Inspections for the day of: Wednesday, September 27, 2006.
Number of inspections: 14
Percentage of inspections complete: 100 %
Percentage of inspections not complete: 0 %
Contact Information
InspectorBob Reichert
TitleELE-INSPECTOR
Phone #794-1923
Permit NumberDescriptionReceivedRequestedCompletedAM/PMDisposition 
ELE06-03615 Conference9/27/20069/27/20069/27/2006 4:36:36 PMPDONE
MARK; Phone #: ###-#### Internet Inspection Request from: Darla Downs talked about requirements for grounding and service panel replacement
ELE06-02437 ELE-Aging Inspection9/27/20069/27/20069/27/2006 4:09:56 PM DONE
non electric sign standing, may be temporary
ELE06-02024 Final9/27/20069/27/20069/27/2006 3:44:09 PMPPASS
stephen; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr made, ok to final
ELE06-03260 Permanent Service9/27/20069/27/20069/27/2006 2:33:22 PMPPASS
Jason; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt p/s, exst meter pak, 2 meters, n, ok
ELE06-01341 Electrical Rough-In9/27/20069/27/20069/27/2006 2:20:29 PMPPART
dale; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles front area walls and hard lid ceilings ok to cover
ELE06-00892 Final9/27/20069/27/20069/27/2006 2:00:54 PMPPASS
dale; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr made, ok to final
ELE06-03552 Final9/27/20069/27/20069/27/2006 1:52:31 PMPCANC
This morning if possible. Thank you. If not this afternoon will work.; Phone #: ###-#### Internet Inspection Request from: Ryan Christensen see ri
ELE06-03552 Electrical Rough-In9/27/20069/27/20069/27/2006 1:52:03 PMPPASS
This morning if possible. Thank you. If not this afternoon will work.; Phone #: ###-#### Internet Inspection Request from: Ryan Christensen ri ok to cover, corrections made, need to fix p/s and call for again
ELE06-02921 Electrical Rough-In9/27/20069/27/20069/27/2006 1:10:25 PMPNR
Mike; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt elect was supposed to cancel, open boxes, securing mc cable, no lv wiring
ELE06-02542 Final9/26/20069/27/20069/27/2006 11:30:57 AMAPASS
stephen; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok to final
ELE06-01990 Permanent Service9/26/20069/27/20069/27/2006 9:36:33 AMACANC
kc; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley, wrong type inspection, see ri
ELE06-01990 Electrical Rough-In9/27/20069/27/20069/27/2006 9:34:22 AMAPART
kc; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley looked at gec, ok to pour, told owner to call after pour and we'll give the ok to cover, also need to bring in water pipe ground to panel, and center gec on stud, then we can give ok for power
ELE06-03532 Electrical Rough-In9/26/20069/27/20069/27/2006 9:03:28 AMAPASS
olga; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley corr made, ric ok
ELE06-03598 Permanent Service9/26/20069/27/20069/27/2006 9:00:24 AMAFAIL
bob; Phone #: ###-#### Pleae call for code Internet Inspection Request from: Cathy Chiles called, left corr notice, BCC address and job id sticker shall be posted,nec 352.30 rnc shall be securely fastened within 3' of termination, 250.64(B) gec shall be securely fastened to surface which carried, 250.50, 250.52(A)(1) water pipr shall be part of grounding electrode system, 110.12(A) unused openings shall be closed, 334.30 nm cable shall be supported within 12" of panel, 110.26(A)(2) min 30" work space shall be provided in front of sub-panel