ELE13-02194
| Final | 9/25/2013 | 9/27/2013 | 9/30/2013 10:13:59 AM | P | NH |
|
|
danny Phone #: ###-#### No return phone call
|
GCE13-00157
| GCE-Rough-In | 9/27/2013 | 9/27/2013 | 9/27/2013 4:43:17 PM | P | PASS |
|
|
Larry ###-#### Rough in ok cover p/s u/g n ok
|
GCE13-00158
| GCE-Rough-In | 9/27/2013 | 9/27/2013 | 9/27/2013 4:20:21 PM | P | PASS |
|
|
Larry ###-#### Rough in ok cover p/s u/g n ok
|
ELE13-00603
| Final | 9/27/2013 | 9/27/2013 | 9/27/2013 3:32:16 PM | P | PASS |
|
|
lucas - call 10 mins prior Phone #: ###-#### Final ok
|
ELE13-02243
| Final | 9/26/2013 | 9/27/2013 | 9/27/2013 3:14:56 PM | P | FAIL |
|
|
mike Phone #: ###-#### Dishwasher not set, Range and dryer recepticals need swapped, and kitchen and bathroom devices need covers
|
ELE13-02667
| Temporary Service | 9/27/2013 | 9/27/2013 | 9/27/2013 2:48:19 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Emmet Bushman t/s o/h n ok
|
ELE13-01719
| Final | 9/27/2013 | 9/27/2013 | 9/27/2013 2:30:17 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Rick Berry sign final ok
|
ELE13-01719
| Electrical Rough-In | 9/27/2013 | 9/27/2013 | 9/27/2013 2:29:43 PM | P | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by Rick Berry Penhouse, upper floor sign rough in ok
|
ELE13-02676
| Final | 9/26/2013 | 9/27/2013 | 9/27/2013 2:27:35 PM | A | PASS |
|
|
Larry Phone #: ###-#### Final ok
|
ELE13-02676
| Electrical Rough-In | 9/27/2013 | 9/27/2013 | 9/27/2013 2:27:16 PM | P | PASS |
|
|
Larry Phone #: ###-#### Front light, switch, and receptical outdoor rough in ok
|
ELE13-01972
| Final | 9/26/2013 | 9/27/2013 | 9/27/2013 2:13:39 PM | P | FAIL |
|
|
Ryan is contact. Thank you! Phone #: ###-#### >> Inspection requested via web by Chris Chesnut 210.8 All bathroom receptical outlets shall have GFCI protection. Powder baths. 210.52(A)(2) Any wall space 24" and wider shall have receptical outlet. Left of upstairs slider. 406.5 All receptical outlets shall have covers. Basement
|
ELE13-02683
| Rough-In Permanent Service | 9/26/2013 | 9/27/2013 | 9/27/2013 1:39:43 PM | A | FAIL |
|
|
The outside cans have not been wired yet because of the fire bonnets that I need Phone #: ###-#### >> Inspection requested via web by Neal Rumsey 800.24 Communication circuits shall compy with 300.4(G). Where ran through bosred hole with less than 1 1/4" to framing surface cables shall be protected from physical damage by nail plates.
|
ELE13-02577
| Electrical Rough-In | 9/26/2013 | 9/27/2013 | 9/27/2013 12:57:56 PM | A | PASS |
|
|
Wall Cover. Danny on site Phone #: ###-#### >> Inspection requested via web by Buster Bowen Offices located in N.E. corner. Wall rough in ok cover
|
ELE13-02678
| Electrical Rough-In | 9/26/2013 | 9/27/2013 | 9/27/2013 10:54:02 AM | A | PASS |
|
|
this is for walls and ceiling cover in this small space call steve with questions thanks Phone #: ###-#### >> Inspection requested via web by Don Lustig Walls and ceiling rough in ok cover
|
ELE13-02057
| Conference | 9/26/2013 | 9/27/2013 | 9/27/2013 10:33:08 AM | A | DONE |
|
|
Levi on site. Phone #: ###-#### >> Inspection requested via web by Buster Bowen Discussed 2 hr fire barrier for temporary feeders feeding fire sprinkler pumps. Maybe some support and strapping issues due to asbestos presence
|
ELE13-01617
| Permanent Service | 9/26/2013 | 9/27/2013 | 9/27/2013 9:30:26 AM | A | FAIL |
|
|
Robert Foster Phone #: ###-#### Grounding electode conductor shall not be ran through meter. 250.24- Grounding electode conductor shall terminate at the same bus bar as grounded conductor. 250.26- Main bonding jumper shall be installed. 334.30- NM cable shall be secured with in 8" of boxes.
|
ELE13-02643
| Rough-In Permanent Service | 9/26/2013 | 9/27/2013 | 9/27/2013 8:46:32 AM | A | PASS |
|
|
Phone #: ###-#### >> Inspection requested via web by George Pascua Rough in ok cover p/s o/h n ok
|