ELE19-03198
| Electrical Rough-In | 9/25/2019 | 9/25/2019 | 9/25/2019 2:13:12 PM | P | PASS |
|
|
Ready for ceiling inspection. Thank You! Phone #: ###-#### Inspection requested via web by Kelly Felin Ok cover ceiling throughout. Waiting on 3 pendants to come in so boxes can be set in reception area.
|
ELE19-03582
| Electrical Rough-In | 9/24/2019 | 9/25/2019 | 9/25/2019 2:12:04 PM | P | PASS |
|
|
Greg Phone #: ###-#### Ok cover addition on E side of house.
|
ELE18-02610
| Final | 9/25/2019 | 9/25/2019 | 9/25/2019 1:38:47 PM | P | FAIL |
|
|
Cesar Phone #: ###-#### 1. 2 outside recepts need WR. 2. Spark rings needed in kitchen. 3. Horiz outlet under window needs changed to box to allow box fill. Blue shallow carlon used with holes drilled in back of box so excess wire could be pushed through. Also open ground at this location. Grounds were not inside box, they were pushed in wall.
|
ELE19-02926
| Electrical Rough-In | 9/24/2019 | 9/25/2019 | 9/25/2019 12:22:09 PM | A | PASS |
|
|
Call Brian at ###-#### 30 minutes prior and he will let you in. Rough in for basement bathroom. Phone #: ###-#### Inspection requested via web by sam petterson Ok cover main floor bath. Home owner will pull permit for doing their own floor heat.
|
ELE19-02235
| Final | 9/24/2019 | 9/25/2019 | 9/25/2019 12:21:17 PM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Kevin Perez Ok final
|
ELE19-03623
| Electrical Rough-In | 9/24/2019 | 9/25/2019 | 9/25/2019 11:33:55 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Don Conley Ok cover. 1. In unit 102, if opening in kitchen wall that looks into living has a countertop on final stage, we will need and outlet on each side of opening to serve countertop area. 2. Units 10 and 11 will need pop up counter recepts upon final. 3. Unit 100 is good.
|
ELE19-03365
| Final | 9/24/2019 | 9/25/2019 | 9/25/2019 10:24:25 AM | A | PASS |
|
|
the homeowner will be home in the morning after 8:30
you can call her at 208.859.9315 her name is Laura
thanks guys
Install complete per approved plans; the stamped and approved plans are on site; For any questions about the work done for this project, call Jed at ###-####; For any questions about the plans or design, call Ryan at ###-#### Phone #: ###-#### Inspection requested via web by Ryan King Ok final. Labels present, terminal blocks used inside panel for connections.
|
ELE19-01009
| Final | 9/25/2019 | 9/25/2019 | 9/25/2019 9:21:34 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Alan McCon college Power was off overnight due to incorrect equipt for application. 200a panel installed still using 100a meter base. 200a meter base was installed, 2 grd rods in place a long with water bond. People do occupy house at this time. p/s o/h n ok
|