FIR03-00333
| FIR-Aging Inspection | 9/26/2003 | 9/26/2003 | 9/26/2003 12:00:00 AM | | PASS |
|
|
talked to George and the work is still in progress 9/26/2003 8:21:53 AM
|
FIR03-00412
| INSP-Conference | 9/25/2003 | 9/26/2003 | 9/26/2003 12:00:00 AM | A | PART |
|
|
8:00 met with Ernie, John, and Dan about fire alarm requirements and need for approval of plans and testing prior to occupancy; exit signs will need to be installed per plans; fire sprinklers are approved as stated in sprinkler review comments 9/26/2003 8:19:06 AM
|
FIR03-00503
| INSP-Final Inspection | 9/25/2003 | 9/26/2003 | 9/26/2003 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 9/25/2003 at 2:03:29 PM. Contact: ###-####.
|
FIR03-00481
| INSP-Final Inspection | 9/25/2003 | 9/26/2003 | 9/26/2003 12:00:00 AM | A | PASS |
|
|
Scheduled by a contractor via Hello! on 9/25/2003 at 2:07:59 PM. Contact: ###-####.
|
FIR03-00104
| INSP-Alarm Testing | 9/25/2003 | 9/26/2003 | 9/26/2003 12:00:00 AM | A | FAIL |
|
|
smoke detectors need to be within 12 inches of deck in stairs and elevator machine room; need heat detectors added in elevator machine rooms; descriptor for first floor NAC detector and location has changed to update map also; need to test elevator recall and all flows and tampers; reverify phase reversal on fire pump; batteries not supervised; strobes in ADA sleeping rooms within 24 inches to be 177cd or lower strobe; need circuit breaker location on NAC's with lockout; tested location of devices on all living floors -okay; tested notification devices on all living floors - okay except ADA rooms; need updated maps and NFPA 72 forms when complete 9/26/2003 12:10:45 PM
|
BLD02-00090
| FIRE-Final Inspection | 9/25/2003 | 9/26/2003 | 9/26/2003 12:00:00 AM | A | FAIL |
|
|
john; Phone #: ###-#### Internet Inspection Request from: Darla Downs 9/26/2003 12:11:47 PM smoke seal on all rated doors; need floor drain, emergency lights and heat in fire pump room; stair signage; sprinkler heads fire proofed in stairs and elevator machine room; fire extinguishers require current inspection tag; see alarm permit for other items 9/26/2003 12:14:47 PM
|
BLD03-01629
| FIRE-Final Inspection | 9/26/2003 | 9/26/2003 | 9/26/2003 12:00:00 AM | P | PASS |
|
|
Scheduled by a contractor via Hello! on 9/26/2003 at 9:48:04 AM. Contact: ###-####.
|
FIR03-00565
| INSP-Final Inspection | 9/26/2003 | 9/26/2003 | 9/26/2003 12:00:00 AM | P | FAIL |
|
|
sam; Phone #: ###-#### Internet Inspection Request from: Darla Downs sprinkler system requires annual inspection; fire panel requires notification device; manual pull station and smoke detector above panel 9/26/2003 2:36:18 PM
|
FIR03-00512
| INSP-Final Inspection | 9/26/2003 | 9/26/2003 | 9/26/2003 12:00:00 AM | P | PASS |
|
|
|
FIR03-00331
| INSP-Final Inspection | 9/26/2003 | 9/26/2003 | 9/26/2003 12:00:00 AM | P | PASS |
|
|
|
FIR03-00095
| INSP-Final Inspection | 9/24/2003 | 9/26/2003 | 9/26/2003 12:00:00 AM | P | PASS |
|
|
###-#### don
|
FIR03-00096
| INSP-Final Inspection | 9/24/2003 | 9/26/2003 | 9/26/2003 12:00:00 AM | P | PASS |
|
|
###-#### don
|
FIR03-00097
| INSP-Final Inspection | 9/24/2003 | 9/26/2003 | 9/26/2003 12:00:00 AM | P | PASS |
|
|
###-#### don
|