Inspections for the day of: Thursday, September 25, 2003.
Number of inspections: 14
Percentage of inspections complete: 93 %
Percentage of inspections not complete: 7 %
Contact Information
InspectorJim Johnson
TitlePLM-INSPECTOR
Phone #794-9476
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
PLM03-00088 Final9/18/20039/18/2003 P 
Scheduled by a contractor via Hello! on 9/18/2003 at 9:44:39 AM. Contact: ###-####.
PLM03-00418 PLM-Aging Inspection9/25/20039/25/20039/25/2003 12:00:00 AM PASS
work still in progress 9/25/2003 8:08:53 AM
PLM03-02657 Final9/24/20039/25/20039/25/2003 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 9/24/2003 at 8:23:17 AM. Contact: ###-####.
PLM03-02989 Plumbing Rough-in9/24/20039/25/20039/25/2003 12:00:00 AMAPASS
Scheduled by a contractor via Hello! on 9/24/2003 at 10:28:22 AM. Contact: ###-####.
PLM03-02992 Water and/or Sewer9/24/20039/25/20039/25/2003 12:00:00 AMAPASS
###-#### dj
PLM03-02430 Plumbing Rough-in9/24/20039/25/20039/25/2003 12:00:00 AMAFAIL
shawn; Phone #: ###-#### Internet Inspection Request from: Darla Downs need to pipe ejector discharge line to 4 inch drain need to pipe 1 inch water up through water heater to first bathroom for water distribution on hot side told plumber on job site wiil recall when ready 9/25/2003 9:14:53 AM
PLM03-02853 Final9/25/20039/25/20039/25/2003 12:00:00 AMAPASS
this just needs finaled...thanks darla
PLM03-02356 Water and/or Sewer9/25/20039/25/20039/25/2003 12:00:00 AMPPART
shelley; Phone #: ###-#### Internet Inspection Request from: Darla Downs provide end of line cleanout on 3 inch drain need to support drain every 4 feet home owner to recall when ready 9/25/2003 1:24:28 PM
PLM03-02986 Water and/or Sewer9/25/20039/25/20039/25/2003 12:00:00 AMPFAIL
rob -###-#### need to increase water line to 1-1/4 also need to correct reverse grade in sewer line from 22 closest to street out to stub called rob with hardrock will recall when ready 9/25/2003 3:21:58 PM
PLM03-02998 Plumbing Rough-in9/24/20039/25/20039/25/2003 12:00:00 AMPPART
ron; Phone #: ###-#### Internet Inspection Request from: Darla Downs trunk lines in area c and d test ok 9/25/2003 3:58:42 PM
PLM03-02963 Water and/or Sewer9/25/20039/25/20039/25/2003 12:00:00 AMPPASS
nathan; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
PLM03-02964 Water and/or Sewer9/25/20039/25/20039/25/2003 12:00:00 AMPPASS
nathan; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
PLM03-02999 Water and/or Sewer9/25/20039/25/20039/25/2003 12:00:00 AMPPASS
danny; Phone #: ###-#### Internet Inspection Request from: Darla Downs
PLM03-03001 Sprinkler (Final)9/25/20039/25/20039/25/2003 12:00:00 AMPPASS
###-#### craig