ELE13-01178
| ELE-Aging Inspection | 9/25/2015 | 9/25/2015 | 9/30/2015 2:36:08 PM | | DONE |
|
|
Drove by and inspected
|
ELE13-01178
| Final | 9/25/2015 | 9/25/2015 | 9/25/2015 3:47:02 PM | P | PASS |
|
|
Final ok
|
ELE15-03054
| Rough-In Permanent Service | 9/23/2015 | 9/25/2015 | 9/25/2015 2:37:30 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan Lusk Rough in ok cover p/s u/g n ok
|
ELE15-02961
| Final | 9/25/2015 | 9/25/2015 | 9/25/2015 1:52:02 PM | P | PASS |
|
|
Please call half hour before inspection. Phone #: ###-#### Inspection requested via web by Stuart Welton Final ok
|
ELE15-03041
| Electrical Rough-In | 9/25/2015 | 9/25/2015 | 9/25/2015 1:39:12 PM | P | PASS |
|
|
Scott. Wall cover inspection seating area outside of pharmacy. Phone #: ###-#### Inspection requested via web by Sean DeLacy Wall rough in ok cover
|
ELE15-03071
| Electrical Rough-In | 9/24/2015 | 9/25/2015 | 9/25/2015 1:26:28 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Andrea Creek Addition to back of garage rough in ok cover
|
ELE15-02968
| Electrical Rough-In | 9/25/2015 | 9/25/2015 | 9/25/2015 12:56:53 PM | P | PASS |
|
|
We are requesting an underground inspection for today 9/25/15 in the afternoon. Our contact is Todd ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate Relocating and adding floor receptacles. Under slab rough in ok cover
|
ELE15-03084
| Temporary Service | 9/25/2015 | 9/25/2015 | 9/25/2015 12:15:06 PM | P | PASS |
|
|
Larry Phone #: ###-#### t/s u/g n ok
|
ELE12-01916
| ELE-Aging Inspection | 9/25/2015 | 9/25/2015 | 9/25/2015 11:12:48 AM | | CANC |
|
|
Too busy
|
ELE13-01644
| ELE-Aging Inspection | 9/25/2015 | 9/25/2015 | 9/25/2015 11:12:28 AM | | CANC |
|
|
Too busy
|
ELE13-00434
| ELE-Aging Inspection | 9/25/2015 | 9/25/2015 | 9/25/2015 11:12:13 AM | | CANC |
|
|
Too busy
|
ELE15-03069
| Conference | 9/24/2015 | 9/25/2015 | 9/25/2015 11:09:32 AM | A | DONE |
|
|
Adam Phone #: ###-####-Adam is at work please call with a meet time Home owner to call and change name on homeowner permit to his own. Discussed the installation of to can lights to front entry way. IC rating, nail plates, and securing NM cable.
|
ELE15-03064
| Final | 9/24/2015 | 9/25/2015 | 9/25/2015 10:33:18 AM | A | PASS |
|
|
Circuits 40 and 42 are the new ones. Thank you! Phone #: ###-#### Inspection requested via web by Dan Mitchell Final ok
|
ELE15-03064
| Electrical Rough-In | 9/24/2015 | 9/25/2015 | 9/25/2015 10:32:44 AM | A | PASS |
|
|
Circuits 40 and 42 are the new ones. Thank you! Phone #: ###-#### Inspection requested via web by Dan Mitchell Rough in ok.
|
ELE15-03000
| Rough-In Permanent Service | 9/25/2015 | 9/25/2015 | 9/25/2015 10:31:04 AM | P | PASS |
|
|
Rough in ok cover p/s u/g n ok
|
ELE15-01138
| Electrical Rough-In | 9/24/2015 | 9/25/2015 | 9/25/2015 10:00:05 AM | A | CANC |
|
|
We are requesting a temp. occupancy inspection for tomorrow 9/25/15 in the AM. Our onsite contact is Bryant @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate OK to occupy soil holding rms, bathroom, exam areas not ready yet. Temp final ok
|
ELE15-03068
| Permanent Service | 9/24/2015 | 9/25/2015 | 9/25/2015 9:32:12 AM | A | FAIL |
|
|
The access code is 6214, any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren BCC 4-05-32- Code violations not to be retained. 250.104- Metal water piping system shall be bonded back to service. Jump cold to hot at water heater. 334.15(B)- NM cable shall not be installed where subject to physical damage. Kitchen cabinet setting on counter. 408.4- Circuit directory shall be complete.
|
ELE15-03030
| Temporary Service | 9/25/2015 | 9/25/2015 | 9/25/2015 9:00:56 AM | A | PASS |
|
|
call dene with any questions thank you Phone #: ###-#### Inspection requested via web by kim grundhauser t/s u/g n ok
|
ELE15-02303
| Conference | 9/24/2015 | 9/25/2015 | 9/24/2015 1:43:47 PM | A | DONE |
|
|
Ready now Inspection requested via web by mike brown Discussed with contractor if receptacle outlets would be code required for counter top space behind kitchen sink. Counter top area behind sink is to be greater than 12" creating useable counter space. 2 receptacle outlets minimum behind sink required as per 210.52(C)(1)
|