Inspections for the day of: Friday, September 25, 2015.
Number of inspections: 19
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorRock A. Hudson
TitleELE-INSPECTOR
Phone #794-6794
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE13-01178 ELE-Aging Inspection9/25/20159/25/20159/30/2015 2:36:08 PM DONE
Drove by and inspected
ELE13-01178 Final9/25/20159/25/20159/25/2015 3:47:02 PMPPASS
Final ok
ELE15-03054 Rough-In Permanent Service9/23/20159/25/20159/25/2015 2:37:30 PMPPASS
Phone #: ###-#### Inspection requested via web by Alan Lusk Rough in ok cover p/s u/g n ok
ELE15-02961 Final9/25/20159/25/20159/25/2015 1:52:02 PMPPASS
Please call half hour before inspection. Phone #: ###-#### Inspection requested via web by Stuart Welton Final ok
ELE15-03041 Electrical Rough-In9/25/20159/25/20159/25/2015 1:39:12 PMPPASS
Scott. Wall cover inspection seating area outside of pharmacy. Phone #: ###-#### Inspection requested via web by Sean DeLacy Wall rough in ok cover
ELE15-03071 Electrical Rough-In9/24/20159/25/20159/25/2015 1:26:28 PMPPASS
Phone #: ###-#### Inspection requested via web by Andrea Creek Addition to back of garage rough in ok cover
ELE15-02968 Electrical Rough-In9/25/20159/25/20159/25/2015 12:56:53 PMPPASS
We are requesting an underground inspection for today 9/25/15 in the afternoon. Our contact is Todd ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate Relocating and adding floor receptacles. Under slab rough in ok cover
ELE15-03084 Temporary Service9/25/20159/25/20159/25/2015 12:15:06 PMPPASS
Larry Phone #: ###-#### t/s u/g n ok
ELE12-01916 ELE-Aging Inspection9/25/20159/25/20159/25/2015 11:12:48 AM CANC
Too busy
ELE13-01644 ELE-Aging Inspection9/25/20159/25/20159/25/2015 11:12:28 AM CANC
Too busy
ELE13-00434 ELE-Aging Inspection9/25/20159/25/20159/25/2015 11:12:13 AM CANC
Too busy
ELE15-03069 Conference9/24/20159/25/20159/25/2015 11:09:32 AMADONE
Adam Phone #: ###-####-Adam is at work please call with a meet time Home owner to call and change name on homeowner permit to his own. Discussed the installation of to can lights to front entry way. IC rating, nail plates, and securing NM cable.
ELE15-03064 Final9/24/20159/25/20159/25/2015 10:33:18 AMAPASS
Circuits 40 and 42 are the new ones. Thank you! Phone #: ###-#### Inspection requested via web by Dan Mitchell Final ok
ELE15-03064 Electrical Rough-In9/24/20159/25/20159/25/2015 10:32:44 AMAPASS
Circuits 40 and 42 are the new ones. Thank you! Phone #: ###-#### Inspection requested via web by Dan Mitchell Rough in ok.
ELE15-03000 Rough-In Permanent Service9/25/20159/25/20159/25/2015 10:31:04 AMPPASS
Rough in ok cover p/s u/g n ok
ELE15-01138 Electrical Rough-In9/24/20159/25/20159/25/2015 10:00:05 AMACANC
We are requesting a temp. occupancy inspection for tomorrow 9/25/15 in the AM. Our onsite contact is Bryant @ ###-####. Thank you. Phone #: ###-#### Inspection requested via web by Clint Tate
OK to occupy soil holding rms, bathroom, exam areas not ready yet. Temp final ok
ELE15-03068 Permanent Service9/24/20159/25/20159/25/2015 9:32:12 AMAFAIL
The access code is 6214, any questions please let me know, thx, TW. Phone #: ###-#### Inspection requested via web by Stephen Kren BCC 4-05-32- Code violations not to be retained.
250.104- Metal water piping system shall be bonded back to service. Jump cold to hot at water heater.
334.15(B)- NM cable shall not be installed where subject to physical damage. Kitchen cabinet setting on counter.
408.4- Circuit directory shall be complete.
ELE15-03030 Temporary Service9/25/20159/25/20159/25/2015 9:00:56 AMAPASS
call dene with any questions
thank you Phone #: ###-#### Inspection requested via web by kim grundhauser t/s u/g n ok
ELE15-02303 Conference9/24/20159/25/20159/24/2015 1:43:47 PMADONE
Ready now Inspection requested via web by mike brown Discussed with contractor if receptacle outlets would be code required for counter top space behind kitchen sink. Counter top area behind sink is to be greater than 12" creating useable counter space. 2 receptacle outlets minimum behind sink required as per 210.52(C)(1)