ELE12-00654
| ELE-Aging Inspection | 9/25/2013 | 9/25/2013 | 9/27/2013 4:52:30 PM | | DONE |
|
|
Still under construction
|
ELE12-00663
| ELE-Aging Inspection | 9/25/2013 | 9/25/2013 | 9/27/2013 4:50:06 PM | | DONE |
|
|
Waiting on owner
|
ELE13-02621
| Electrical Rough-In | 9/25/2013 | 9/25/2013 | 9/25/2013 4:35:38 PM | P | PASS |
|
|
Tom Phone #: ###-#### 3rd floor wall Rough in ok cover
|
ELE13-02620
| Electrical Rough-In | 9/25/2013 | 9/25/2013 | 9/25/2013 4:34:55 PM | P | PASS |
|
|
4th floor cove lights in front elevator rough in ok cover.
|
ELE12-01710
| Electrical Rough-In | 9/25/2013 | 9/25/2013 | 9/25/2013 3:51:42 PM | P | NH |
|
|
Contact: Wes Powell Phone #: ###-#### >> Inspection requested via web by Deb Gooden Contractor had left for day will reschedule
|
ELE13-01984
| Final | 9/24/2013 | 9/25/2013 | 9/25/2013 3:30:24 PM | P | PASS |
|
|
Home Owners and the General Contractor will be there. Phone #: ###-#### >> Inspection requested via web by Neal Rumsey Final ok
|
ELE13-01984
| Electrical Rough-In | 9/25/2013 | 9/25/2013 | 9/25/2013 3:30:02 PM | P | PASS |
|
|
Home Owners and the General Contractor will be there. Phone #: ###-#### >> Inspection requested via web by Neal Rumsey Condencing unit for wine room rough in ok
|
ELE13-01829
| Electrical Rough-In | 9/23/2013 | 9/25/2013 | 9/25/2013 3:04:13 PM | P | PASS |
|
|
anthony Phone #: ###-#### Rough in ok cover
|
ELE13-01829
| Permanent Service | 9/25/2013 | 9/25/2013 | 9/25/2013 3:03:29 PM | P | PASS |
|
|
anthony Phone #: ###-#### p/s u/g n ok
|
ELE13-02643
| Rough-In Permanent Service | 9/23/2013 | 9/25/2013 | 9/25/2013 2:43:35 PM | A | FAIL |
|
|
George Phone #: ###-#### >> Inspection requested via web by George Pascua 310.15 (B)(6)- Table 310.15(B)(6) does not apply in this case for 2 reasons. 1- Cable used to feed panel shall serve 100% of dwellings diversified load. 2. 60 degree columb shall be used because SER cable will be buried i insulation and will not be able to disapate heat. 300.4- SER cable shall be protected from physical damage where it passes through bored hole ablve panel.
|
ELE13-02651
| Temporary Service | 9/24/2013 | 9/25/2013 | 9/25/2013 1:58:33 PM | A | PASS |
|
|
Temp power pole inspection for the Jacksons rebuild. Contact is Jay Sprik. Phone #: ###-#### >> Inspection requested via web by Richard Montgomery t/s o/h n ok
|
MIS13-00277
| ELE-Conference | 9/25/2013 | 9/25/2013 | 9/25/2013 1:41:05 PM | P | DONE |
|
|
working with out a permit Contacted home owner about work that is visible on exterior of home. assessed double fee and posted correction notice.
|
ELE13-00390
| Final | 9/24/2013 | 9/25/2013 | 9/25/2013 1:39:34 PM | A | CANC |
|
|
Paula ###-#### for access /please call before going out Home owner called for final inspection with having another contractor finish minimal work on home. She has been instructed to have 2 nd contractor pull a permit with work performed listed in detail.
|
ELE13-02656
| Electrical Rough-In | 9/24/2013 | 9/25/2013 | 9/25/2013 1:18:24 PM | P | PASS |
|
|
pool PMX ###-#### Tub bonding and under ground rough in ok cover.
|
ELE13-01683
| Rough-In Permanent Service | 9/24/2013 | 9/25/2013 | 9/25/2013 12:47:03 PM | A | FAIL |
|
|
call before to make sure he is there // Kevin (alt number ###-####) Phone #: ###-#### 334.30- NM cable shall be supported so not to damage cable at inervals not exceeding 4 1/2'. 334.30 (A)- NM cable shall be secured with in 12" of box with clamp or 8" with out. 300.4 Where subject to physical damage NM cable shall be protected when ran through bored or notched studs when hole is less than 1 1/4" from stud surface. 300.4- Abrasion protection shall be provided where NM cable enters metal boxes.
|
ELE13-02295
| Final | 9/25/2013 | 9/25/2013 | 9/25/2013 10:34:11 AM | P | PASS |
|
|
Contact: Clayton Pennington Phone #: ###-#### >> Inspection requested via web by Deb Gooden Final ok
|
ELE13-01291
| Electrical Rough-In | 9/24/2013 | 9/25/2013 | 9/25/2013 10:32:56 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Tony Keen Ramp pour as noted on print rough in ok cover
|
ELE13-02242
| Final | 9/25/2013 | 9/25/2013 | 9/25/2013 10:09:20 AM | A | PASS |
|
|
Cell ###-#### Phone #: ###-#### >> Inspection requested via web by Mark M No card posted final ok
|
ELE13-02295
| Final | 9/24/2013 | 9/25/2013 | 9/25/2013 9:50:24 AM | A | PASS |
|
|
Final inspection please. Contact name Clayton Pennington. Thank you. Phone #: ###-#### >> Inspection requested via web by Deb Gooden Final ok
|
ELE13-02263
| Final | 9/24/2013 | 9/25/2013 | 9/25/2013 9:18:42 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Dan Rohl No card posted, furnature moved in. Final ok
|
ELE13-02153
| Electrical Rough-In | 9/24/2013 | 9/25/2013 | 9/25/2013 9:14:10 AM | A | PASS |
|
|
Rough-in inspection for Suite 184, off-site of Bodovino. Contact on-site is Rod Tomlinson ###-####. Please call with any questions. Phone #: ###-#### >> Inspection requested via web by Clint Tate Wall and hard lid rough in ok cover
|