ELE08-01055
| ELE-Aging Inspection | 9/24/2008 | 9/24/2008 | 10/1/2008 8:40:04 AM | | DONE |
|
|
|
ELE08-01461
| Final | 9/24/2008 | 9/24/2008 | 9/24/2008 3:36:52 PM | P | CANC |
|
|
Phone #: ###-#### Internet Inspection Request from: Kerri Hamilton called contr will reschedule
|
ELE08-02597
| Electrical Rough-In | 9/24/2008 | 9/24/2008 | 9/24/2008 3:24:45 PM | P | PART |
|
|
This is a trench inspection for the underground electrical conduit for the remodeled drive-thru area. Need inspected so we can cover. Contact is Brian Cornell. Phone #: ###-#### Internet Inspection Request from: Richard Montgomery ok
|
ELE08-01683
| Temporary Service | 9/24/2008 | 9/24/2008 | 9/24/2008 2:57:38 PM | P | PART |
|
|
Contact Chris Carmine. Inspection of temporary power. Phone #: ###-#### Internet Inspection Request from: Shelli Daylong t/s from original t/s ok
|
ELE08-00026
| Electrical Rough-In | 9/24/2008 | 9/24/2008 | 9/24/2008 2:33:28 PM | P | PART |
|
|
kenneth - after 2 please Phone #: ###-#### see added p/s
|
ELE08-00026
| Permanent Service | 9/24/2008 | 9/24/2008 | 9/24/2008 2:33:10 PM | P | PASS |
|
|
kenneth - after 2 please Phone #: ###-#### p/s u/g new ok
|
ELE08-02400
| Final | 9/23/2008 | 9/24/2008 | 9/24/2008 1:40:47 PM | P | PASS |
|
|
this is ready Phone #: ###-#### Internet Inspection Request from: gary batten
|
ELE08-02167
| Electrical Rough-In | 9/24/2008 | 9/24/2008 | 9/24/2008 12:47:51 PM | P | PART |
|
|
Contact is Andy. Please inspect underslab electrical. Phone #: ###-#### Internet Inspection Request from: David Bonner all u/g inside of building ok
|
ELE08-02562
| Electrical Rough-In | 9/24/2008 | 9/24/2008 | 9/24/2008 12:14:42 PM | P | PART |
|
|
Scheduled by a contractor via Hello! on 9/24/2008 at 7:04:56 AM. Contact: ###-####. walls ok 3rd floor numbers 312, and 313
|
ELE08-02600
| Electrical Rough-In | 9/23/2008 | 9/24/2008 | 9/24/2008 11:05:52 AM | A | FAIL |
|
|
contact: Bob Schroder Phone #: ###-#### Internet Inspection Request from: Julie Schroder called corr210.52(B) din rm shall be on SABC, 250.52(A)(1) or 104(A)(1) grd or bond water too service not subpanel, 344.46 and 300.10&12 needs bushings for rigid nipple 4 locknuts, size wire to subpanel to T310.16 3 cu or 1 alum needs connectors for cables and seal unused KOs subpanel
|
ESC08-00720
| General Inspection | 9/24/2008 | 9/24/2008 | 9/24/2008 11:00:16 AM | A | PART |
|
|
site ok
|
ELE08-02602
| Electrical Rough-In | 9/23/2008 | 9/24/2008 | 9/24/2008 10:12:35 AM | A | PASS |
|
|
jay Phone #: ###-#### r/i ok
|
ESC08-00362
| General Inspection | 9/24/2008 | 9/24/2008 | 9/24/2008 10:07:53 AM | A | PART |
|
|
ok
|
ESC08-00816
| General Inspection | 9/24/2008 | 9/24/2008 | 9/24/2008 9:47:02 AM | A | PART |
|
|
ok front clean landscape work in back
|
ELE08-02590
| Conference | 9/22/2008 | 9/24/2008 | 9/24/2008 9:36:58 AM | A | DONE |
|
|
David Phone #: ###-#### went over NEC requirements for subpanel , kit. and din rm
|
ESC06-01785
| General Inspection | 9/24/2008 | 9/24/2008 | 9/24/2008 8:46:04 AM | A | PART |
|
|
ok
|
ELE08-01979
| Conference | 9/23/2008 | 9/24/2008 | 9/24/2008 8:43:07 AM | A | FAIL |
|
|
John- call 30 prior to going Phone #: ###-#### owner has already installed wiring , all messed up address kit circuits, din rm, range from sub panel. bed rm, and bath rm circuit 6" free length, outlet spacing in rooms and countertops, clearence for sub panel use only manufactures listed breakers, told owner he needs how too books and access to 2008 NEC
|
ELE08-02552
| Electrical Rough-In | 9/23/2008 | 9/24/2008 | 9/24/2008 8:07:55 AM | A | PART |
|
|
kevin - groundwork Phone #: ###-#### electrode ok for dirt ,, shall terminate all GEC and water bonds to neutral bus
|