BLD02-00090
| FIRE-Final Inspection | 9/24/2003 | 9/25/2003 | 9/25/2003 12:00:00 AM | A | FAIL |
|
|
john ; Phone #: ###-#### Internet Inspection Request from: Annette Moore started testing the alarms; see FIR03-00104 for info 9/25/2003 12:23:43 PM
|
BLD03-00866
| FIRE-Final Inspection | 9/24/2003 | 9/25/2003 | 9/25/2003 12:00:00 AM | A | PASS |
|
|
dirk; Phone #: ###-#### Internet Inspection Request from: Barbara Moore
|
BLD03-01618
| FIRE-Final Inspection | 9/25/2003 | 9/25/2003 | 9/25/2003 12:00:00 AM | A | PASS |
|
|
|
BLD03-01382
| FIRE-Final Inspection | 9/25/2003 | 9/25/2003 | 9/25/2003 12:00:00 AM | P | PASS |
|
|
|
BLD03-01618
| FIRE-Final Inspection | 9/25/2003 | 9/25/2003 | 9/25/2003 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 9/25/2003 at 8:39:21 AM. Contact: ###-####.
|
BLD03-01060
| FIRE-Final Inspection | 9/25/2003 | 9/25/2003 | 9/25/2003 12:00:00 AM | P | FAIL |
|
|
larry; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie penetrations reuire fire stopping; duct opening in corridor wall requires smoke/fire damper with detection to operate damper; hang fire extinguisher 9/25/2003 4:06:41 PM
|
FIR03-00545
| INSP-Final Inspection | 9/25/2003 | 9/25/2003 | 9/25/2003 12:00:00 AM | P | PASS |
|
|
|
FIR03-00104
| INSP-Final Inspection | 9/25/2003 | 9/25/2003 | 9/25/2003 12:00:00 AM | P | FAIL |
|
|
started testing alarms - detectors within 3 ft of diffusers; fire pump controller not reporting phase reversal and showed pump running when pump wasn't running; phone line not reporting trouble; need special function buttons labeled; batteries not reporing troubles; will need to test devices and all exsisting sprinkler valves; need maps; will continue testing on 9/26 9/25/2003 4:13:57 PM
|
BLD02-02823
| FIRE-Final Inspection | 9/25/2003 | 9/25/2003 | 9/25/2003 12:00:00 AM | P | PART |
|
|
per approval from Dave Miller a temp occupancy is approved for fire/life safety pending approval of fire alarm plans 9/25/2003 4:09:15 PM
|
FIR03-00515
| INSP-Final Inspection | 9/24/2003 | 9/25/2003 | 9/25/2003 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 9/24/2003 at 5:24:11 PM. Contact: ###-####.
|
FIR03-00412
| INSP-Conference | 9/24/2003 | 9/25/2003 | 9/25/2003 12:00:00 AM | P | CANC |
|
|
ernie; Phone #: ###-#### Internet Inspection Request from: Barbara Moore resacheduled for 9/26 9/25/2003 11:02:14 AM
|
FIR03-00068
| INSP-Alarm Testing | 9/23/2003 | 9/25/2003 | 9/25/2003 12:00:00 AM | P | PART |
|
|
Scheduled by a contractor via Hello! on 9/23/2003 at 1:58:24 PM. Contact: ###-####. tested fire pump with pump rep and Shilo - tested per NFPA 20 9/25/2003 4:10:25 PM
|