ELE18-03674
| Conference | 9/25/2018 | 9/26/2018 | 9/26/2018 4:05:31 PM | P | PASS |
|
|
late afternoon call 20 mins. to meet // Brad or Anna ###-#### Phone #: ###-#### Discussed requirements for bed and bathroom addition, TR,WR, listed paddle fan box, smoke detectors, bathroom receptacle circuit, heat/fan/light combo circuit, equipment ground pigtails, pamphlet given
|
ELE18-03681
| Permanent Service | 9/26/2018 | 9/26/2018 | 9/26/2018 3:22:28 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Greg Traudt p/s o/h rec ok
|
ELE18-03695
| Rough-In Permanent Service | 9/26/2018 | 9/26/2018 | 9/26/2018 2:55:51 PM | P | PASS |
|
|
It Will Be Open Within The Hour Sorry Bud.. Phone #: ###-#### Inspection requested via web by jason shifflett Few ceilings not opened up due to ceiling heat cable still intact. Rough in ok cover p/s o/h rec ok
|
ELE18-03202
| Electrical Rough-In | 9/26/2018 | 9/26/2018 | 9/26/2018 2:07:01 PM | P | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Tyler Ridley Shop area and back office wall rough in ok cover
|
ELE18-03698
| Final | 9/26/2018 | 9/26/2018 | 9/26/2018 1:28:40 PM | P | FAIL |
|
|
Russ McCrea Phone #: ###-#### Inspection requested via web by Barbara Palmer Scope of work added 1 wall and a new coffee bar with a new sink. 210.8(B)- Receptacle outlets located with in 6' of a sink shall have GFCI protection.
|
ELE18-03575
| Rough-In Permanent Service | 9/25/2018 | 9/26/2018 | 9/26/2018 12:10:38 PM | A | FAIL |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn 210.52(A)- Walls 2' and wider shall have receptacle outlets installed for wall space. Up bed pocket door wall. 334.12- NM cable shall not be installed where subject to physical damage. Garage ceiling by man door hanging below ceiling. 334.30- NM cable supports not to exceed 4 1/2'. Garage ceiling HRs 6'+. 334.30- NM cable shall be secured with in 12" of front out door receptacle box.
|
ELE18-03574
| Rough-In Permanent Service | 9/25/2018 | 9/26/2018 | 9/26/2018 11:34:38 AM | A | PART |
|
|
Phone #: ###-#### Inspection requested via web by Bob Glenn Rough in ok cover p/s u/g n ok
|
ELE18-03693
| Temporary Service | 9/25/2018 | 9/26/2018 | 9/26/2018 10:55:17 AM | A | PASS |
|
|
Its hard to find, its actually on kendall, east of garden, west of 4554 Kendall.. call me if you need further instructions.. thanks, Bob Phone #: ###-#### Inspection requested via web by Bob Glenn t/s u/g n ok
|
ELE18-02295
| Electrical Rough-In | 9/25/2018 | 9/26/2018 | 9/26/2018 10:19:48 AM | A | PASS |
|
|
Rough in wall cover for the two classrooms 103 ; 110, and storage room 104. Phone #: ###-#### Inspection requested via web by Debby Pierce Rooms noted added restrooms and small storage room east end wall rough in ok cover.
|
ELE18-03681
| Permanent Service | 9/25/2018 | 9/26/2018 | 9/26/2018 9:27:49 AM | A | FAIL |
|
|
Hub snapped off the top of the meter. Replaced meter , riser , riser wire and grounding. Phone #: ###-#### Inspection requested via web by Greg Traudt 110.26- Minimum work space shall be provided for utility panel, 30" wide 36 deep. Move washer and dryer over.
|
ELE18-03695
| Rough-In Permanent Service | 9/26/2018 | 9/26/2018 | 9/26/2018 9:01:17 AM | A | NH |
|
|
This Is Ready For Inspection And Should Be Open After 830/ Call With Any Questions Or Concerns Thanks Dave ###-#### Dave Phone #: ###-#### Inspection requested via web by jason shifflett House locked. Recall when accessible.
|
ELE18-01875
| Final | 9/25/2018 | 9/26/2018 | 9/26/2018 8:46:00 AM | A | PASS |
|
|
Phone #: ###-#### Inspection requested via web by Todd Hall Final ok
|