ELE12-01183
| ELE-Aging Inspection | 9/23/2013 | 9/23/2013 | 9/25/2013 1:48:06 PM | | DONE |
|
|
Homeowner will call for final
|
ELE13-02453
| Electrical Rough-In | 9/20/2013 | 9/23/2013 | 9/23/2013 2:32:49 PM | P | NR |
|
|
After 3:00 pm please-John Phone #: ###-#### Not ready
|
ELE11-02093
| Final | 9/19/2013 | 9/23/2013 | 9/23/2013 2:06:58 PM | P | PASS |
|
|
Please call homeowner about 30 minutes early. ###-#### or ###-#### Phone #: ###-#### >> Inspection requested via web by William Andrews job complete, final ok
|
ELE13-02612
| Final | 9/22/2013 | 9/23/2013 | 9/23/2013 1:39:33 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Dan Hobdey correction done, final ok
|
ELE13-01948
| Final | 9/20/2013 | 9/23/2013 | 9/23/2013 1:27:23 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by David Nelson final ok
|
ELE13-02497
| Final | 9/22/2013 | 9/23/2013 | 9/23/2013 12:35:32 PM | A | FAIL |
|
|
panel changed Phone #: ###-#### >> Inspection requested via web by Robert Carter NEC 110.26(A) Working space for service equipment, NEC 408.4 complete panel directory circiuts #13 & 19 Bond hot and cold water pipes at water heater
|
ELE13-02627
| Final | 9/23/2013 | 9/23/2013 | 9/23/2013 11:02:19 AM | P | CANC |
|
|
Contact: Brian Gee, fairly late afternoon inspection please Phone #: ###-#### >> Inspection requested via web by Deb Gooden Inspection cancelled from web by: Deb Gooden
|
ELE13-02428
| Conference | 9/19/2013 | 9/23/2013 | 9/23/2013 10:41:12 AM | A | DONE |
|
|
mike Phone #: ###-#### Discussed grounding for separately derived system,from generator with transfer switch.Common building grounding,supplemental electrode required
|
ELE13-02619
| Electrical Rough-In | 9/20/2013 | 9/23/2013 | 9/23/2013 10:25:49 AM | A | PASS |
|
|
need ok to cover in two new bathrooms Phone #: ###-#### >> Inspection requested via web by Dan Hobdey rough-in ok cover
|
ELE13-02617
| Final | 9/20/2013 | 9/23/2013 | 9/23/2013 9:45:49 AM | A | PASS |
|
|
Contact Vince ###-#### Phone #: ###-#### >> Inspection requested via web by Clint Tate final ok
|
ELE13-02617
| Electrical Rough-In | 9/23/2013 | 9/23/2013 | 9/23/2013 9:44:04 AM | P | PASS |
|
|
Contact Vince ###-#### Phone #: ###-#### >> Inspection requested via web by Clint Tate rough-in ok
|
ELE13-02232
| Rough-In Permanent Service | 9/19/2013 | 9/23/2013 | 9/23/2013 9:07:08 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Tracy Robertson rough-in p/s u/g n ok
|
ELE13-01457
| Final | 9/23/2013 | 9/23/2013 | 9/23/2013 8:25:11 AM | A | FAIL |
|
|
We are requesting a partial final. This would be a final for the building only with site to follow later. Contact is Jay Sprik. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery NEC 210.8(B) All 125 Volt single phase, 15 and 20 ampere receptacles in kitchens shall have GFCI protection for personal. NEC 422.51 Cord and plug connected vending machines require GFCI protection NEC 406.(B) listed weather resistant receptacle, roof top service receptacle
|