Inspections for the day of: Tuesday, September 27, 2005.
Number of inspections: 17
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorJack Frank
TitleELE-INSPECTOR
Phone #794-1930
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE04-03063 ELE-Aging Inspection9/27/20059/27/20059/29/2005 8:06:21 AM PEND
called contractor will check on job and get back to me with info
ELE04-03191 ELE-Aging Inspection9/27/20059/27/20059/28/2005 1:00:26 PM DONE
ELE05-03507 Electrical Rough-In9/27/20059/27/20059/27/2005 4:30:08 PMPPART
###-#### - mike u/g ok
ELE05-03501 Final9/27/20059/27/20059/27/2005 3:49:43 PMPPASS
Scheduled by a contractor via Hello! on 9/27/2005 at 8:39:53 AM. Contact: ###-####. ok card signed
ELE05-03127 Electrical Rough-In9/27/20059/27/20059/27/2005 3:19:13 PMPPART
just for a/c ///john; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa r/i and conference ok
ELE05-03510 Final9/27/20059/27/20059/27/2005 2:04:30 PMPFAIL
steve ###-#### or ###-#### owner did work without permit and covered wiring before inspections, note I opened some boxes he did not have 6" free lenght, splices are not done to code, circuiting is wrong everything is on the bath rm circuit, outlet spacing, used screws inside plastic boxes, used white wire as equip grd,, correction posted for uncovering all wiring
ELE05-03490 Final9/27/20059/27/20059/27/2005 1:58:55 PMPPASS
Internet Inspection Request from: KENT JONES final for sign wiring ok
ELE04-03015 Final9/27/20059/27/20059/27/2005 1:02:35 PMPCANC
larry; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles see added r/i
ELE05-02154 Electrical Rough-In9/26/20059/27/20059/27/2005 11:06:42 AMAFAIL
Scheduled by a contractor via Hello! on 9/26/2005 at 10:27:45 AM. Contact: ###-####. r/i ok for u/g and outside soffits only cor. posted for thr rest of the work 300.4 nail plates 11/4", 314.16 box fill , 314.20 box not flush, 314.43 no screws or nails in plastic boxes, 210.7O, needs 3 way for stairs
ELE05-03484 Electrical Rough-In9/26/20059/27/20059/27/2005 10:25:10 AMAPASS
underground trench inspection ///gayle; Phone #: ###-#### Internet Inspection Request from: Barbara electrode ok for dirt cover
ELE05-03496 Electrical Rough-In9/26/20059/27/20059/27/2005 9:58:16 AMACANC
###-#### (cell) wk ###-#### - travis
called owner needs electrical contractor to do work this is rental property not the owner personal residence
ELE05-03490 Final9/24/20059/27/20059/27/2005 9:25:44 AMANR
After 9:00 would be best for access into the building. Call beforehand and I can meet you there. Internet Inspection Request from: KENT JONES called told contractor want needs to be done
ELE05-03224 Final9/26/20059/27/20059/27/2005 9:07:35 AMAPASS
henry ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie ok no card
ELE05-01869 Electrical Rough-In9/27/20059/27/20059/27/2005 8:43:30 AMAPART
underground; Phone #: ###-#### Internet Inspection Request from: Jim Williams u/g for lights in planter ok
ELE05-03496 Final9/26/20059/27/20059/27/2005 12:00:00 AMACANC
###-#### (cell) wk ###-#### - travis - doing ri first
ELE05-02267 Final9/27/20059/27/20059/27/2005 12:00:00 AMAPASS
ok
ELE04-03015 Electrical Rough-In9/27/20059/27/20059/27/2005 12:00:00 AMPPART
larry; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles pool bonding ok