ELE12-00654
| ELE-Aging Inspection | 9/24/2014 | 9/24/2014 | 9/30/2014 4:40:53 AM | | CANC |
|
|
|
ELE14-01901
| Final | 9/24/2014 | 9/24/2014 | 9/24/2014 2:17:53 PM | P | PASS |
|
|
GARAGE CODE 4224 Phone #: ###-#### Inspection requested via web by Bob Glenn ok final
|
ELE14-02656
| Rough-In Permanent Service | 9/24/2014 | 9/24/2014 | 9/24/2014 1:50:56 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI ri ok, p/s u/g n ok
|
ELE14-01993
| Electrical Rough-In | 9/24/2014 | 9/24/2014 | 9/24/2014 1:18:04 PM | P | PASS |
|
|
Please call Clay when you are on your way. Thank You. Phone #: ###-#### Inspection requested via web by Clay Morgan ri ok
|
ELE14-02654
| Temporary Service | 9/23/2014 | 9/24/2014 | 9/24/2014 12:58:34 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Mike Cole called, no job id sticker, no address, no esc sign, fee due
|
ELE14-02574
| Electrical Rough-In | 9/24/2014 | 9/24/2014 | 9/24/2014 12:21:45 PM | P | PASS |
|
|
Mike-please call for access Phone #: ###-#### ri ok lower part only
|
ELE14-02363
| Permanent Service | 9/23/2014 | 9/24/2014 | 9/24/2014 11:34:47 AM | A | FAIL |
|
|
The access code is 6210, any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren called, left message, ground rods not installed, access code not working
|
ELE14-01932
| Final | 9/23/2014 | 9/24/2014 | 9/24/2014 11:05:26 AM | A | FAIL |
|
|
Key is on top of meter main for access. Thank you Phone #: ###-#### Inspection requested via web by daniel bibikov called, NEC 210.52(E) shall provide rear receptacle
|
ELE14-01973
| Final | 9/23/2014 | 9/24/2014 | 9/24/2014 11:01:34 AM | A | FAIL |
|
|
Key is on top of meter main back of the house for access. Thank you Phone #: ###-#### Inspection requested via web by daniel bibikov called, left correction notice, NEC 110 shall install devices per instructions, 4-way switches top stairs, hall, pantry gfci shall operate, shall protect grounding electrode conductor
|
ELE14-01934
| Electrical Rough-In | 9/23/2014 | 9/24/2014 | 9/24/2014 9:47:50 AM | A | FAIL |
|
|
Underground inspection for feed from transformer to building. Contact is Jay Sprik. Phone #: ###-#### Inspection requested via web by Richard Montgomery called, told to check with ipco, top of raceway only 24" below driveway, told that city usually not responsible for utility side of service
|
ELE14-02082
| Electrical Rough-In | 9/23/2014 | 9/24/2014 | 9/24/2014 9:32:41 AM | A | PASS |
|
|
Mike Phone #: ###-#### u/g ok south parking lot lighting
|
ELE14-01595
| Electrical Rough-In | 9/23/2014 | 9/24/2014 | 9/24/2014 9:12:39 AM | A | PART |
|
|
Contact: Wes Powell.. underground inspection please Phone #: ###-#### Inspection requested via web by Deb Gooden south of bldg, west 1/2 u/g for lighting ok cover, talked about generator wiring from u/g
|
ELE14-02656
| Rough-In Permanent Service | 9/23/2014 | 9/24/2014 | 9/24/2014 8:29:33 AM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by TOM BICANDI called, left correction notice, NEC 334.80 shall derate conductors over panel if more than 2 nm cables in hole, 334.23 shall protect nm cable within 6' of attic accesses, 210.52 shall install receptacle or floor box in 2' wall by pocket door, 300.4(A) edge of bored hole shall be 1 1/4" from face of framing member or add steel plate, BCC shall install wire into fan box
|