. Phone #: ###-#### Internet Inspection Request from: Donovan Waldenmyer ok to cover ground ring
ELE06-02420 Final9/23/20089/23/20089/23/2008 9:06:20 AMAPASS
ok to final, no esc this project
ELE06-01418 Final9/23/20089/23/20089/23/2008 9:04:48 AMAPASS
ok to final, no esc this project
ELE08-02585 Electrical Rough-In9/22/20089/23/20089/23/2008 8:29:10 AMAPASS
jared - please call 1/2 hr prior Phone #: ###-#### corrections made, ok to cover 755 and 757 only, look at power later, no esc this project