Inspections for the day of: Tuesday, September 26, 2006.
Number of inspections: 15
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorPat Lass
TitleELE-INSPECTOR
Phone #794-9478
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE05-02213 ELE-Aging Inspection9/26/20069/26/200610/3/2006 3:49:24 PM NR
suc
ELE06-03493 Electrical Rough-In9/26/20069/26/20069/26/2006 4:12:05 PMPPART
bob - 17th floor; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
2 walls by front desk ok
ELE06-03595 Electrical Rough-In9/26/20069/26/20069/26/2006 3:40:08 PMPPART
jeremy - underground ufer; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
electrode ok
ELE06-02344 Electrical Rough-In9/25/20069/26/20069/26/2006 3:11:49 PMPPART
chris - rebar for pool; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
partial bonding ok
ELE06-03192 Final9/26/20069/26/20069/26/2006 2:37:06 PMPPASS
john - call 1/2 hr prior for access; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
ELE06-03575 Temporary Service9/26/20069/26/20069/26/2006 1:30:02 PMPPASS
jared; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
T/S U/G Ok
ELE06-03124 Electrical Rough-In9/26/20069/26/20069/26/2006 1:08:11 PMPFAIL
###-#### james - call prior for access - early if possible; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
boxes overfilled no wirenuts on ground wires and bond metal box
ELE06-03544 Temporary Service9/25/20069/26/20069/26/2006 11:42:56 AMAPASS
george; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
T/S U/G Ok
ELE06-03585 Electrical Rough-In9/25/20069/26/20069/26/2006 11:30:43 AMAPASS
please call Jim w/Doherty 1/2hr before for access ###-####. Scheduled by Heather w/ Doherty; Phone #: ###-#### Internet Inspection Request from: Heather Packer
bathroom and garrage R/I Ok
ELE06-00121 Permanent Service9/25/20069/26/20069/26/2006 10:57:17 AMAPART
Phone #: ###-#### Internet Inspection Request from: joe wheeler
this is being taken over by the home-owner
ELE06-03592 Electrical Rough-In9/25/20069/26/20069/26/2006 10:53:26 AMAPART
4th floor North side, call Jim; Phone #: ###-#### Internet Inspection Request from: Jim Williams
five units 4th floor North side ok
ELE06-02690 Rough-In Permanent Service9/25/20069/26/20069/26/2006 9:26:59 AMAFAIL
ALEX HALL; Phone #: ###-#### Internet Inspection Request from: Sean DeLacy
isolate neutral and do bonding an attach an electrode to equipment grounding at disconnect on house.
ELE06-03575 Permanent Service9/25/20069/26/20069/26/2006 8:52:35 AMAFAIL
jerod; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
no main bonding jumper and 2 pole breaker doesn't seem to clamp onto the bussing securely
ELE06-03584 Electrical Rough-In9/25/20069/26/20069/26/2006 8:33:25 AMAPASS
Chad; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
ELE06-03465 Permanent Service9/26/20069/26/20069/26/2006 12:00:00 AMPCANC
cancel per kerry///blb If you could call about an hour before to make sure there is access I would appreciate it. Thanks; Phone #: ###-#### Internet Inspection Request from: Robert Murray