ELE17-03321
| ELE-Aging Inspection | 9/23/2019 | 9/23/2019 | 9/26/2019 6:10:11 AM | | DONE |
|
|
Please schedule a final inspection. Will need to see 1 ea components installed and paperwork showing model numbers. For future inspections, a RI inspection must be performed prior to installation of any components.
|
ELE19-03580
| Electrical Rough-In | 9/20/2019 | 9/23/2019 | 9/23/2019 2:14:20 PM | P | PASS |
|
|
I,Greg, will be out of town. This is Nicks Number Phone #: ###-#### Inspection requested via web by Greg Idsinga Ok cover upstairs E side, and downstairs laundry, bed bath.
|
ELE19-03592
| Rough-In Permanent Service | 9/23/2019 | 9/23/2019 | 9/23/2019 2:13:36 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Robert Murray Ok cover. p/s u/g n ok
|
ELE19-03581
| Final | 9/20/2019 | 9/23/2019 | 9/23/2019 12:31:49 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Tricia Henderson p/s o/h n ok
|
ELE19-02954
| Electrical Rough-In | 9/22/2019 | 9/23/2019 | 9/23/2019 9:51:11 AM | A | FAIL |
|
|
Text or call please when you are on the way. Phone #: ###-#### Inspection requested via web by Josh Reeder 1.Stapling needed above boxes. 2. 20a circuit needed for bathrooms and laundry. 3. All grounds and neutrals need made up in all boxes. 4. Some boxes need replaced to a larger size to allow for box fill.
|
ELE19-02878
| Electrical Rough-In | 9/20/2019 | 9/23/2019 | 9/23/2019 9:47:35 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Donald Sorrells Ok cover upstairs
|
ELE19-03402
| Electrical Rough-In | 9/22/2019 | 9/23/2019 | 9/23/2019 8:48:25 AM | A | PASS |
|
|
equipotential plane, potting of pool lights, and bonding volleyball anchors for new pool construction Phone #: ###-#### Inspection requested via web by Jordan Camie Volleyball pockets, eq plane and potting ok cover
|
ELE19-02954
| Electrical Rough-In | 9/23/2019 | 9/23/2019 | 9/23/2019 4:21:56 AM | A | CANC |
|
|
Text or call please when you are on the way. Phone #: ###-#### >> Inspection requested via web by Josh Reeder Inspection cancelled from web by: Josh Reeder
|