Inspections for the day of: Thursday, September 25, 2008.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE08-02545 Electrical Rough-In9/24/20089/25/20089/25/2008 3:45:52 PMPPASS
work is in ramp area, ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten ric ok, no esc this project
ELE08-02545 Final9/25/20089/25/20089/25/2008 3:33:02 PMPPASS
work is in ramp area, ready for inspection Phone #: ###-#### Internet Inspection Request from: gary batten ok to final, no esc this project
ESC07-01499 General Inspection9/25/20089/25/20089/25/2008 3:09:43 PMPPART
looked ok
ESC08-00490 General Inspection9/25/20089/25/20089/25/2008 3:04:27 PMPPART
looked ok
ELE08-02616 Final9/25/20089/25/20089/25/2008 3:03:22 PMPPASS
Phone #: ###-#### Internet Inspection Request from: PAT MILLER ok to final, no esc this project
ELE07-02961 Electrical Rough-In9/25/20089/25/20089/25/2008 2:27:06 PMPPART
john Phone #: ###-#### corrections made, ok to cover dining room only, owner made layout, signed plan also, no esc this project
ELE08-01191 Final9/25/20089/25/20089/25/2008 1:45:28 PMPFAIL
Bill Entry code 19690 Phone #: ###-#### Internet Inspection Request from: Alan Lusk called, left correction notice, NEC 352.30 shall strap rnc within 3' of conduit termination, 408.4 shall provide circuit directoru at outside panel, 210.52)C)(3),(4), shall provide receptacle at end of peninsula separated by cook-top, 422.31(B) shall provide dishwasher lock-out, 110.3(B) shall provide listing for jetted tub and proper access hole per manufacturers instructions
ELE08-02208 Electrical Rough-In9/25/20089/25/20089/25/2008 12:51:54 PMPPASS
dale - uffer Phone #: ###-#### concrete encased electrode ok to pour
ELE08-02621 Rough-In Permanent Service9/25/20089/25/20089/25/2008 12:17:06 PMPCANC
george Phone #: ###-#### see conference
ELE08-02621 Conference9/25/20089/25/20089/25/2008 12:16:53 PMPDONE
george Phone #: ###-#### told electrician that center of breaker handle shall not be over 6'7" above floor, explained that ri must be ready before inspection- garage area, no esc this project
ESC08-00306 General Inspection9/25/20089/25/20089/25/2008 9:33:16 AMAPART
looked ok
ELE08-01089 Electrical Rough-In9/24/20089/25/20089/25/2008 8:54:31 AMACANC
groundwork Phone #: ###-#### Internet Inspection Request from: Alan Lusk wrong address, wrong permit, told to call other inspector
ESC08-00512 General Inspection9/25/20089/25/20089/25/2008 8:17:54 AMAPART
looks ok
ELE08-02120 Electrical Rough-In9/24/20089/25/20089/25/2008 8:17:02 AMAPASS
Ceiling Inspection. Chris is the onsite contact, his number is ###-####. Thank You. Phone #: ###-#### Internet Inspection Request from: Shawna Gates ok to cover hardlids baths only 1 and 2 floor anop