Inspections for the day of: Tuesday, September 26, 2006.
Number of inspections: 16
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-03388 Electrical Rough-In9/26/20069/26/20069/26/2006 4:32:52 PMPPASS
Do not inspect until after 1:30 pm today. Work performed by Kyle Sharp.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz ok
ELE06-03388 Final9/26/20069/26/20069/26/2006 4:32:36 PMPPASS
Do not inspect until after 1:30 pm today. Work performed by Kyle Sharp.; Phone #: ###-#### Internet Inspection Request from: Matt Santacruz
ELE06-03586 Rough-In Permanent Service9/25/20069/26/20069/26/2006 4:12:45 PMPFAIL
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
wrong address and permit # told contr at site
ELE06-01764 Final9/25/20069/26/20069/26/2006 4:11:50 PMPFAIL
mike; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
corr. 210.52(C) needs outlet left side of cooktop also box fill right side 314.16
ELE06-02147 Final9/25/20069/26/20069/26/2006 3:47:36 PMPPASS
brian - call prior for access; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok
ELE06-03539 Rough-In Permanent Service9/26/20069/26/20069/26/2006 3:03:23 PMPPASS
Phone #: ###-#### Internet Inspection Request from: Daryl DeGranger/i p/s o/h new ok
ELE06-02426 Electrical Rough-In9/26/20069/26/20069/26/2006 2:13:57 PMPFAIL
Inspection of trenches for parking lot light poles.; Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot
u/g covered before inspection and shall be 24" where subject to vehicular traffic, 18 other location called
ELE06-01294 Final9/25/20069/26/20069/26/2006 1:50:09 PMANR
Phone #: ###-#### Internet Inspection Request from: Tye Tullis met with tye
ELE06-02020 Permanent Service9/25/20069/26/20069/26/2006 12:50:17 PMAPASS
idaho power will be opening transformer at 10am so we can pull in feeders, need inspection on service to energize. thanks; Phone #: ###-#### Internet Inspection Request from: ERIC p/s u/g new ok
ELE06-02014 Final9/25/20069/26/20069/26/2006 10:29:33 AMAPASS
eric; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok no card
ELE06-02353 Final9/26/20069/26/20069/26/2006 10:28:57 AMAPASS
ok
ELE06-03591 Rough-In Permanent Service9/25/20069/26/20069/26/2006 9:58:25 AMAPASS
allan; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley r/i ok needs switch and light in attic for equip, needs to address bathrm circuit 210.11(C)(3) p/s u/g new ok
ELE06-03582 Conference9/25/20069/26/20069/26/2006 9:15:17 AMADONE
Ray ###-#### needs to GEC to u/g water pipe, bond hot and cold, needs connectors for GEC
ELE06-03573 Final9/25/20069/26/20069/26/2006 8:42:31 AMAPASS
Phone #: ###-#### Internet Inspection Request from: Al Masi ok
ELE06-03539 Rough-In Permanent Service9/25/20069/26/20069/26/2006 8:16:31 AMACANC
Phone #: ###-#### Internet Inspection Request from: Daryl
called
ELE06-03565 Final9/22/20069/26/20069/25/2006 12:33:00 PMAPASS
mike - unit 912; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley ok