Inspections for the day of: Wednesday, September 23, 2015.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-01131 ELE-Aging Inspection9/23/20159/23/20159/25/2015 11:11:09 AM CANC
too busy
ELE12-01900 ELE-Aging Inspection9/23/20159/23/20159/25/2015 11:10:43 AM CANC
too busy
ELE15-02825 Electrical Rough-In9/22/20159/23/20159/23/2015 2:58:14 PMPPASS
Phone #: ###-#### Very nice work no conference needed. M. bath, new closet, kitchen remodel, new utility room rough in ok cover
ELE15-02914 Final9/18/20159/23/20159/23/2015 2:36:57 PMPPASS
Please call homeowner, Leslie Criner; 30 min prior to arrival at ###-#### Phone #: ###-#### Inspection requested via web by Louis Keller Final ok
ELE15-03039 Electrical Rough-In9/22/20159/23/20159/23/2015 2:05:31 PMPPASS
The Suite # is 109. It is between Edible Arrangements and Blimpie. The key is in the mailbox on the wall and is marked 108. Phone #: ###-#### Inspection requested via web by Craig Korell Wall dividing front area from dance area rough in ok cover.
ELE15-02264 Final9/23/20159/23/20159/23/2015 1:49:31 PMPFAIL
Phone #: ###-#### Inspection requested via web by daniel bibikov
110.3 Patio receptacle not working unit 101
ELE15-02525 Final9/23/20159/23/20159/23/2015 1:01:58 PMPFAIL
The side garage door is unlocked for inspections Phone #: ###-#### Inspection requested via web by Brad Baker
210.8(A)(6)- All receptacles located in kitchen that serve counter top area shall have GFCI protection.
422.30- All appliances shall have a disconnecting means.
ELE15-02880 Rough-In Permanent Service9/23/20159/23/20159/23/2015 12:45:19 PMPPASS
Phone #: ###-#### Inspection requested via web by Bob Glenn Rough in ok cover p/s u/g n ok
ELE15-01067 Electrical Rough-In9/23/20159/23/20159/23/2015 12:22:30 PMPPASS
Phone #: ###-#### Inspection requested via web by kendall bender Discussed with contractor required show window receptacles, He stated conduits in place asked to check on final. Showroom grid rough in ok cover
ELE15-03038 Rough-In Permanent Service9/22/20159/23/20159/23/2015 11:10:49 AMAPASS
Phone #: ###-#### Inspection requested via web by kevin blackmon Underground to service not in at time of inspection Rough in ok cover p/s u/g n ok
ELE15-01892 Final9/22/20159/23/20159/23/2015 10:30:10 AMAPART
Mark-wants Temp CO Phone #: ###-#### North side ventalation provided, south not ventalated. All electrical located above classified areas. Need finish sign and pour seal offs for paint booth. Temp final ok
ELE15-03030 Temporary Service9/23/20159/23/20159/23/2015 9:54:20 AMAFAIL
call dene with any questions
thank you Phone #: ###-#### Inspection requested via web by kim grundhauser
250.50- Where grounding electode system is not present one shall be provided. Must see connection to grounding electrode system prior to connection of service
ELE15-02482 Electrical Rough-In9/22/20159/23/20159/23/2015 9:09:21 AMAPASS
Ceiling cover Phone #: ###-#### Inspection requested via web by Thomas Jenkins Grid rough in ok cover
ELE15-02482 Electrical Rough-In9/23/20159/23/20159/23/2015 9:07:31 AMPFAIL
Ceiling cover Phone #: ###-#### Inspection requested via web by Thomas Jenkins 314.16- Boxes shall be of an approved size to provide free space for all enclosed conductors. Prefab wall behind cook station.
ELE15-02035 Final9/22/20159/23/20159/23/2015 8:22:39 AMAPASS
Roger Phone #: ###-#### Final ok