ESC07-00871
| Aging Inspection | 9/25/2009 | 9/25/2009 | 9/28/2009 9:29:55 AM | | CANC |
|
|
|
ELE09-01152
| Electrical Rough-In | 9/25/2009 | 9/25/2009 | 9/25/2009 3:09:03 PM | P | PASS |
|
|
underground for pole lights Phone #: ###-#### Internet Inspection Request from: Ron Zimmerman ok
|
ELE09-00783
| Electrical Rough-In | 9/25/2009 | 9/25/2009 | 9/25/2009 3:08:43 PM | P | PASS |
|
|
Danny-ceiling inspection please Phone #: ###-#### mens rest rm and deli ceilings ok
|
ELE09-01827
| Electrical Rough-In | 9/25/2009 | 9/25/2009 | 9/25/2009 2:23:38 PM | P | PASS |
|
|
troy Phone #: ###-#### ok
|
ELE09-01831
| Electrical Rough-In | 9/25/2009 | 9/25/2009 | 9/25/2009 1:46:34 PM | P | PASS |
|
|
Jimmy Phone #: ###-####ok
|
ELE09-01594
| Electrical Rough-In | 9/25/2009 | 9/25/2009 | 9/25/2009 1:29:45 PM | P | PASS |
|
|
Electrician on site - Gene. Please do Common area and gear rough-in only. Thank you! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson see added r/i p/s
|
ELE09-01594
| Rough-In Permanent Service | 9/25/2009 | 9/25/2009 | 9/25/2009 1:29:15 PM | P | PASS |
|
|
Electrician on site - Gene. Please do Common area and gear rough-in only. Thank you! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson r/i all common areas ok p/s u/g new ok
|
ELE09-01830
| Permanent Service | 9/25/2009 | 9/25/2009 | 9/25/2009 12:23:05 PM | P | PASS |
|
|
Tom Phone #: ###-#### p/s u/g rec. ok
|
ELE09-01830
| Final | 9/25/2009 | 9/25/2009 | 9/25/2009 12:21:50 PM | P | PASS |
|
|
Tom Phone #: ###-#### ok
|
ELE09-01210
| Final | 9/24/2009 | 9/25/2009 | 9/25/2009 11:44:25 AM | A | PASS |
|
|
Please provide final inspection. Phone #: ###-#### Internet Inspection Request from: Spencer Mclean ok card signed
|
ELE09-01207
| Final | 9/24/2009 | 9/25/2009 | 9/25/2009 11:44:06 AM | A | PASS |
|
|
Please provide final inspection. Phone #: ###-#### Internet Inspection Request from: Spencer Mclean ok card signed
|
ELE09-01337
| Final | 9/24/2009 | 9/25/2009 | 9/25/2009 10:39:00 AM | A | PASS |
|
|
Front door will be open. Phone #: ###-#### Internet Inspection Request from: Joe Thomas
|
ELE07-02961
| Electrical Rough-In | 9/24/2009 | 9/25/2009 | 9/25/2009 10:04:24 AM | A | FAIL |
|
|
john Phone #: ###-#### met owner corr. 410.2&16 clearence for closet fixtures, 210.52(A) outlet spacing, fixed panel of sider, recepts not allowed above baseboard heaters, 210.52(F)&210.11(C)(2)all recept outlets in laundry rm shall be 20 amp laundry circuit, 314,16 box fill everywhere 314.43 screws not alled in non-metallic boxes, 300.14 shall provide 6" free length conductor note some of the violations posted are the same ones noted on prior inspection back in 2008
|
ELE09-01556
| Final | 9/24/2009 | 9/25/2009 | 9/25/2009 9:56:08 AM | A | PASS |
|
|
Please call Jeff Creek at ####-#### w/ 1/2 notice for access. Thanks, Andrea. Phone #: ###-#### x0000 Internet Inspection Request from: Andrea Creek survey needs gfci for recepts within 6ft of laundry sink, talked with ele contr he will correct
|
ELE09-01824
| Final | 9/24/2009 | 9/25/2009 | 9/25/2009 8:34:13 AM | A | FAIL |
|
|
call Stan for access ###-#### Phone #: ###-#### Internet Inspection Request from: Bruce Herold corr called clean t/s 110.12(B) 110.3(B) feeder to job trailer shall be sized to trailer nameplate, T400.5(A) size co cord for amps, provide access to site, call for a t/s inspection 110.9&10 gear shall be rated for fault and short circuit currentwhen next to xformer
|