Inspections for the day of: Monday, September 25, 2017.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorMark Moncarr
TitleELE-INSPECTOR
Phone #685-9023
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE17-03145 Electrical Rough-In9/25/20179/25/20179/25/2017 2:31:01 PMPPASS
Phone #: ###-#### Inspection requested via web by Brian McCullough Ok cover
ELE17-03002 Final9/21/20179/25/20179/25/2017 2:01:31 PMACANC
Solar Array System Final Inspection Phone #: ###-#### Inspection requested via web by Paula Gietzen Amps and volts on disconnect needs filled out.
ELE17-03194 Final9/22/20179/25/20179/25/2017 1:58:44 PMPPASS
Please call when on way ###-#### Phone #: ###-#### Inspection requested via web by Randy Fletcher Ok cover.
ELE17-02677 Final9/25/20179/25/20179/25/2017 1:43:19 PMPPASS
Call Barry if any questions Phone #: ###-#### Inspection requested via web by Christian Kilpatrick Ok final
ELE17-03019 Electrical Rough-In9/25/20179/25/20179/25/2017 1:27:17 PMPPASS
Please take note that Idaho Power will be doing an underground Service and the trench will be dug sometime this week to install the PVC. The Sub-Panel upstairs is Hot and has the new Branch Circuit there, however, not landed due to waiting for Idaho Power to kill power on old panel and inspection for New Service. We need an inspection for the new panel as well to have power swung when Idaho power has completed the underground service at which time I will install the Expansion joint and Schedule 80 riser. Phone #: ###-#### Inspection requested via web by Anastacio Fuentes Ok cover except for panel location. Panel needs moved from over stairs.
ELE17-03019 Permanent Service9/25/20179/25/20179/25/2017 1:26:26 PMPPASS
p/s u/g n ok. Eliminating o/h service to underground.
ELE17-03196 Conference9/22/20179/25/20179/25/2017 12:31:40 PMADONE
Phone #: ###-#### Inspection requested via web by Don Conley Talked about relocation of service. Small porch addition was added which makes the o/h mast more than 4ft back from the facia. Also split buss panel will have a few circuits added too it. Split buss panels are no longer a listed item. Once circuits are added, panel needs to be replaced due to load capabilities.
ELE17-03147 Final9/20/20179/25/20179/25/2017 12:22:04 PMPPASS
Please call 30 minutes prior. Phone #: ###-#### Inspection requested via web by Mitch Whited Ok final. See notes about vandalized meter on permanent service inspection.
ELE17-03147 Permanent Service9/25/20179/25/20179/25/2017 12:21:16 PMAPASS
p/s o/h rec ok. Talked to the landlord about damage done to meter at apt. #312 1/2. Current tenant has invited a guest in that apparently caused damage to 2 meters on 2 seperate occasions. The first meter was not able to be found by IDP. Power to that unit has been off for a few weeks. Apparently said individual took apart a paint brush to use the metal band as a jumper in place of the meter. Metal band was placed phase to phase which blew up and burned up the existing meter socket. New meter has been installed. This is a major life safety issue.
ELE17-03175 Final9/21/20179/25/20179/25/2017 9:36:46 AMPPASS
Please call Heather at ###-#### for access. If you have any questions please call Jeremiah at ###-####. Thank you! Phone #: ###-#### Inspection requested via web by Dan Mitchell Ok final. Talked to electrician, 15a brkr was used on 12 ga wire to J-Box.
ELE16-02094 Final9/22/20179/25/20179/25/2017 8:55:07 AMAPASS
Megan-wife Phone #: ###-####-please call prior for access Ok final. Hottub disconnect is present, no hottub. GFI recept for tub works properly.
ELE17-02784 Electrical Rough-In9/24/20179/25/20179/25/2017 8:30:01 AMAPASS
Grid Inspection. Lockbox 2677 Phone #: ###-#### Inspection requested via web by Dean Gernaat Ok cover 2 offices, entry, and main work space ceilings.
ELE13-00343 ELE-Aging Inspection9/25/20179/25/20179/25/2017 7:10:03 AM FAIL
No final inspection requested at this time.
ELE17-02872 Final9/22/20179/25/20179/22/2017 10:38:48 AMACANC
David Forbes ###-#### Phone #: ###-#### >> Inspection requested via web by Samatha Solberg Inspection cancelled from web by: Samatha Solberg