Inspections for the day of: Wednesday, September 24, 2008.
Number of inspections: 18
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE07-00275 ELE-Aging Inspection9/24/20089/24/20089/25/2008 9:57:18 AM DONE
called, left message to return call
ELE08-02604 Electrical Rough-In9/24/20089/24/20089/25/2008 5:32:39 AMPFAIL
Please call James at ###-#### he will meet you there Phone #: ###-#### Internet Inspection Request from: Beka Hereau met contractor, left correction notice, BCC shall have permits on job, plans, BLD & Plumbing, contractor called after left and said he found bld, told to recall with all attached to electrical permit
ESC08-00433 General Inspection9/24/20089/24/20089/24/2008 4:05:06 PMAPART
looked ok
ESC07-01432 General Inspection9/24/20089/24/20089/24/2008 4:04:09 PMPPART
looked ok
ESC08-00457 General Inspection9/24/20089/24/20089/24/2008 4:02:29 PMAPART
looked ok
ELE08-02584 Conference9/24/20089/24/20089/24/2008 4:01:31 PMPDONE
Robert Phone #: ###-#### talked about work to be done where walls are opened up, nec requirements, outlet spacing, free conductor, where to get books on wiring, when to call for inspection, no esc this project
ELE08-02610 Final9/24/20089/24/20089/24/2008 2:55:33 PMPPASS
Phone #: ###-#### Internet Inspection Request from: John Edwards ok to final, no esc this project
ELE08-01960 Electrical Rough-In9/24/20089/24/20089/24/2008 1:57:21 PMPCANC
Temp occupancy for 5th and possibly 4th floor. Phone #: ###-#### Internet Inspection Request from: jesse busack wrong type request, see part final, no esc this project
ELE08-01960 Final9/24/20089/24/20089/24/2008 1:56:52 PMPPART
Temp occupancy for 5th and possibly 4th floor. Phone #: ###-#### Internet Inspection Request from: jesse busack part final for 5th floor to allow temp occupancy, initialed card, no esc this project
ELE08-02423 Electrical Rough-In9/23/20089/24/20089/24/2008 1:26:53 PMPPASS
JASON BLDG 3 L4 UNITS C2 & E1 Phone #: ###-#### Internet Inspection Request from: Sean DeLacy ric 2 units 4th floor anop
ELE08-02545 Rough-In Permanent Service9/23/20089/24/20089/24/2008 12:49:10 PMPCANC
This is ready, electrician is Aaron at ###-#### Phone #: ###-#### Internet Inspection Request from: gary batten called, left message, wrong type request, people don't know anything about job if here or at ramp, said to recall
ELE08-01957 Final9/24/20089/24/20089/24/2008 12:25:42 PMPPASS
Phone #: ###-#### Internet Inspection Request from: steve creswell corrections made, ok to final
ELE08-02559 Conference9/23/20089/24/20089/24/2008 11:36:30 AMADONE
Scheduled by a contractor via Hello! on 9/23/2008 at 2:16:23 PM. Contact: ###-####. talked about remodel for hangar, about paint booths, service, distribution, no violations to remain, listing for booths, area classification
ELE08-02250 Conference9/23/20089/24/20089/24/2008 10:49:27 AMADONE
DAVE Phone #: ###-#### Internet Inspection Request from: Sean DeLacy met contractor, ok to saw-cut floor and provide depressed floor and to move false ceiling to allow gear to fit without going in between floor joists, they will either put in small sump pump or curbing in floor, no esc this project
ELE08-01957 Final9/23/20089/24/20089/24/2008 10:00:09 AMAFAIL
the door should be open by 8:30. I will be there by 9:00 Phone #: ###-#### Internet Inspection Request from: steve creswell met contractor, left correction notice, NEC 410.16 edge of fixture shall be 12" from edge of storage space- both units, 406.4 receptacle shall be securely mounted-washer shoshone side, 110.22 shall label all disconnects- furnaces, service, 406.5 receptacle faceplate shall completely cover opening west microwave, 344.30 shall strap rmc at riser-service
ELE08-02536 Electrical Rough-In9/23/20089/24/20089/24/2008 9:04:11 AMAPART
Requesting a partial underground inspection. Phone #: ###-#### Internet Inspection Request from: Dan Hardisty ok to cover stem walls east of transformer, ok to cover u/g duct north of transformer to elect room about 120 feet north, looked at block-outs east stem walls
ELE08-02592 Temporary Service9/23/20089/24/20089/24/2008 8:33:42 AMAPASS
Requesting an inspection of the temporary power. Phone #: ###-#### Internet Inspection Request from: Dan Hardisty t/s u/g n ok, no esc this project
ELE08-02603 Temporary Service9/23/20089/24/20089/24/2008 8:23:50 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson t/s u/g n ok, no esc this project