ELE13-02265
| Final | 9/26/2013 | 9/26/2013 | 9/26/2013 3:39:02 PM | P | FAIL |
|
|
Please call Gabe (###-####) 30min ahead. Phone #: ###-#### >> Inspection requested via web by Brad Girard NEMA 3 panels require listed Meyers hub for raceways to enter from top of raintight panels over bussing.
|
ELE11-02729
| ELE-Aging Inspection | 9/26/2013 | 9/26/2013 | 9/26/2013 3:16:11 PM | | DONE |
|
|
contractor waiting for homeowner
|
ELE11-00916
| ELE-Aging Inspection | 9/26/2013 | 9/26/2013 | 9/26/2013 3:14:28 PM | | DONE |
|
|
contractor still waitng for payment
|
ELE13-01658
| Electrical Rough-In | 9/26/2013 | 9/26/2013 | 9/26/2013 2:49:08 PM | P | PASS |
|
|
for ceiling in classroom C - Brandon Phone #: ###-#### rough-in ok cover ceiling grid
|
ELE13-02662
| Permanent Service | 9/25/2013 | 9/26/2013 | 9/26/2013 2:34:19 PM | P | PASS |
|
|
Someone will be there. IF you have any questions, please call Clay. Thank You. Phone #: ###-#### >> Inspection requested via web by Clay Morgan p/s u/g rec ok
|
ELE13-02649
| Rough-In Permanent Service | 9/26/2013 | 9/26/2013 | 9/26/2013 1:56:33 PM | P | NR |
|
|
Phone #: ###-#### >> Inspection requested via web by daniel bibikov Not ready
|
ELE13-01476
| Electrical Rough-In | 9/26/2013 | 9/26/2013 | 9/26/2013 1:33:29 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Celinda Winters rough-in ok cover walls
|
ELE13-02606
| Electrical Rough-In | 9/24/2013 | 9/26/2013 | 9/26/2013 1:33:23 PM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Celinda Winters rough-in ok cover walls
|
ELE13-02271
| Final | 9/25/2013 | 9/26/2013 | 9/26/2013 12:09:54 PM | A | PASS |
|
|
call for access - mike Phone #: ###-#### final ok for addition to house only
|
ELE13-02664
| Electrical Rough-In | 9/26/2013 | 9/26/2013 | 9/26/2013 10:56:06 AM | P | PASS |
|
|
treon Phone #: ###-#### rough-in ok cover walls
|
ELE13-02627
| Final | 9/25/2013 | 9/26/2013 | 9/26/2013 10:07:58 AM | A | PASS |
|
|
Contact: Brian Gee.... Also please call Jerry at ###-#### (30 minutes) before going so he can meet you there Phone #: ###-#### >> Inspection requested via web by Deb Gooden final ok
|
ELE13-02382
| Electrical Rough-In | 9/25/2013 | 9/26/2013 | 9/26/2013 9:37:41 AM | A | FAIL |
|
|
Phone #: ###-#### >> Inspection requested via web by Eric Schroeder Not all corrections completed
|
ELE13-02490
| Electrical Rough-In | 9/25/2013 | 9/26/2013 | 9/26/2013 9:13:07 AM | A | NR |
|
|
Please call Lynn with any questions, comments or concerns. Phone #: ###-#### >> Inspection requested via web by Lynn Proctor Not ready
|
ELE13-00899
| Electrical Rough-In | 9/25/2013 | 9/26/2013 | 9/26/2013 8:48:54 AM | A | FAIL |
|
|
Floor heat Phone #: ###-#### >> Inspection requested via web by Emmet Bushman NEC 110.3)B) Easy Heat, heat cable Listed equipment shall be install and used in accordance with manufactures instructions
|
ELE13-02262
| Final | 9/25/2013 | 9/26/2013 | 9/26/2013 8:04:21 AM | A | PASS |
|
|
JUSTIN early as possible- Thanks Phone #: ###-#### corrections done, final ok
|